11kv 3MW Dummy Load Bank for Generator Test

Product Name: 11kv 3MW Dummy Load Bank for Generator Test
Warranty: 12 Months
Application: Hv Generator Set Testing
Dimension: 6058*2438*2591mm
Duty Cycle: Continuous
Cooling: Forced Air Cooling
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC11kV-3MW
Display Parameters
Voltage, Current, Power, Power Factr, Frequency
Rated Voltage
11kv
Max Load Power
3MW
IP Protection
IP55
Transport Package
Wooden Case
Specification
ISO9001: 2008
Trademark
Triumph Load
Origin
Shijiazhuang, Hebei, China
HS Code
9030390000
Production Capacity
5 Sets/Month

Product Description

Measuring Function
Steady-state Test: load power in rated range, measure generator steady-state 3 phase voltage, current, active power, reactive power, apparent power, power factor, frequency, and running time.
Control Mode
(1) Control Mode: local, remote or intelligent control(software) for choosing.
(2) Local Control: local control panel with several power steps, load or unload by switch on-off and read parameter values from measuring meter.
(3) Remote Control:through the switch in the remote control box, control the load over a long distance.
(4) Intelligent Control: through data processing software, realize all the test functions, display, record and manage the testing data, and generate curves, graphs and tables can be printed.
(5) Control Mode Interlock: with control mode switch, no matter chooses which mode, operation of other mode is invalid, avoid the clash.
 Intelligent Load Function
(1) Communication Mode: using photoelectric isolated RS485 communication serial port connect to PC, and with great anti-interference performance to make system control stable. Through converts like USB or RS232 realize communication protocol conversion.
(2) Load Mode: steady-state load (manual load, preset load and automatic load) and transient state load (instant load and instant unload).
(3) Manual Load: input power and power factor, and load according to the preset value.
(4) Preset Load: input generator related parameters, then choose the preset proportion from 0% 25%, 50%, 75%, 100% or other available order and calculate the power value automatically and realize rapid load.
(5) Automatic Load: set several load stages and duration, then complete the process according this stages automatically. Pause at any time or start to next stage in the load process.
(6) Parallel Test: several load banks work in parallel, the parallel test via software. Parameters of each set can be displayed in each meter and total parameter values can be displayed and recorded.
 Data Manage Function
(1) Real-time Monitor: through software display main parameter value, such as voltage, current, power, power factor, frequency and time.
(2) Data Collection Interval: the minimum steady-state data resolving time is 1 second, and the minimum transient data resolving time is 40μs.
(3) Stable Data Comparisons: the max value and min value of all the parameters in steady-state test are listed in software interface; it is convenient for user to compare.
(4) Data Save and Query: all test data are saved in the software, and according to generator set number easy to fast query in the history test data.
(5) Graphical Display: show real-time or history test data, and support to print curve and graph as follows:
1) Voltage, current, frequency and power curves in real-time; 2) voltage curve;
3) Current curve; 4) power curve; 5) frequency curve; 6) power factor curve;
(6) Test Report: display and support to print reports as follow:
1)Test report of generator set steady-state performance; 2)testing data report
(7) Data Format: all curves and graphs are outputted as".jpg"format, testing reports are outputted as".xls"format, and can be printed.
 Protection
(1) Overvoltage Protection: the input load voltage is over the safe threshold value, system unload automatically and give an alarm.
(2) Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.
(3) Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.
(4) Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.
(5) Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.
(6) Overload protection with fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.
(7) Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.
(8) Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.
(9) Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.
 Technical Parameter
System Parameter
Rating voltage/frequency 11kV, 3 phase 50Hz
Max Load Power  Resistive Load: 3000kW
Load Resolution Resistive Load: 7steps, 250KW,250kW,500kW,500kW,500kW,500kW,500kW
Power Factor 1
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External AC 3 phase 4 line, 415V/50Hz
Wire Connection Load bank input--Copper bar (star coupling "Y")
Control power input--Connector-bar
Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP55
Duty Cycle Continuous  
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions About 6058mm×2350mm×2591mm(L×W×H)
Operating Environment Parameter
Ambient Temperature -10ºC~+50ºC
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Xiguang
Fuse Chuantai
Alloy Resistor (self-developing)
Data Processing Software  (self-developing)

11kv 3MW Dummy Load Bank for Generator Test
11kv 3MW Dummy Load Bank for Generator Test
11kv 3MW Dummy Load Bank for Generator Test
11kv 3MW Dummy Load Bank for Generator Test
11kv 3MW Dummy Load Bank for Generator Test

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now