• 2.5MW Load Bank for Generator Testing
  • 2.5MW Load Bank for Generator Testing
  • 2.5MW Load Bank for Generator Testing
  • 2.5MW Load Bank for Generator Testing
  • 2.5MW Load Bank for Generator Testing
  • 2.5MW Load Bank for Generator Testing

2.5MW Load Bank for Generator Testing

Rated Power: 2500kw
Rated Voltage: 380V/400V/415/440/480V
Power Factor: 1
Duty Cycle: Continuous
Cooling: Industrial Heavy Duty Blower, Horizon Air Intake,
Control Mode: Manual/Remote/Software
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
3 phase load bank
Dimension
6058mm*2438mm*2591mm
Resistance
Special Alloy Resistance
Casing Material
Corrosion Resistant Aluminum Alloy
Monitoring & Display Meter
Voltage, Current, Power, Power Factor, Frequency
Transport Package
Wooden Case
Specification
ISO9001: 2008
Trademark
Triumph Load
Origin
Shijiazhaung, Hebei, China
HS Code
9030390000
Production Capacity
15 Sets/Month

Product Description


Compact and Lightweight design that is ideal for moving from job site to job site or within your facility.
It offers the most robust, high-capacity designs in the industry.  It is setting the standard with intelligent operator controls, safety indication layouts, adjustable load step resolution, and lightweight designs.  It is the perfect solution for regularly scheduled maintenance testing and commissioning of mission-critical standby emergency power systems.
 
Main features
1. Multiple control mode: (1) manual panel control (2) remote control (3)software control
2. Multiple display function: voltage, current, frequency, power factor, active power, reactive power, apparent power etc.  
2. Multiple protection function: overvoltage, overcurrent, overheat, over low blowing rate, blower overheat, blower phase sequence reverse protection, smoke alarm etc.
3. Forced air cooling: industrial heavy duty fan, horizon air intake, upwards outlet, low noise.
4. Power consumption components: made by special alloy resistance, high temperature resisting, high heat dissipation capability, high heat stability, no naked light, safety and reliability. Running temperature is 1/3 of rating.
5. Weather-proof structure: containerized structure provides ultra protection, protection grade higher than IP55.
6. Material and coating: the body adopt cold-rolled steel plate that processed by galvanizing corrosion protection, powder coated and spray paint.
7. Integrated & modularization design: compact structure, easy to installation, maintenance and transportation.
8. Software control: it can test and display voltage, current, frequency, power factor, active power, reactive power, apparent power etc, the test result can be store & print and form all kinds of curve, chart and test report.
 
Resistive Load bank
Introduction
Resistive load bank is a device which can simulate the real-life resistive loads and provides a rigorous test regime for power supplies from 1kW to 60MW.The "load" of a resistive load bank is created by the conversion of electrical energy to heat by power resistors. It mainly used to test and maintenance of Engine Generators, Storage Battery Systems, UPS Systems, Inverters, Ground Power Units, Auxiliary Power Units, Aircraft Power Generators, Wind Generators, Hydro Generators etc.
Resistive load bank are available in stationary type for permanent installation or portable type with lifting rings, castors. Larger load banks, typically above 1250KW, are based on an ISO container construction. Special finishes including custom paint colors and stainless steel casings can be supplied.
 
Resistive /Reactive Load Bank
Introduction
The RL Series Resistive Reactive Load Bank can simulate motor loads and electromagnetic devices within a power system as well as purely resistive loads by offering the ability to set a specific power factor (pf). Resistive Reactive Load Bank is the perfect solution for regularly scheduled maintenance testing and commissioning of mission-critical standby emergency power systems where rated kVA, rated power factor and rated current testing is required. Usually, it offers a 0.80 power factor load and is designed for testing large generators, switchgear, transformers and UPS systems.
Resistive Reactive Load Bank can be designed to install the resistive components and reactive components in one enclosure or two separate enclosure. Same as the Resistive Load Bank, it is available in stationary type for permanent installation or portable type with lifting rings, castors. Larger load banks, typically above 1250KVA, are based on an ISO container construction. Special finishes including custom paint colors and stainless steel casings can be supplied.
Technical Parameters

Model

Installed Capacity

Power Factor

Load Voltage

Dimension
W*D*H(mm)

Weight(kg)

AC400-20k

21kw

1

3 phase 400V 50HZ/60HZ

480*485*680

30

AC400-100k

110kw

700*900*900

80

AC400-200k

210kw

1200*1500*1500

200

AC400-500k

510kw

1460*1980*1800

750

AC400-1000k

1010kw

1600*2400*2100

1500

AC400-2000k

2010kw

6058*2438*2591

5000

AC400-3000k

3010kw

7000

AC400-4400k

4410kw

8000

The parameters is only for reference, pls contact supplier for exact information
High Voltage Load Bank
Introduction
The ability to test critical power systems at voltages of 1.2KV to 80kV using direct-connect, High Voltage Load Bank offers engineers flexibility, time savings, cost savings, space savings and simplicity. It mainly used to commission utility, oil & gas, and industrial power systems without the need for additional transformers and cabling.
Technical Parameters

Model

Installed Capacity

Power Factor

Load Voltage

Dimension
W*D*H(mm)

Weight(kg)

AC10.5KV-2000K

2000KW

1

3 phase 10.5KV 50HZ/60HZ

6058*2438*2591

6000

AC10.5KV-3000K

3050KW

9150*2438*2591

8000

AC10.5KV-5000K

5050KW

12100*2438*2591

10000

The parameters is only for reference, pls contact supplier for exact information
 
The Main Application Of The Load Bank
 
Factory testing of engines generator sets
To reduce "wet stacking" problems
Periodic exercising of stand-by engine generator sets
Load testing of AC power source
On-site acceptance testing
UPS system testing and maintenance
New projects inspection and battery system maintenance
Load optimization in prime power applications
 
Main 10 Technology Advantages
Kaixiang company is in leading position in generator set testing and maintenance industry, besides general functions, its load bank has following unique advantages:
1. Standard Testing Function: The load bank can do stable test, transient test, and realize functions, such as setting, fluctuation, instant load, and instant unload.
2. Super Power Load: high load power density, large capacity of single set, parallel running to finish super power testing, and realize tens of megawatts of power loading.
3. Accurate Data: with high precision data collection module and measuring meter, related equipment has passed the certification by CMA (China Metrology Accreditation) qualification testing institution, and ensure the reliability of data.
4. Flexible Control Mode: based on different using habit, several control mode as following can be choosed, local panel operation, remote box controlling, and intelligent software. 
5. Intelligent Load: after setting generator rated power in software, system realize rapid loading through preset proportion, automatically and continuously load multiple power value and common tests, like stepping, full load, and over load, so that improve working efficiency.
6. High Efficiency Data Management: display real-time testing data, generate form, curve graph or report automatically, also can put data into storage. According to generator set No. set up testing file, support to query at any time, and improve data management efficiency.
7. Comprehensive Protection Function: multiple protection, like over temperature, smoke. When in danger, automatically terminate the test and give alarm to protect safety of personnel and equipment.
8. Stable Running: with the latest generation control module as the core, a sharp rise in system response speed and anti-interference performance, avoid function failure in complex electrical environment, and ensure system running stably and reliably. 
9. New Load Bank Technology: using the international advanced AC load bank technology, overcome the old water bank defects, such as bear bumpy, unable to use when go to sea, realize Mooring Trial and Sea Trail, and simulate the real working condition of generator running.  
10. Mature Manufacturing Technology: load element using excellent anti-corrosion materials, waterproof insulation container packaging, suitable for adverse environment such as ocean. Internal layout is reasonable, air channel is clear, rapid heat emission, and satisfy continuous working need.
What We Can Do
1. Professional technical team with more than 20 years design experience.
2. Customized technical solutions meet customer's individual requirements.
3. Skilled workman insure the reliable assembly technology.
4. Strict inspection procedures throughout the whole production flow.
5. Prompt delivery & custom clearance make sure the customers receive the goods on time.
6. Perfect after sales service create good user experience.
7. Reliable quality & competitive price help customers to maximize profits.
8. Timely feedback save valued time for the customer.
9. Humanized management system build homelike work atmosphere.
10. Continuous devote to public welfare undertakings strive for harmonious society.
2.5MW Load Bank for Generator Testing
2.5MW Load Bank for Generator Testing2.5MW Load Bank for Generator Testing2.5MW Load Bank for Generator Testing2.5MW Load Bank for Generator Testing2.5MW Load Bank for Generator Testing

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now