1000kw 3 Phase Load Bank for Genset Test

Rating Voltage: 400VAC, 3 Phase 4 Wire, 50 Hz
Max Load Power: 1000kw
Load Accuracy (Each Step): ±5%
Load Accuracy (Overall): 3%
Display Precision: 0.5 Grade
Cooling: Fan Forced Cooling
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC400-1000kW
Dimensions
2300*1250*1680mm
Temperature
-10degree~+50degree
Casing Color
Grey(Ral7035)
Transport Package
Inner: Plastic Film, Outside: Wooden Case
Specification
ISO9001: 2008
Trademark
Triumph Load
Origin
Shijiazhuang, Hebei
HS Code
9030390000
Production Capacity
250sets/Year

Product Description

 Measuring Control Function of 1000KW 3 Phase Load Bank For Genset Test

1.Load testing:load power that not beyond the rated power, testing and display stable state 3 phases voltage, current, active power, reactive power, apparent power, power factor, frequency, working time, etc of generator sets.

2.Load/unload with one key: Whether manual control and software control, user can preset the power, then press load master button. Load bank load according to preset power to avoid load fluctuation during the power changing.

3.Control Pattern: user can choose local control and intelligent control.

4.Local Control: There is local control panel with several power steps, user can load/unload by button.

5.Intelligent Control(automatic control ): Through data processing software in PC, user can make automatic load, to display, record and manage the testing data, to form curves, tables, also to print them.

6.Control Pattern interlock: there is control pattern switch, when choose one control pattern, operation of other pattern is invalid, avoid the clash.

7.Local meter display data: local meter can display 3 phases voltage, current, active power, reactive power, apparent power, frequency and so on.

 

1000KW 3 Phase Load Bank For Genset Test

AC400-1000kW

Rated voltage /Frequency

AC 3phase 4wire 400V/50Hz

Max load power

Resistor load: 1000kW

Load step

Resistive load: 13 steps, 1,2,2,5,10,10,20,50,100,200,200,200,200kW

Power factor

1

Load Tolerance(each step)

±5%

Load Tolerance(overall)

±3%

Display Precision

0.5 class

Control Power Supply

External AC380V/50Hz Three phase four wire

Wire Connection

Load power supply input--Copper bar (star coupling)

Control power supply input--Connector bar

Insulation grade

F class

Max protection class

IP21

Duty cycle

Continuous

Cooling

Forced air cooling, Horizontal inlet air, Upward cooling

Casing structure

Container packaging, equip with ladder up to the top, inlet and outlet of air equip with mesh enclosure and protective door

Transportation

Hoisting, there are lifting lug in top of casing

Casing Color

Grey(RAL7035)

Dimension

 

Weight

 

Operating Environment Parameter

Ambient Temperature

-10ºC~+50ºC

Relative Humidity

≤95%

Altitude

≤2500 meters

Atmospheric Pressure

86~106kPa

Main components brand

Contactor

Schneider

Fuse

Miro

PLC

Siemens

Alloy resistor

Kaixiang

Data management software

Kaixiang

 Pictures of 1000KW 3 Phase Load Bank For Genset Test
1000kw 3 Phase Load Bank for Genset Test
1000kw 3 Phase Load Bank for Genset Test
1000kw 3 Phase Load Bank for Genset Test
1000kw 3 Phase Load Bank for Genset Test
1000kw 3 Phase Load Bank for Genset Test
1000kw 3 Phase Load Bank for Genset Test

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now