Load Banks 20kw for Generator UPS Inverter Testing

After-sales Service: 12 Months
Warranty: 1 Year
Brand: Triumph Load
Working Voltage: AC 3-Phase 4-Wire 380V/50Hz
Application: Lead-Acid Battery
Customized: Customized
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
Load Banks 20kw
Transport Package
Plywood Cases
Specification
AC 20kw
Trademark
triumph load
Origin
China
HS Code
9030339000
Production Capacity
10000set/Year

Product Description

Load Banks 20kw for generator UPS inverter testing
According to the special requirements, we work out a solution AC380-20kW Automatic Load Bank (we called system in following paragraphs), including technical standard of function, performance, instruction, structure, installation and testing.
System consists of measuring control and load bank. Mainly including Dry Type AC Load Bank, Data Acquisition System, Automatic Load/unload Control System, Cooling Device, Assist-control Device and PC software(English).
All the pictures in this solution are only for reference, according to the real object please.
We will introduce the system structure, principle, function and characteristics.
AC380-20kW Automatic Load Bank
Rating Voltage/Frequency 380VAC, 3 phase 4 wire, 50Hz, phase voltage 220V
Max Load Power Resistive load:20kW
Load Step 5 steps, Resistive load:1kW,2kW,2kW,5kW,10kW, min load step: 1 kW
Power Factor 1
Load Tolerance(each step) ±5%
Load Tolerance(overall) ±3%
Display Precision 0.5 class
Control Power Supply AC220V/50Hz single phase
Wire Connection Load power supply input--star coupling
Control power supply input--terminal block
Duty Cycle Continuous  
Communication Interface RS485,RS232
Cooling Forced air cooling, horizontal inlet air and horizontal outlet cooling
Transportation Hoisting, there are lifting lug on top of casing and casters at bottom of load bank
Casing Color Grey(RAL7035)
Operating Environment Parameter
Ambient Temperature -10ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤1500 meters
Atmospheric Pressure 86~106kPa
Brands of Main Components
Fuse Miro
PLC Siemens
Alloy Resistor Kaixiang(self-developed)
Data Processing Software Kaixiang(self-developed)
Load Banks 20kw for Generator UPS Inverter Testing





4.Why choosing us

The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
The most patent technology and scientific research awards gainer in China.
Advanced detection method and strict inspection procedure build the qualified quality.
Customized production meet the individual requirement.
Prompt delivery & excellent after sales service.
Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.
Load Banks 20kw for Generator UPS Inverter TestingLoad Banks 20kw for Generator UPS Inverter TestingLoad Banks 20kw for Generator UPS Inverter Testing
5.Contact Information


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now