Liquid Cooling Load Bank 30kw Resistive Load Bank for Data Center Testing

Product Details
Customization: Available
After-sales Service: Forever
Warranty: 12months
Still deciding? Get samples of US$ 3500/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Liquid Cooling Load Bank 30kw Resistive Load Bank for Data Center Testing
  • Liquid Cooling Load Bank 30kw Resistive Load Bank for Data Center Testing
  • Liquid Cooling Load Bank 30kw Resistive Load Bank for Data Center Testing
  • Liquid Cooling Load Bank 30kw Resistive Load Bank for Data Center Testing
  • Liquid Cooling Load Bank 30kw Resistive Load Bank for Data Center Testing
  • Liquid Cooling Load Bank 30kw Resistive Load Bank for Data Center Testing
Find Similar Products

Basic Info.

Model NO.
30kw load bank
Max Diameter of Workpiece
500mm
Mass Scope of Workpiece
<900kg
Type
Testing Electrical Equipment
Maxcapacity
>1000KN
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Computer Control
Weight
1000-2000Kg
Power Source
AC220V
Oil Cylinder Position
No
Color
Variety
Dimension
6 U , 430mm*266mm*620mm
Load Tolerance
5%
Transport Package
Plywood Cases
Specification
30kw
Trademark
triumph load
Origin
China
HS Code
90303390
Production Capacity
100/Month

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
10.000kg

Product Description

Liquid Cooling Load Bank 30kw resistive Load Bank for data center testing
Product introduction

Liquid-cooled loads can be used to simulate the actual heat generation and power consumption of real servers in the server room, to test the effect of liquid cooling in the server room and the safety of power consumption in the server room lines, and to provide a data basis and test means for the availability of the server room system.
Liquid-cooled load adopts modularized design scheme, which is easy to maintain and replace, and can be used as a single unit or multiple units in parallel, with multiple gears adjusted for each unit.


Specification
Technical Parameters
Rated voltage AC three-phase, phase voltage 220V/50Hz or DC 240~270V
Rated power 30KW (10kW per Section @ AC 220V/50Hz)
Load Steps A single module has 3 independent input ports, each with 10kW.
Load Steps (AC220V/50Hz):
Section A: 1kW, 2kW, 3kW, 4kW;
Section B: 1kW, 2kW, 3kW, 4kW;
Phase C: 1kW, 2kW, 3kW, 4kW;
Note:
1. The three sections of ABC are controlled independently, and each section is divided into different steps. It can be used in either single-phase or three-phase.
2. The heating material is alloy resistor. When DC is 240~270V, the gear power changes according to Ohm's law based on AC220V .
Power Factor 1
Heat Exchange Efficiency ≥95%
Full Load Tolerance ≤±5%
Main Circuit power Interface C14 interface, 5 per section, with protective cover.
Load Mode The panel is equipped with a load switch (small circuit breaker) and manual loading
Control Power Power supply by the power interface under test
Insulation Level AC1000V, Insulation Resistance ≥10MΩ
Inlet Water Temperature 5-80ºC
Water Circuit Interface 1 water inlet pipe and 1 return water pipe, clamp type quick connector, pipe diameter: DN25.
Water outlet with exhaust/water valve (manual). The return pipe is equipped with a flow regulating valve and a filter. The filter is installed at the return pipe outside the module.
Pressure The liquid cooling container or resistor can withstand 1.0MPa working pressure, and the ultimate experimental pressure is 1.5 times the working pressure.
Air Tightness No leakage for 2 hours under 1Mpa pressure
Water Flow 1-10m3/h
Cooling Mode High grade pure water cooling
Insulation level Class F
Protection Grade IP23
Working Mode Continuously working
Pipe Material All pipes are made of stainless steel 304. The containers and pipes are pickled and passivated before delivery to ensure the cleanliness of the water during testing.
Panel Instruction and
Parameter Display
The load panel has a power working indicator light and a fault alarm indicator light.
The inlet and outlet water temperature sensors display temperature, current, voltage, and power data (the display screen has a protective cover), and the sensor accuracy is 0.5.
Parameter Expansion Display
(Extensions)
The equipment reserves 4 sets of 4~20mA signal acquisition modules and input signal access positions, and provides a 24V power supply interface. Users can expand the collection function by adding corresponding collection sensors (such as inlet and outlet water pressure sensors, flow sensors, etc.) Extended acquisition function, the local touch screen design reserves the display and storage functions of the corresponding blocks for users to expand functions.
Installation Process The pipelines adopt reliable connection methods such as flanges and clamps, and the seals meet the requirements of durability and non-pollution of cooling water. The internal pipeline part is insulated and protected. The external interface of the load is equipped with a stainless steel blind plate. When the equipment is idle, the interior can be filled with nitrogen for protection, meeting dust proof and anti-corrosion requirements.
Welding Process All use argon arc welding bottom welding process.
Over Temperature Protection The load brings in and out water temperature monitoring, and alarm prompts when the water temperature is abnormal (inlet and outlet water temperature upper and lower limit alarms, adjustable values, two-stage alarm, one-stage alarm prompt, two-stage alarm for unloading).
Over Current Protection When switching over-current protection, the audible and visual alarm prompts and cuts off the over-current load;
Pressure protection (extended function) The load can monitor the inlet and outlet water pressure. When the pressure exceeds the set value (the alarm value can be set), an alarm will be given and the load will be cut off.
Ground Protection The load input port has a ground wire connected to the chassis, and the chassis body has a ground terminal for user grounding.
Protection and Interlock When one or more AC and DC circuit breakers are over current, in addition to the audible and visual alarm, the load of the over current circuit breaker must be cut off at the same time. It must be manually confirmed to be powered off and reset before it can continue to be used.
It is required that the load cannot be loaded when the coolant is not detected; when the temperature is too high, in addition to the audible and visual alarm, the load must be cut off at the same time, and the power-off reset must be manually confirmed before continued use.
Cabinet Dimension 6 U , 430mm*266mm*620mm (W*H*D), excluding the size of the caster.
Cabinet Color As per your request
Weight ≤35kg
Transportation There are lifting handles on the side and casters at the bottom for easy transportation;
Load Cable The internal cables are made of multi-core flame-retardant soft wires, protected by fiberglass casings and have waterproof and anti-corrosion capabilities.
Liquid Cooling Load Bank 30kw Resistive Load Bank for Data Center TestingLiquid Cooling Load Bank 30kw Resistive Load Bank for Data Center TestingLiquid Cooling Load Bank 30kw Resistive Load Bank for Data Center TestingLiquid Cooling Load Bank 30kw Resistive Load Bank for Data Center TestingLiquid Cooling Load Bank 30kw Resistive Load Bank for Data Center TestingLiquid Cooling Load Bank 30kw Resistive Load Bank for Data Center Testing
Why Choosing Us?

1. Hebei Kaixiang Electrical Technology Co., Ltd is the largest and earliest load bank manufacturer in China, we have 20 years experience. Our factory has 25,000 square meters. We are the leader in domestic market.
2. The sole company that draft the enterprise standard "dry-type load bank".
3. China Power Industry Top Ten Famous Products.
4.  China Power Supply Recommend Products.
5.  Our Intelligent High Power Marine Use Gensets Dry Type Load Bank wins International advanced level by Science and Technology Department of Hebei Province.
6. Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
7.  Certified by SGS.
certificate
Liquid Cooling Load Bank 30kw Resistive Load Bank for Data Center TestingLiquid Cooling Load Bank 30kw Resistive Load Bank for Data Center Testing



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier