AC440-2500KVA
Voltage
400V,440V,480V,690V
Capacity
2500kVA
Resistive
2000kw
Reactive
1500kvar
Power Factor
0.8
Frequency
50Hz, 60Hz
Control
Local and Remote
Communication
RS485, RS232
Certification
Ce
Warranty
RS485, RS232
Transport Package
Container
Specification
ISO
Trademark
Triumph Load
Origin
China
HS Code
90303900
Production Capacity
300 Units

Product Description

Rated Voltage: 440V, 3 phase 4 wire, 50HZ. Apparent Power: 2500KVA, Resistive Power: 2000KW, Inductive Power: 1500KVAR. Load Type:Resistive Inductive Integrated. PF: 0.8. Cooling: Forced air cooling. Duty Cycle: Continuous. Dimension: 6058*2350*2591mm. Protection: IP55. Load Resolution: 1kW/1KVAR. Control Mode: Manual/remote/PC. Display Parameters: voltage, current, power, PF, frequency. Guarantee: 1 year. 

440V 2500kVA Load Bank for Generator Test440V 2500kVA Load Bank for Generator Test

 

Introduction of 2500KVA Resistive Reactive Load Bank(PF 0.8):

Resistance/inductance/capacity/Portable Intelligent load bank 

Intelligent AC load bank main used to test the capability and aging degree for high-power ups on-line, inverter, switch power and diesel generator set for electric power, telecom department and manufacturer. It can ensure the reliability of constant power charge that adopts uniformly stepped power input, energy consumption work model and forced air-cooling model. It is of high power density, no red hot phenomenon and automatic protection function overheated. It can't be overheated and broken when the fans stop working. The complete machine can be operated simply and maintain convenient that adopts module design. It can test voltage and current according to client's request, and provide scientific test measures for high-power AC equipment.

Main functions of 2500KVA Resistive Reactive Load Bank(PF 0.8)

1. Users can set adjustable discharge power according to capability parameter and test request.

2. Voltage and current value can be displayed with multi-functional digital meter.

3. AC load bank is of all kinds of specifications and series, and include resistance, inductive and capacitive load.

4. Two or more Intelligent AC Load Bank can operate in parallel.

5. It can make stable state test. 

6. Remote control by software.

7. Testing data can be saved or transferred by RS485, data can form curve, to be printed. 

Function options of 2500KVA Resistive Reactive Load Bank(PF 0.8)

Intelligent AC Load Bank has two control patterns: position machine software control and local panel control

Intelligent AC load bank (LED): multi-function digital special meter of 0.5 step can be test and display: AC voltage, current, active power, power factor and frequency. It can communicate with PC via RS485 interface.

Intelligent AC load bank (LCD): Special LCD meter display: AC voltage, current, active power, power factor and voltage frequency. It is of the harmonic analysis function of 1-40 times, and can communicate with PC via RS485 interface.

440V 2500kVA Load Bank for Generator Test
440V 2500kVA Load Bank for Generator Test
440V 2500kVA Load Bank for Generator Test



 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now