• Dual Voltage Load Bank for Generator Testing
  • Dual Voltage Load Bank for Generator Testing
  • Dual Voltage Load Bank for Generator Testing
  • Dual Voltage Load Bank for Generator Testing
  • Dual Voltage Load Bank for Generator Testing
  • Dual Voltage Load Bank for Generator Testing

Dual Voltage Load Bank for Generator Testing

Voltage: AC 3-Phase 4-Wire 400V
Frequency: 50Hz
Rated Capacity: 208kVA
Resistive Power: 69.33kw
Inductive Power: 69.33kvar
Capactive Power: 69.33kvar
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC380/660-2500kVA
Load Tolerance
±5%
Control Power Supply
External AC220V/50Hz Single Phase
Cooling
Forced Air Cooling, Horizontal Inlet Air, Upward C
IP Grade
IP21
Transport Package
Wooden Case
Specification
6 Cubic Meter
Trademark
Triumph Load
Origin
Hebei, China

Product Description

Dual Voltage Generator Dummy Load Bank
1.Product Introduction
2500KVA Generator Dummy Load Bank
Engine Dummy Load Bank for Generator Testing is composed of outdoor resistor-inductance AC load bank,data 
collection system,electric control module,thermal module,control part etc.It can accurately detect Marine generator output power and load capacity,and assist shipyard in acceptance of vessel,mooring test,sea trial,load test,static voltage 
characteristic test, speed characteristic test,overload protection test,reverse power and reverse current protection test,and 
parallel operation test etc.

Dual Voltage Load Bank for Generator TestingDual Voltage Load Bank for Generator TestingDual Voltage Load Bank for Generator Testing
 
2.2500KVA Generator Dummy Load Bank Application
Large generator system testing in ocean engineering, drilling facilities,ship construction etc field;
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test;
Assist shipyard in mooring test,sea trial test;
Assist with the acceptance of the vessel generator test;
Eliminate the carbon deposition of generator;
As the generator loading system;
Periodic running test for standby generator;
UPS inspection and maintenance;
Ship battery charging/discharging system testing;
The acceptance of new system and testing of servicing equipment.

Dual Voltage Load Bank for Generator TestingDual Voltage Load Bank for Generator Testing
 
3.200KVA Generator Dummy Load Bank Working Environment
Altitute:≤2500m
Temperature:-10°C~50°C
Humidity:≤95%RH
Working Mode:Continuous work(>6hours continuous long-term work per day)
 
4.2500KVA Generator Dummy Load Bank Technical Specifications

Technical parameter

AC400-2500KVA-RL

Rated voltage /Frequency

3-phase 4-wire 400V, 50Hz;1-phase 220V, 50Hz

Apprent Power

2500KVA

Load Distribution

Resistive power:69.33KW, Inductive power:69.33Kvar, Capacitive power:69.33Kvar

 Resistor divider file

(1-10)W, (10-100)W, (100-1000)W, 1, 2, 2, 2, 5, 10KW, stepping value 1W, each phase 23.11KW,in total 69KW

Reactance file

(1-10)var, (10-100)var, (100-1000)var, 1, 2, 2, 2, 5, 10Kvar, stepping value 1var, each phase 23.11KW,in total 69Kvar

Cpacitance file

(1-10)var, (10-100)var, (100-1000)var, 1, 2, 2, 2, 5, 10Kvar, stepping value 1var, each phase 23.11KW,in total 69Kvar

Power factor

0.8(0.2-1)

Load Tolerance(each step)

±5%

Load Tolerance(overall)

±3%

Display Precision

0.5 class

Control Power Supply

External AC single phase connection 220V/50Hz 

Wire Connection

Load power supply input--Copper bar (star coupling)
Control power supply input--Connector-bar

Insulation Grade

F class

Protection Grade

IP21

Duty Cycle

Continuous

Cooling

Forced air cooling, Horizontal inlet air, Vertical cooling 

Transportation

Hoisting, there are lifting lug in top of casing and casters in bottom of load bank

Casing Color

Grey(RAL7035)

Operating Environment Parameter

Ambient Temperature

-10ºC~+50ºC

Relative Humidity

≤95%

Altitude

≤1000 meters

Atmospheric Pressure

86~106kPa

Main components brand

Contactor

Schneider

Circuit Breaker

Siemens

Fuse

Delixi

SCM

Infineon

Alloy Resistor

Kaixiang

Data Management Software

Kaixiang

4.Why choosing us
The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
The most patent technology and scientific research awards gainer in China.
Advanced detection method and strict inspection procedure build the qualified quality.
Customized production meet the individual requirement.
Prompt delivery & excellent after sales service.
Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.

5.Contact Information
James
KAIXIANG ELECTRICAL TECHNOLOGY CO.,LTD
FOREIGN TRADE DEPARTMENT
TEL:+86-0311-86125326
FAX:+86-0311-86128298
Mobile:+86-18332007067
Web:kxload.en.made-in-china.com
 
Add:No.79,Wangshan Road,Luquan District,Shijiazhuang,Hebei,China

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now