• 3 Phase Load Bank 1000kw Load Bank Unit for Generator Test Testing
  • 3 Phase Load Bank 1000kw Load Bank Unit for Generator Test Testing
  • 3 Phase Load Bank 1000kw Load Bank Unit for Generator Test Testing
  • 3 Phase Load Bank 1000kw Load Bank Unit for Generator Test Testing
  • 3 Phase Load Bank 1000kw Load Bank Unit for Generator Test Testing
  • 3 Phase Load Bank 1000kw Load Bank Unit for Generator Test Testing

3 Phase Load Bank 1000kw Load Bank Unit for Generator Test Testing

Conditions
of Use:
Land Use
Usage: Common Units
Output Type: AC Three Phase
Cooling
Method:
Air Cooled
Installation
Method:
Portable
Generator
Type:
Diesel Generator
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
3 phase load bank 1000kw
Voltage
AC 400V
Frequency
50Hz
Max Load Power
1000kw
Power Factor
1
Load Tolerance(Each Step)
±5%
Load Tolerance(Overall)
±3%
Display Precision
0.5 Class
Dimension
About 2440mm*1400mm*1680mm
Weight
About 1500kgs
Insulation Grade
F Class
Transport Package
Plywood Cases
Specification
1000kw load bank
Trademark
triumph load
Origin
Hebei, China
HS Code
9030339000
Production Capacity
10000set/Year

Product Description

3 Phase Load Bank 1000kw Load Bank Unit for generator test testing
Introduction

(1) According to the special requirements of users on site, in the agreement the technical standards of AC400-1000kW Automatic Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.
(2) The system consists of 1 sets of 1000kW Resistive load bank. The System is made up of two parts of measurement and control and load, mainly including AC dry load, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, PC software and so on.
3 Phase Load Bank 1000kw Load Bank Unit for Generator Test Testing3 Phase Load Bank 1000kw Load Bank Unit for Generator Test Testing
(3)This system, which is of independent research and development of electricity load test equipment by our technology, combining dry load module with the automatic measurement and control module, can accurately detect all kinds of generator output power and load capacity, full load and overload test.
The system can be used with a computer to realize the intelligent control, automatically completing the special test to all electrical parameters of generating set and generating tables, graphs, and supporting the print, comprehensively from the cumbersome manual operation to provide scientific and efficient detection means for the power generating sets.
(4) All the schematic diagrams of this agreement are for reference only please in kind prevail 
AC400-1000kW Automatic Load Bank
Rating Voltage/Frequency 400VAC, 3 phase 4 wire, wire voltage 400V, phase voltage 230V
50Hz
Rated Load Power Resistive load: 1000kW
Installed Capacity Resistive load: 1000kW
Load Step 1,2,2,5,10,10,20,50,100,200,200,200,200kW, min step load: 1kW
PF(Power Factor) 1
Load Tolerance  (each step) ±5%
Load Tolerance(overall) ±3%
Display Precision 0.5 class
Control Power External 380VAC/50Hz, 3 phase 4 wire, 220V 1-phase
Wire Connection Load power supply input--Copper bar 
Control power supply input--Connector-bar
Insulation F
Duty Cycle Continuous  
Cooling Type Force air cooling, horizontal air inlet and horizontal air outlet
Transportation Hoisting, there are lifting lug on top and castors at the bottom of casing
Dimension  About 2440mm*1400mm*1680mm(L×W×H)
Weight About 1500kgs
Casing Color Grey(RAL7035)or as required
Operating Environment Parameter
Workplace Indoor or outdoor  
Ambient Temperature -20ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤2500 meter
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Schneider
Fuse Miro
PLC Siemens
Data processing software Kaixiang(self-developed)
Alloy Resistance Kaixiang(self-developed)

3 Phase Load Bank 1000kw Load Bank Unit for Generator Test Testing

3 Phase Load Bank 1000kw Load Bank Unit for Generator Test Testing

4.Why choosing us
The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
The most patent technology and scientific research awards gainer in China.
Advanced detection method and strict inspection procedure build the qualified quality.
Customized production meet the individual requirement.
Prompt delivery & excellent after sales service.
Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.