• China Brand Load Bank 2500kVA Generator Testing Loadbank
  • China Brand Load Bank 2500kVA Generator Testing Loadbank
  • China Brand Load Bank 2500kVA Generator Testing Loadbank
  • China Brand Load Bank 2500kVA Generator Testing Loadbank
  • China Brand Load Bank 2500kVA Generator Testing Loadbank

China Brand Load Bank 2500kVA Generator Testing Loadbank

Type: Electrical Performance Testing
Maxcapacity: >1000KN
Accuracy Grade: 0.5
Load Way: Electronic Load
Loading Method: Dynamic Load
Display: Digital
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC690-2500KVA-RL
Control
Computer Control
Weight
>2000Kg
Power Source
AC380V
Oil Cylinder Position
No
Voltage
AC690V
Frequency
50Hz
Resistive Power
2000kw
Inductive Power
1500kvar
Apparent Power
2500kVA
Insulation Grade
F Class
Cooling
Forced Air Cooling, Horizontal Inlet Air, Upward C
Protection Class
IP54
Dimension(W*D*H)
6000*3000*3300mm
Transport Package
Container
Specification
6000*3000*3300mm
Trademark
Triumph Load
Origin
Hebei, China
HS Code
9030339000
Production Capacity
10000 Sets/ Year

Product Description

China Brand Load Bank 2500KVA Generator Testing Loadbank

 

1.Product Introduction

China Brand Load Bank 2500KVA Generator Testing Loadbank

This machine is mainly used for the national grid, research institutes, national defense, electricity, telecommunications, railways, instrumentation, universities and other areas of diesel generator sets, power online UPS, inverters, switching power performance testing, aging and other occasions. This machine has a variety of control methods, either stand-alone operation, but also with the same series of load and machine. Optimized for power input segmented to adapt to different loads and different power factor requirements.

 

2. China Brand Load Bank 2500KVA Generator Testing Loadbank System Chart

China Brand Load Bank 2500kVA Generator Testing Loadbank

3. China Brand Load Bank 2500KVA Generator Testing Loadbank Working Environment

Altitute:≤2500m

Temperature:-10°C~50°C

Humidity:≤95%RH

Working Mode:Continuous work(>6hours continuous long-term work per day)

 

4. China Brand Load Bank 2500KVA Generator Testing Loadbank Technical Specifications 

System Parameters

Rated Voltage 

and Frequency

AC three-phase four-wire 690/400V, 50/60Hz 

Load Rated Power

Resistive load: 2000kW, inductive load: 1500kvar (50Hz), apparent power: 2500kVA

(When the input voltage is below the rated voltage, load the actual power by 

Ohm's law descending)

Maximum Load Power

When 690V, 50Hz, resistive load: 2002 kW, inductive load: 1500kvar

Load Step

Resistive Load: 1,3,6,12,24,48,96,96,192*6 steps (Unit: kW)

Three phase unbalance resistive load: 12,24,48,96,192,192 (Unit: kW)

Inductive load: 1,2,2,5,10,10,20,50,100,100,200*6 steps. (Unit: kvar)

Power Factor

0.8 (0.1 ~ 1 adjustable)

Load Accuracy (per file)

± 5%

Load Accuracy (whole)

± 3%

Display Accuracy

0.5

Control Power

External AC three-phase four-wire 380V/50Hz, 50kW

Wiring

Load Power Input - copper (Manual Star - Delta Connection conversion)

Control power input - terminal block

Wiring Port Design

Allow sufficient space to ensure that users can easily access the load cables.

External load penetrating openings in the cables after the cables have sufficient 

waterproof capability, and sufficient mechanical strength.

Communication Interface

RS485, RS232

Communication Protocol

Modbus

Insulation Class

Class F

Protection Class

IP54 (save state)

Work

Continuous work

Cooling

Forced air, side air intake on the wind

Chassis construction

Container package, with up to the top of the ladder, with inlet and outlet 

grilles and door protection

Transport

There bearing hanging hole, in line with lifting and transport conditions.

Chassis Size

Approximately 6000mm × 3000 mm × 3300mm (L × W × H)

Weight

Approximately 18000kg

Work environment parameters

Workplace

Outdoor work

Operating Temperature

- 25 ºC ~ + 6 0 ºC (lower limit of the instrument's temperature-10 ºC)

Relative Humidity

≤ 95%

Altitude

≤ 2500m

Atmospheric pressure

86 ~ 106kPa

 

5. China Brand Load Bank 2500KVA Generator Testing Loadbank Overall Appearance    
China Brand Load Bank 2500kVA Generator Testing Loadbank

China Brand Load Bank 2500kVA Generator Testing Loadbank
China Brand Load Bank 2500kVA Generator Testing Loadbank

6.More Pictures of AC Load Bank Application for Data Center
China Brand Load Bank 2500kVA Generator Testing Loadbank
China Brand Load Bank 2500kVA Generator Testing Loadbank

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now