• 400kVA Rlc Load Bank
  • 400kVA Rlc Load Bank
  • 400kVA Rlc Load Bank
  • 400kVA Rlc Load Bank
  • 400kVA Rlc Load Bank
  • 400kVA Rlc Load Bank

400kVA Rlc Load Bank

Voltage: 400V,415V,440V,480V
Power: 400kVA
PF: 0.8
Frequency: 50Hz
Min Step: 1kw,1kvar
Control: Local and Remote
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC400-400KVA
Communication
RS485,RS232
Warranty
12 Months
Transport Package
Container
Specification
ISO
Trademark
Triumph Load
Origin
China
HS Code
90303900
Production Capacity
300 Units/Year

Product Description

1. Product Introduction

RLC Loadbank, Containerised RLC Load Bank for Outdoor Introduction

The system is a self-developed device used for electricity load testing by Kaixiang Technology. 

It perfectly combines the dry type load module and measurement and control module, precisely test output power and load performance of kinds of generator set, and realize setting, fluctuation, instant load, instant unload, record wave analysis, 

and harmonic wave analysis, so to finish all the static parameters and dynamic parameters testing.

400kVA Rlc Load Bank400kVA Rlc Load Bank

Measuring Feature

Steady-state Test: load power in rated range, measure generator steady-state 3 phase voltage, current, active power, 

reactive power, apparent power, power factor, frequency, and running time. 

Setting Test: can catch the max and min setting value of voltage and frequency, and calculate the relative setting up and 

down range of voltage and frequency and adjustment rate within 100 seconds setting time.

Fluctuation Test: catch the max and min fluctuating value of voltage and frequency, and calculate steady-state frequency 

band, steady-state voltage deviation, voltage modulation, fluctuation rate and frequency in 60 seconds fluctuation time.

Transient Test (Instant Load Test): sample interval is 40μs,system catch the transient max and min value and 

recovery time of voltage, current, and frequency, and calculate instant load transient voltage deviation and instant load 

transient frequency deviation.

Transient Test (Instant Unload Test): sample interval is 40μs,system catch the transient max and min value and 

recovery time of voltage, current and frequency,  and calculate instant unload transient voltage deviation and instant 

unload transient frequency deviation.

Harmonic Analysis: It can analysis 2~50 harmonic content and total harmonic content in voltage and current at same 

time.

Record Wave Analysis: 5 patterns for recording voltage real-time waveform, and the record time is 4~ 280 seconds 

and accurately sampling at 128 points in a wave cycle at most.