• 2000kVA Resistive Inductive Load Bank for Generator Testing
  • 2000kVA Resistive Inductive Load Bank for Generator Testing
  • 2000kVA Resistive Inductive Load Bank for Generator Testing
  • 2000kVA Resistive Inductive Load Bank for Generator Testing
  • 2000kVA Resistive Inductive Load Bank for Generator Testing
  • 2000kVA Resistive Inductive Load Bank for Generator Testing

2000kVA Resistive Inductive Load Bank for Generator Testing

Rated Power: 2000kVA
Rated Voltage: 400V
Frequency: 50Hz or 60Hz
Load Tolerance (Overall): ±3%
Load Tolerance (Each Step): ±5%
Communication Interface: RS485, RS232
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC400-2000KVA
Enclosure Protection Class
IP55
Cooling
Air Forced Cooling
Insulation Grade
F
Ambient Temperature
-20 to +50 Degree
Transport Package
Self Containered
Specification
ISO9001: 2008
Trademark
Triumph Load
Origin
Hebei Province, China
HS Code
90303900
Production Capacity
150sets/Year

Product Description

AC 400V 2000KVA Electronic Load Bank
PF=0.8; Apparent power: 2000KVA,  400VAC, 50Hz, 3phase 4wire. 
Introduction:
Resistance/inductance/capacity/Portable Intelligent load bank 
Intelligent AC load bank main used to test the capability and aging degree for high-power ups on-line, inverter, switch power and diesel generator set for electric power, telecom department and manufacturer. It can ensure the reliability of constant power charge that adopts uniformly stepped power input, energy consumption work model and forced air-cooling model. It is of high power density, no red hot phenomenon and automatic protection function overheated. It can't be overheated and broken when the fans stop working. The complete machine can be operated simply and maintain convenient that adopts module design. It can test voltage and current according to client's request, and provide scientific test measures for high-power AC equipment.
Main functions 
1. Users can set adjustable discharge power according to capability parameter and test request.
2. Voltage and current value can be displayed with multi-functional digital meter.
3. AC load bank is of all kinds of specifications and series, and include resistance, inductive and capacitive load.
4. Two or more Intelligent AC Load Bank can operate in parallel.
5. It can make stable state test. 
6. Remote control by software.
7. Testing data can be saved or transferred by RS485, data can form curve, to be printed. 
Function options 
Intelligent AC Load Bank has two control patterns: position machine software control and local panel control
Intelligent AC load bank (LED): multi-function digital special meter of 0.5 step can be test and display: AC voltage, current, active power, power factor and frequency. It can communicate with PC via RS485 interface.
Intelligent AC load bank (LCD): Special LCD meter display: AC voltage, current, active power, power factor and voltage frequency. It is of the harmonic analysis function of 1-40 times, and can communicate with PC via RS485 interface.
Technical parameters of AC 400V 2000KVA Electronic Load Bank

Rating Voltage/Frequency

AC 400V,50Hz/60Hz

Compatible voltage

Resistive Load: 1600kW, Inductive load: 1200KVAR 

Load Step

Resistive Load:
1   pcs Selector Switch :0.5-5kW,
18 pcs Button   Switch :
5, 10, 10, 10, 20, 20, 20, 50, 50, 100, 100, 100, 100, 200, 200, 200, 200, 200kW;
 
Inductive Load:
1   pcs Selector Switch :0.5-5kVAR,
15 pcs Button   Switch :
5, 10, 10, 10, 20, 20, 20, 50, 50, 100, 100, 200, 200, 200, 200kVAR;

Power Factor

0.8-1.0

Load Tolerance(each step)

±5%

Load Tolerance(overall)

±3%

Display Precision

0.5 class

Control Power Supply

AC380V/50Hz Three Phase  Four Wire

Wire Connection

Three-phase four-wire

Communication Interface

RS-485, RS-232

Duty Cycle
Continuous

Cooling

Forced air cooling, Vertical airflow, Horizontal inlet air, Upward cooling

Dimension

About  6058mmx2438mmx2591mm(Length *Width*Height)

Weight

About 13000kgs 

Ambient Temperature

-10ºC~+50ºC  (14°F~122°F)

Relative Humidity

≤95%

Altitude

≤2500 meters

Atmospheric Pressure

86~106kPa
2000kVA Resistive Inductive Load Bank for Generator Testing
2000kVA Resistive Inductive Load Bank for Generator Testing
2000kVA Resistive Inductive Load Bank for Generator Testing
2000kVA Resistive Inductive Load Bank for Generator Testing
2000kVA Resistive Inductive Load Bank for Generator Testing
2000kVA Resistive Inductive Load Bank for Generator Testing

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now