Customization: | Available |
---|---|
After-sales Service: | 12 Months |
Rated Power: | 150kw |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Resistance/inductance/capacity/Portable Intelligent load bank
Intelligent AC load bank main used to test the capability and aging degree for high-power ups on-line, inverter, switch power and diesel generator set for electric power, telecom department and manufacturer. It can ensure the reliability of constant power charge that adopts uniformly stepped power input, energy consumption work model and forced air-cooling model. It is of high power density, no red hot phenomenon and automatic protection function overheated. It can't be overheated and broken when the fans stop working. The complete machine can be operated simply and maintain convenient that adopts module design. It can test voltage and current according to client's request, and provide scientific test measures for high-power AC equipment.
Main functions
1. Users can set adjustable discharge power according to capability parameter and test request.
2. Voltage and current value can be displayed with multi-functional digital meter.
3. AC load bank is of all kinds of specifications and series, and include resistance, inductive and capacitive load.
4. Two or more Intelligent AC Load Bank can operate in parallel.
5. It can make stable state test.
6. Remote control by software.
7. Testing data can be saved or transferred by RS485, data can form curve, to be printed.
Function options
Intelligent AC Load Bank has two control patterns: position machine software control and local panel control
Intelligent AC load bank (LED): multi-function digital special meter of 0.5 step can be test and display: AC voltage, current, active power, power factor and frequency. It can communicate with PC via RS485 interface.
Intelligent AC load bank (LCD): Special LCD meter display: AC voltage, current, active power, power factor and voltage frequency. It is of the harmonic analysis function of 1-40 times, and can communicate with PC via RS485 interface.
Technical Parameters |
||
Rating Voltage/Frequency |
AC 400V/50Hz, 3 phase 4 wire |
|
Max Load Power |
Resistive Load: 150kW |
|
Load Steps |
Resistive Load: 6 steps, 25kW,50kW, 75kW,100kW,125kW,150kW |
|
Power Factor |
1 |
|
Load Tolerance(each step) |
±5% |
|
Load Tolerance(overall) |
±3% |
|
Display Precision |
Class 0.5 |
|
Control Power Supply |
Internal AC 3phase 400V/50Hz |
|
Wire Connection |
Load Power Input --(star type connectionL1(red),L2(white),L3(blue)) |
|
Wiring Requirement |
Power cable red color, L1: red L2: white L3: blue Control cable black color,L1: red L2: white L3: blue N: black PE:yellow green
|
|
Insulation Grade |
Class F |
|
Duty Cycle |
Continuous |
|
Cooling Type |
Forced air cooling, air inlet from bottom, air outlet from top |
|
Transportation |
Hoisting, there are lifting lugs in top of case and wheel castors on the bottom |
|
Enclosure Color |
Sky blue RAL 5015 |
|
Enclosure Dimension |
About 1200mm*1000mm*1300mm(L×W×H) |
|
Weight |
About 260kgs |
|
Operating Environment Parameter |
||
Ambient Temperature |
-10ºC~+40ºC |
|
Relative Humidity |
≤95% |
|
Altitude |
≤2500 meters |
|
Atmospheric Pressure |
86~106kPa |