• 1600kw Load Bank to Test Generator
  • 1600kw Load Bank to Test Generator
  • 1600kw Load Bank to Test Generator
  • 1600kw Load Bank to Test Generator
  • 1600kw Load Bank to Test Generator
  • 1600kw Load Bank to Test Generator

1600kw Load Bank to Test Generator

Conditions
of Use:
Trailer Type, Marine, Land Use
Usage: Standby Unit, Common Units
Output Type: AC Three Phase
Cooling
Method:
Air Cooled
Installation
Method:
Fixed
Generator
Type:
Diesel Generator
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC415-1600KW
Voltage
415V
Power
1600kw
Power Factor
1
Min Step
1kw
Frequency
50Hz/60Hz
Communication
RS485, RS232
Control
Local and Remote
Container
20FT
Warranty
12 Months
Transport Package
Container
Specification
ISO
Trademark
Triumph Load
Origin
China
HS Code
90303900
Production Capacity
300 Set Per Year

Product Description

Rated Voltage: 11KV, 3phase, 50HZ/60HZ, Load Type: Resistive Load. Power Factor: 1. Duty Cycle: Continuous. Cooling Type: Forced air  cooling. Dimension: 6058mm*2350mm*2591mm. Control Load Method: manual by load switch or PC. Min Load Steps: 1kW. Application Place: Outdoor. Load Resolution: 3%. PLC: Siemens. 

1600kw Load Bank to Test Generator1600kw Load Bank to Test Generator1600kw Load Bank to Test Generator

1. Main features and advantages

1. Power consumption components adopt special alloy resistor, high-temperature resisting, small thermal drift, safe and reliable. Running temperature is 1/3 of design temperature.

2. Industrial heavy duty blower, horizontal inlet, vertical exhaust, low noise.

3. Weather-proof structure, suitable for abominable environment.

4. Multiple control mode: (1)Local panel control, (2)Remote control box/cabinet(3) Intelligent control(by PC software)

5. Multiple protection function: overvoltage, overcurrent, overheat, low over blowing rate, blower overheat, blower phase sequence reverse protection, smoke alarm etc.

6.Integrated design, easy to installation. 

2. Application

Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment

1600kw Load Bank to Test Generator
1600kw Load Bank to Test Generator

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now