Voltage: AC400V-13.8kv
Frequency: 50/60Hz
Max Load Power: 1250kw
Power Factor: 1
Load Tolerance(Each Step): ±5%
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
Resistive and inductive Load Bank 1250kw
Load Tolerance(Overall)
±3%
Display Precision
0.5 Class
Dimension
2400*1600*1800mm
Weight
About 1800kg
Insulation Grade
F Class
Transport Package
Container
Specification
1250kw
Trademark
triumph load
Origin
China
HS Code
9030339000
Production Capacity
1000set/Year

Product Description

Electrical Resistive and inductive Load Bank 1250kw for UPS Generator Transformer Testing
Regenerative Power Load Banks 
Introduction:
Resistance/inductance/capacity/Portable Intelligent load bank 
Intelligent AC load bank main used to test the capability and aging degree for high-power ups on-line, inverter, switch power and diesel generator set for electric power, telecom department and manufacturer. It can ensure the reliability of constant power charge that adopts uniformly stepped power input, energy consumption work model and forced air-cooling model. It is of high power density, no red hot phenomenon and automatic protection function overheated. It can't be overheated and broken when the fans stop working. The complete machine can be operated simply and maintain convenient that adopts module design. It can test voltage and current according to client's request, and provide scientific test measures for high-power AC equipment.
Main functions of  Regenerative Power Load Banks 
1. Users can set adjustable discharge power according to capability parameter and test request.
2. Voltage and current value can be displayed with multi-functional digital meter.
3. AC load bank is of all kinds of specifications and series, and include resistance, inductive and capacitive load.
4. Two or more Intelligent AC Load Bank can operate in parallel.
5. It can make stable state test. 
6. Remote control by software.
7. Testing data can be saved or transferred by RS485, data can form curve, to be printed. 
Function options of  Regenerative Power Load Banks 
Intelligent AC Load Bank has two control patterns: position machine software control and local panel control
Intelligent AC load bank (LED): multi-function digital special meter of 0.5 step can be test and display: AC voltage, current, active power, power factor and frequency. It can communicate with PC via RS485 interface.
Intelligent AC load bank (LCD): Special LCD meter display: AC voltage, current, active power, power factor and voltage frequency. It is of the harmonic analysis function of 1-40 times, and can communicate with PC via RS485 interface.
2.Electrical resistive and reactive Load Bank 1250kw for UPS Generator Transformer Testing
System Parameter
Rating voltage/frequency 400V, 3 phase 4 wire 60Hz
Max Load Power Apparent Power: 1250KVA
Resistive Load: 1000kW
Inductive Load: 750KVAR
Load Resolution Resistive Load: 13 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,200kW,200kW,200kW, 200kW 
Inductive Load: 13 steps 
1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 50KVAR, 100KVAR,100KVAR,200KVAR,200KVAR
Power Factor 0.8(lag)
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage according to customer request
Wire Connection Load bank input--Copper bar
Control power input--Connector-bar
Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP54
Duty Cycle Continuous  
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions 2400mmx1600mmx1800mm(L×W×H)
Operating Environment Parameter
Workplace  Indoor or outdoor
Ambient Temperature -20ºC~+50ºC
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa


Electrical Resistive and Inductive Load Bank 1250kw for UPS Generator Transformer Testing

Electrical Resistive and Inductive Load Bank 1250kw for UPS Generator Transformer TestingElectrical Resistive and Inductive Load Bank 1250kw for UPS Generator Transformer Testing

4.Why choosing us

The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
The most patent technology and scientific research awards gainer in China.
Advanced detection method and strict inspection procedure build the qualified quality.
Customized production meet the individual requirement.
Prompt delivery & excellent after sales service.
Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.
5.Series Products:
Automatic AC load banks      Intelligent AC load banks      High-power load banks
Genset intelligent testing systems      AC/DC load banks
Intelligent battery discharger            UPS intelligent high-voltage discharger
Single cell test & discharge series     DC automatic load banks
Intelligent charge/discharge tester     Intelligent battery integrated tester
Intelligent battery activation series    Fully automatic charger
Intelligent charger series                  Intelligent charge & monitor
On-line battery parameters monitor
load bank battery load bank resistive load bank load bank resistor dc load bank dummy load bank 
load bank for generator testing load bank for sale battery test load bank electronic load bank 
battery test dummy load bank variable resistive load bank ac load bank generator load bank electrical load bank 
1000kw load bank 3 phase load bank adjustable resistive load bank inductive load bank portable load bank 
resistor load bank ac variable load bank 100kw load bank 200kw load bank 110v dc load bank 
500kw dummy load bank  generator load bank for sale  50kw load bank 500kw load bank 10kw load bank 
single phase load bank 48vdc load bank  5kw load bank 20kw resistive load bank rlc load bank  
48v 100a dc load bank 100kw resistor load bank dc load bank price ac 10kw load bank 100kva load bank 
resistive reactive load bank  10kw dc load bank load bank 200kw load bank heating coil load bank 500kw 
load bank 100kw 30kw load bank dummy load bank for generator 11kv 2mw load bank 30kw resistive load bank 
50kw resistive load bank dc load bank 48v 3 kw load bank single phase load bank 48vdc load bank 
5kw load bank 20kw resistive load bank rlc load bank  48v 100a dc load bank 100kw resistor load bank 
dc load bank price ac 10kw load bank 100kva load bank resistive reactive load bank 10kw dc load bank 
load bank 200kw load bank heating coil load bank 500kw load bank 100kw 30kw load bank  
dummy load bank for generator 11kv 2mw load bank 30kw resistive load bank  50kw resistive load bank  
dc load bank 48v 3 kw load bank power testing load bank  load bank  battery load bank  30kva load bank  
kaixiang load bank  battery load tester  used load banks  3 phase load bank  high quality load bank  
battery charger  1000kw load bank  500kw dummy load bank  battery discharger  dummy load  
variable resistive load bank  battery tester  air max 270  resistive load bank 5kw  load banks  load bank for sale  
Regenerative Power Load Banks 
Electrical Resistive and Inductive Load Bank 1250kw for UPS Generator Transformer Testing


Electrical Resistive and Inductive Load Bank 1250kw for UPS Generator Transformer Testing



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now