Customization: | Available |
---|---|
Conditions of Use: |
Land Use |
Usage: | Common Units |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Load bank for generator power banks testing system
1. Product Introduction
AC380V-50KW Generator power banks testing system
It is designed for AC power maintenance,could be used widely in communication base,power supply,power station etc.This machine is small,light weight digital table display,easy operation,high intelligence, set the parameters of constant current discharge process can be done automatically.
2. AC380V-50KW Generator power banks testing system
Large generator system testing in ocean engineering, drilling facilities,ship construction etc field;
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection
test;
Assist shipyard in mooring test,sea trial test;
Assist with the acceptance of the vessel generator test;
Eliminate the carbon deposition of generator;
As the generator loading system;
Periodic running test for standby generator;
UPS inspection and maintenance;
Ship battery charging/discharging system testing;
The acceptance of new system and testing of servicing equipment.
3. AC380V-50KW Generator power banks testing system
Altitute:≤1500m
Temperature:-10°C~50°C
Humidity:≤95%RH
Working Mode:Continuous work(>6hours continuous long-term work per day)
4. AC380V-50KW Generator power banks testing system
Technical parameter |
|
AC380V-50KW |
|
Rated voltage /Frequency |
AC 380V/50Hz,3 Phase 4 Wire |
Max load power |
Resistive load: 50KW |
Load step |
1 2 2 5 10 10 20 |
Power factor |
1 |
Load Tolerance(each step) |
±5% |
Load Tolerance(overall) |
±3% |
Display Precision |
0.5 class |
Control Power Supply |
according to customer request |
Wire Connection |
Load power supply input--connector bar(star coupling) Control power supply input--Aviation plug |
Insulation grade |
F class |
Duty cycle |
Continuous |
Cooling |
Forced air cooling, Horizontal inlet air and outlet air |
Transportation |
Hoisting, there are lifting lug in top of casing and casters in bottom of load bank |
Casing Color |
Grey(RAL7035) |
Dimension |
About 1000mm*1000mm*2000mm(length*width*height) |
Weight |
About 80kg |
Operating Environment Parameter |
|
Ambient Temperature |
-20ºC~+50ºC |
Relative Humidity |
≤95% |
Altitude |
≤2500 meters |
Atmospheric Pressure |
86~106kPa |
Main components brand |
|
Circuit Breaker |
Siemens |
Fuse |
Delixi |
SCM |
Infineon |
Alloy Resistor |
Kaixiang |
Data Management Software |
Kaixiang |
5.AC380V-50KW Generator power banks testing system