Basic Info
  • Model NO.: AC380-1500KW
  • Rating Voltage: 380VAC/50Hz
  • Control Power: 3 Phase 4 Wire 380VAC/50Hz
  • Control Mode: Manual, Remote, Software
  • Max Protection Grade: IP55
  • Workplace: Outdoor
  • Specification: ISO9001: 2008
  • HS Code: 9030390000
  • Rated Load Power: Resistive Load: 1500kw
  • Power Factor: 1
  • Duty Cycle: Continuous
  • Cooling: Forced Air Cooling by Fan
  • Casing Structure: Container, with a Ladder, Air Inlet and Outlet Wit
  • Trademark: Triumph load
  • Origin: Shijiazhuang, Hebei, China
Product Description

Functions
1)      User could load any power within rated power, can test stable state three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency, running time of generating set.
2)      Whether load/unload by local control panel or by PC software control, user can pre-set the power then press the master load button.
3)      Control mode: user can choose local control, remote control or intelligent control (PC control)
4)      Local manual control: there is local control panel in load bank, with multi load steps, min load steps 1kW, controlled by buttons.
5)      Remote control: With remote controller box connected to load bank by control cable.
6)      Intelligent control: user can control load bank by data processing software of PC to make automatic load/unload, display, record and manager the test data, form curve, graph and can be printed.
7)      Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.
8)      With data processing software, could form curve of current, active power, reactive power, apparent power, power factor, frequency and can be printed.
9)      One-key load/unload: user can load or unload with one key easy to control.
10)   3 line LED multi-function meter display.

Data Processing Software Functions
1)      Communication type: through RS232, RS485 or USB interface.
2)      Load mode: manual load or automatic load.
3)      Manual load: input power and power factor.
4)      Automatic load: User can set several periods of power and time, and in turn of 0%→25%→50%→75%→100% or 110%, etc to make automatic load testing.
5)      Parallel testing: when several load banks parallel working, parameters of each load bank can be displayed and recorded, so do the final parameters of paralleling working.
6)      Real-time parameter: Current, voltage, power, power factor, frequency, time, etc could be displayed by software.
7)      Safety monitoring: User can know the working conditions of load bank through software indicating light. When in abnormal stop protection, software will indicate the reasons of stopping.
8)      Data collection interval: the min saving interval is 2 seconds.
9)      Data saving and in query: testing data could be saved in software, user can query at any time.
10)   Data display: it could display real-time data and history data; user can print voltage, current, frequency, power graphs and charts.
11)   Charts and graphs are output in format of JPG while testing data output in Excel format, and all can be printed.

Protection
(1) User can press the emergency stop button in the panel to unload immediately when the load bank is abnormal while working.
(2) Over-load: Automatic load dump and give alarm when voltage is over safety thresholds.
(3) Over-heat protection: Automatic load dump and give alarm when temperature is over safety thresholds.
(4) Short Circuit Protection: Fuse could avoids damage to equipment when short circuit or current overload.
(5) Fan protection: Machine could not do load testing before working power of fan is on.
(6) The machine will unload and give alarm when any fan is abnormal or with insufficient air volume, etc.
(7) When control power cable in wrong connections, 3 phase fans can also work in good conditions.
(8) Protection button: there are some protection buttons can be switched off when false alarm or for special requirements. 

Technical Parameter

AC380-1500kW Intelligent Load Bank
Rating Voltage/Frequency380AC/50Hz/60Hz, 3 phase 4 wire, 220V each phase
Rated Load PowerResistive load: 1500kW
Installed CapacityResistive load: 1500kW
Load StepResistive load: 14 steps, 1kw,2kw,2kw,5kw,10kw,20kw,20kw,50kw,100kw,200kw,200kw,200kw,200kw,500kw min step: 1kW
PF(Power Factor)1
Load Tolerance  (each step)±5%
Load Tolerance(overall)±3%
Display Precision0.5 class
Control Power3 phase 4 wire 380V/50Hz
Wire ConnectionLoad power supply input--Copper bar (star coupling)
Control power supply input--Connector-bar
InsulationF
Max Protection GradeIP55
Duty CycleContinuous
CoolingForced air cooling,Horizontal inlet air,Vertical cooling
AerationAbout 160,000 cubic meters per hour
Casing StructureContainer, with a ladder, air inlet and outlet with mesh enclosure and protection door
TransportationHoisting, there are lifting lug in top of casing
Casing ColorGrey(RAL7035)or as per customer's requirement
DimensionAbout 6058 mm×2438mm×2591mm(length*width*height)
WeightAbout 1700kg
Operating Environment Parameter
WorkplaceOutdoor
Ambient Temperature-10ºC~+50ºC
Relative Humidity≤95%
Altitude≤2500 meter
Atmospheric Pressure86~106kPa
Space RequiredAbout 14.77 square meter
Ground load-bearing requirementsAbout 406kg/square meter
Aeration Distance3-5meters no obstacle from air inlet, more than 3meters no obstacle from air outlet
Safe Working DistanceThere must be isolation lairage 1 meter from load bank, and when load bank is working, no person allowed in 3-5 meter from load bank
Brands of Main Components
ContactorSchneider
FuseDELIXI
Alloy ResistanceKaixiang(self-developed)
Data Processing SoftwareKaixiang(self-developed)


Manufacturing standards
 
Kaixiang Enterprise standards
 ( Initiatives in loadbank industry in China)
Q/01KX001-2010Dry-type AC load bank
National standards
GB/T 2820.5-2009Reciprocating internal combustion engine driven alternating current generating sets-part fifth: generator
GB/T 13032-2010Marine diesel generator
GB/T 1029-20053 phase synchronous moter test method
GB 14711-2006Safety requirements for rotating electrical motor
Enterprise standards
JB/T 10303-2001Generator technical condition
ISO
GB/T19001-2008Quality management system


Supply List
 
The following form presents the accessories provided when we make shipment.
 
 
ItemsQuantityRemark
AC380-1500kW Intelligent Load Bank1 sets 
Remote controller1Portable aluminium alloy box
Power Supply Cable13 meters
RS232130 meters
RS485/RS232/USB Converter1 
Documents accompanied with shipmentQuantityRemark
Products Instruction1 
Data Processing Software1 
Certification1 
Warranty Card112 months
Packing List1 
Receiving Apron1 
Testing Report1 

 
 
Send your message to this supplier
Avatar
Mr. Bruce
*From:
To: Mr. Bruce
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now