6.6kv 2MW Load Bank for Gas Turbine Generator Testing

Rating Voltage: 6.6kv, 3 Phase /50Hz
Rated Load Power: 2MW
Load Step: 100kw,200kw,400kw, 500kw,800kw
Power Factor: 1
Cooling: Forced Air Cooling
Dimension: 6058*2350*2591mm
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC6.6KV-2000kW
Trademark
Triumph Load
Origin
China
HS Code
9030339000
Production Capacity
10sets/Month

Product Description

Introduction

(1) According to the special requirements of users on site, in the agreement the technical standards of 6.6KV 6MW Load Bank for HV Generator Testing  (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.

 

(2) 6.6KV 3MW Load Bank for HV Generator Testing  consists of 1 sets of 3000kw load bank. The system is made up of two parts of measurement & control and load, mainly including the high voltage dry type AC load bank, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote control box and PC software and so on.

 

(3) 6.6KV 3MW Load Bank for HV Generator Testing, which is of independent research and development of electricity load test equipment by our technology, combining high voltage dry type load module with the automatic measurement and control module, with excellent insulation protection performance, itcan directly detect high voltage generator output power and load capacity (no need a step down transformer), full load and overload test.

The system can be used with a computer to realize the intelligent control, automatically completing the special test to all electrical parameters of generating set and generating tables, graphs, and supporting the print, release from the cumbersome manual operation to provide scientific and efficient detection means for the large power high voltage generating sets.

 

(4) All the schematic diagrams of this agreement are for reference only please in kind prevail.  

 

6.6KV 3MW Load Bank for HV Generator Testing

Rating Voltage/Frequency

6.6KV /50Hz

Rated Load Power

Resistive load: 2MW

Installed Capacity

Resistive load: 2MW

Load Step

Resistive load: 5 steps, 100kw,200kw,400kw, 500kW,800kw  min step: 100kW

PF(Power Factor)

1

Load Tolerance  (each step)

±5%

Load Tolerance(overall)

±3%

Display Precision

0.5 class

Control Power

3 phase 4 wire 380V,50Hz

Wire Connection

Load power supply input--Copper bar (star coupling)

Control power supply input--Connector-bar

Insulation

F

Max Protection Grade

IP55

Duty Cycle

Continuous  

Cooling

Forced air cooling,Horizontal inlet air,Vertical cooling

Aeration

About 160,000 cubic meters per hour

Casing Structure

Container, with a ladder, air inlet and outlet with mesh enclosure and protection door

Transportation

Hoisting, there are lifting lug in top of casing

Casing Color

Grey(RAL7035)or as per customer's requirement

Dimension

About 6058mm×2350mm×2591mm(length*width*height)

Weight

About 6500kg

Operating Environment Parameter

Workplace

Outdoor

Ambient Temperature

-20ºC~+50ºC

Relative Humidity

≤95%

Altitude

≤2500 meter

Atmospheric Pressure

86~106kPa

Space Required

About 14.77 square meter

Ground load-bearing requirements

About 406kg/square meter

Aeration Distance

3-5meters no obstacle from air inlet, more than 3meters no obstacle from air outlet

Safe Working Distance

For the convenience of personnel to enter, there should no obstacles 3 meters in front of control room and no obstacles 2 meters in front of maintenance room

Brands of Main Components

Contactor

Imported brand or Chinese brand

Fuse

Chuantai

Alloy Resistance

Kaixiang(self-developed)

Data Processing Software

Kaixiang(self-developed)


6.6kv 2MW Load Bank for Gas Turbine Generator Testing
6.6kv 2MW Load Bank for Gas Turbine Generator Testing
6.6kv 2MW Load Bank for Gas Turbine Generator Testing
6.6kv 2MW Load Bank for Gas Turbine Generator Testing
6.6kv 2MW Load Bank for Gas Turbine Generator Testing
6.6kv 2MW Load Bank for Gas Turbine Generator Testing
6.6kv 2MW Load Bank for Gas Turbine Generator Testing
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now