Rated Power: 5, 10, 15, 20, 50, 100, 200, 500, 1000kw
Rated Voltage: 220/380/400/415/690V
Power Factor: ±0.2-1
Duty Cycle: Continuous
Cooling: Forced Air Cooling
Control Mode: Manual/Remote/Software
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
Container AC load bank
Casing Structure
Permanent/Portable
Manufacturetype
OEM/ODM
Voltage Type
AC Single Phase/3 Phase
Color
Grey or as Required
Transport Package
Wooden Case
Specification
ISO9001: 2008
Trademark
Triumph Load
Origin
Shijiazhaung, Hebei, China
HS Code
9030390000
Production Capacity
10 Sets/Month

Product Description

Main Features of Containerized Resistive Load Bank for Genset testing
 
Accumulating more than twenty years experience of load bank design and manufacture, optimizing and innovating to the imported types, Kaixiang formed into multi-type, multifunction and multi-series products that can meet the users who have different needs. The excellent cost performance ratio of products is suitable for domestic & international users.
New generation load bank have been become the industry guider due to the larger power and advanced capability and the most advanced design and technology.
System Parameter
Rating voltage/frequency 400V 3 phase 4 line,line voltage: 400V, phase voltage: 230V, 50Hz
Max Load Power  Resistive Load: 5000kW
Load Resolution Resistive Load: 29steps,
10kW,20kW,20kW,50kW,100kW,
200kW,200kW,200kW,200kW,200kW,200KW,200kW,200kW,200kW,
200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW,
200kW,200kW,200kW,200kW,200kW,200kW
Power Factor 1
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External 380V 3 phase 4 line, line voltage: 380V, phase voltage: 220V, 50Hz
Wire Connection Load bank input--Copper bar (star coupling "Y")
Control power input--Connector-bar
Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP54
Duty Cycle Continuous  
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions About 7000mm*2350mm*2591mm(L×W×H)
Operating Environment Parameter
Ambient Temperature -10ºC~+50ºC
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Schneider
Fuse Miro
PLC Siemens
Alloy Resistor (self-developing)
Data Processing Software  (self-developing)
 
The Main Application Of The Load Bank
 
Factory testing of engines generator sets
To reduce "wet stacking" problems
Periodic exercising of stand-by engine generator sets
Load testing of AC power source
On-site acceptance testing
UPS system testing and maintenance
New projects inspection and battery system maintenance
Load optimization in prime power applications
 
Main 10 Technology Advantages
Kaixiang company is in leading position in generator set testing and maintenance industry, besides general functions, its load bank has following unique advantages:
1. Standard Testing Function: The load bank can do stable test, transient test, and realize functions, such as setting, fluctuation, instant load, and instant unload.
2. Super Power Load: high load power density, large capacity of single set, parallel running to finish super power testing, and realize tens of megawatts of power loading.
3. Accurate Data: with high precision data collection module and measuring meter, related equipment has passed the certification by CMA (China Metrology Accreditation) qualification testing institution, and ensure the reliability of data.
4. Flexible Control Mode: based on different using habit, several control mode as following can be choosed, local panel operation, remote box controlling, and intelligent software. 
5. Intelligent Load: after setting generator rated power in software, system realize rapid loading through preset proportion, automatically and continuously load multiple power value and common tests, like stepping, full load, and over load, so that improve working efficiency.
6. High Efficiency Data Management: display real-time testing data, generate form, curve graph or report automatically, also can put data into storage. According to generator set No. set up testing file, support to query at any time, and improve data management efficiency.
7. Comprehensive Protection Function: multiple protection, like over temperature, smoke. When in danger, automatically terminate the test and give alarm to protect safety of personnel and equipment.
8. Stable Running: with the latest generation control module as the core, a sharp rise in system response speed and anti-interference performance, avoid function failure in complex electrical environment, and ensure system running stably and reliably. 
9. New Load Bank Technology: using the international advanced AC load bank technology, overcome the old water bank defects, such as bear bumpy, unable to use when go to sea, realize Mooring Trial and Sea Trail, and simulate the real working condition of generator running.  
10. Mature Manufacturing Technology: load element using excellent anti-corrosion materials, waterproof insulation container packaging, suitable for adverse environment such as ocean. Internal layout is reasonable, air channel is clear, rapid heat emission, and satisfy continuous working need.
 
What We Can Do
1. Professional technical team with more than 20 years design experience.
2. Customized technical solutions meet customer's individual requirements.
3. Skilled workman insure the reliable assembly technology.
4. Strict inspection procedures throughout the whole production flow.
5. Prompt delivery & custom clearance make sure the customers receive the goods on time.
6. Perfect after sales service create good user experience.
7. Reliable quality & competitive price help customers to maximize profits.
8. Timely feedback save valued time for the customer.
9. Humanized management system build homelike work atmosphere.
10. Continuous devote to public welfare undertakings strive for harmonious society.
5MW 3 Phase Dummy Load Bank for Genset Testing
5MW 3 Phase Dummy Load Bank for Genset Testing
5MW 3 Phase Dummy Load Bank for Genset Testing
5MW 3 Phase Dummy Load Bank for Genset Testing
5MW 3 Phase Dummy Load Bank for Genset Testing



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now