• 6.6kv 3MW Load Bank to Test Generator
  • 6.6kv 3MW Load Bank to Test Generator
  • 6.6kv 3MW Load Bank to Test Generator
  • 6.6kv 3MW Load Bank to Test Generator
  • 6.6kv 3MW Load Bank to Test Generator
  • 6.6kv 3MW Load Bank to Test Generator

6.6kv 3MW Load Bank to Test Generator

Conditions
of Use:
Trailer Type, Marine, Land Use
Usage: Standby Unit, Common Units
Output Type: AC Three Phase
Cooling
Method:
Air Cooled
Installation
Method:
Fixed
Generator
Type:
Diesel Generator
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC6.6-3000KW
Name
Load Bank
Voltage
6.6kv, 11kv
Power
3000kw
Frequency
50Hz,60Hz
Power Factor
1
Resistive
Metal Alloy
Step
500kw
Control
Local and Remote
Communication
RS485, RS232
Warranty
12 Months
Transport Package
Container
Specification
ISO
Trademark
Triumph Load
Origin
China
HS Code
90309300
Production Capacity
300units

Product Description

Generator set intelligent testing system

Generator set intelligent testing system can test output power and load capacity exactly. Its main function is to test electricity parameter contain dynamic parameter to all kinds of generating set. It is composed of monitor and load bank. It can achieve intellectualized and achieve special test to all kind of electricity parameter of generating set automatic and form schematics, curve and monitor report cooperating with position machine. It can completely give up handcraft operating. (Intelligent control, automatism and man can be selected).It can provide scientific test measure for high-power generating set equipment.
6.6kv 3MW Load Bank to Test Generator6.6kv 3MW Load Bank to Test Generator6.6kv 3MW Load Bank to Test Generator

Main feature and function

1.    It can test stable state three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency, run duration of generating set and so on.

2.    It has harmonic analysis function and power energy accumulation function. It can analyze voltage, 2-50 times harmonic capacity of current, total harmonic capacity.

3.    It has setting test, fluctuating test, transient test (load increase quick, load decrease quick) ,and can test automatic max voltage, min. voltage, max current, min. current, max frequency, min. frequency and restoring time.

4.    It is of powerful voltage oscillograph and photoelectricity isolate and RS485/RS232 com communication.

5.    Not only it can display all stable state parameter, but also the load increase quickly, load decrease quickly, voltage, current, frequency curve, voltage curve, current harmonic curve and harmonic content.

6.    Cooperating with software, It can achieve automatic testing all electricity parameter and form all kinds of chart, curve, and test report. The content of data is very abundant; the report form is of applicability. Data and report forms can be signed and changed format according to consumer's need.

7.    It is of four group load control functions. Its each group can control 25% load and combine four load forms of 25%, 50%, 75% and 100% or set oneself according to users' need.

8.    It is of load control function that can achieve the function of load increasing quickly and load decreasing quickly.

9.    It is of loading inductive or capacitive load.(It is designed specially according consumers' need)

10.   Control function not only can be controlled automatically by PC, but also manual operated with panel hand.

11.   It is configured three ways sensor interface of environment temperature, humidity and atmospheric pressure and can achieve automatically the measure of environment temperature, humidity and atmospheric pressure, display and upload(Consumer configures sensor by oneself).

12.   We adopt power input mode of optimize subsection for it that can be set convenient and covered all power. (1kw-Max 120kw, 0.5Kva -50.5kvA).

13.   It achieves intelligent control that can test automatic all kinds of parameter include dynamic parameters. It can provide scientific test measures for high-power generating set.

14.   Cooling measures: forced air cooling.

15.   Operation measure: load subsection control (single-pole double throw switch, controlled by contactor) can meet any power combination in rating power.

 

Rating voltage/frequency

6.6kV, 3 phase 50Hz

Max Load Power

 Resistive Load: 3000kW

Load Resolution

Resistive Load: 6steps, 500kW,500kW,500kW,500kW,500kW,500kW

Power Factor

1

Load Tolerance (each step)

±5%

Load Tolerance (overall)

±3%

Fan &Control Voltage

External AC 3 phase 4 line, 380V/50Hz

Wire Connection

Load bank input--Copper bar (star coupling "Y")

Control power input--Connector-bar

Communication Interface

RS485,RS232

Insulation

F

Max Protection Grade

IP54

Duty Cycle

Continuous  

Cooling

Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling

Enclosure

Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door

Internal Lighting

Adequate internal lighting will be provided

Transportation

Hoisting, there are lifting lug in top of casing

Color

Grey RAL7035 or as required

Dimensions

About 6058mm*2350mm*2591mm(L*W*H)

Operating Environment Parameter

Ambient Temperature

-10ºC~+50ºC

Relative Humidity

≤95%

Atmospheric Pressure

86~106kPa


6.6kv 3MW Load Bank to Test Generator
6.6kv 3MW Load Bank to Test Generator
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now