Rating Voltage: 400VAC, 3pH, 50Hz/60Hz
Rated Load Power: 5000kVA
Power Factor: 0.8
Load Tolerance (Each Step): 5%
Load Tolerance(Overall): 3%
Insulation: F
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC400-5000kVA
Cooling
Forced Air Cooling
Transportation
Hoisting
Max Protection Grade
IP55
Dimension
9000mm*2438mm*2591mm
Transport Package
Container Type
Specification
ISO9001: 2008
Trademark
triumph load
Origin
Shijiazhuang, Hebei, China
HS Code
9030390000
Production Capacity
100sets/Year

Product Description

Application
Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
The RL Series Resistive-Reactive Load Banks offers a 0.80 power factor load and is designed for testing large generators, switchgear, transformers and UPS systems. The structural skid with fork lift pockets allows for portability and is ideal for shipyards, power plants, OEMs and data centers. The RL Series is the perfect solution for regularly scheduled maintenance testing and commissioning of mission-critical standby emergency power systems where rated kVA, rated power factor and rated current testing is required.
 
System Parameter
Rating voltage/frequency AC 3 phase 4wire, 400V, 50HZ/60Hz
Max Load Power Apparent Power: 5000kVA
Resistive Load: 4000kW
Inductive Load: 3000kvar
Load Resolution Resistive Load: 28 steps,1,2,2,5,10,10,20,50,100,19*200kW
Inductive Load: 23 steps, 1,2,2,5,10,10,20,50,100,14*200kvar
Power Factor 0.8
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan Control Power AC 3 phase 4 wire, 380V/50Hz
Wire Connection Load bank input--Copper bar (star coupling "Y")
Control power input--Connector-bar
Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP55
Way of Working Continuous Working
Cooling Forced air cooling, horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Transportation Hoisting, there are lifting lug in top of casing
Color RAL7032
Dimensions About 9000mm*2438mm*2591mm(L×W×H)
Weight About 16000kg
Operating Environment Parameter
Ambient Temperature -10ºC~+50ºC
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Schneider
Fuse DELIXI
MCU Infineon
Alloy Resistor (self-developing)
Data Processing Software (self-developing)
5000kVA Resistive Inductive Load Bank for Genset Test
5000kVA Resistive Inductive Load Bank for Genset Test
5000kVA Resistive Inductive Load Bank for Genset Test
5000kVA Resistive Inductive Load Bank for Genset Test
5000kVA Resistive Inductive Load Bank for Genset Test
5000kVA Resistive Inductive Load Bank for Genset Test
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now