400V 5MW Genset Test Dummy Load Bank

Product Details
Customization: Available
After-sales Service: 12 Months
Rating Voltage: 400VAC
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • 400V 5MW Genset Test Dummy Load Bank
  • 400V 5MW Genset Test Dummy Load Bank
  • 400V 5MW Genset Test Dummy Load Bank
  • 400V 5MW Genset Test Dummy Load Bank
  • 400V 5MW Genset Test Dummy Load Bank
  • 400V 5MW Genset Test Dummy Load Bank
Find Similar Products

Basic Info.

Model NO.
AC400-5000kW
Rated Load Power
5000kw
Load Steps
250kw*20
Load Tolerance (Each Step)
5%
Load Tolerance(Overall)
3%
Dimension
6058*2438*2591mm
Cooling
Forced Air Cooling
Transportation
Hoisting
Max Protection Grade
IP55
Control Power
3 Phase 4 Wire 380V/50Hz
Transport Package
Container Type
Specification
ISO9001: 2008
Trademark
triumph load
Origin
Shijiazhuang, Hebei, China
HS Code
9030390000
Production Capacity
120sets/Year

Product Description

400V 5MW Genset Test Dummy Load BankIntroduction:400V 5MW Genset Test Dummy Load Bank400V 5MW Genset Test Dummy Load Bank400V 5MW Genset Test Dummy Load Bank
Resistance/inductance/capacity/Portable Intelligent load bank 
Intelligent AC load bank main used to test the capability and aging degree for high-power ups on-line, inverter, switch power and diesel generator set for electric power, telecom department and manufacturer. It can ensure the reliability of constant power charge that adopts uniformly stepped power input, energy consumption work model and forced air-cooling model. It is of high power density, no red hot phenomenon and automatic protection function overheated. It can't be overheated and broken when the fans stop working. The complete machine can be operated simply and maintain convenient that adopts module design. It can test voltage and current according to client's request, and provide scientific test measures for high-power AC equipment.
Main functions
1. Users can set adjustable discharge power according to capability parameter and test request.
2. Voltage and current value can be displayed with multi-functional digital meter.
3. AC load bank is of all kinds of specifications and series, and include resistance, inductive and capacitive load.
4. Two or more Intelligent AC Load Bank can operate in parallel.
5. It can make stable state test. 
6. Remote control by software.
 
400V 5MW Genset Test Dummy Load Bank
Rating Voltage/Frequency 400AC/50Hz, 3 phase 4 wire, 230V each phase
Rated Load Power Resistive load: 5000kW
Installed Capacity Resistive load: 5000kW
Load Step Resistive load: 20 steps, 250kW*20
PF(Power Factor) 1
Load Tolerance  (each step) ±5%
Load Tolerance(overall) ±3%
Display Precision 0.5 class
Control Power 3 phase 4 wire 380V/50Hz
Wire Connection Load power supply input--Copper bar (star coupling)
Control power supply input--Connector-bar
Insulation F
Max Protection Grade IP55
Way of Working Continuous Working
Cooling Forced air cooling,Horizontal inlet air,Vertical cooling
Aeration About 160,000 cubic meters per hour
Casing Structure Container, with a ladder, air inlet and outlet with mesh enclosure and protection door
Transportation Hoisting, there are lifting lug in top of casing
Casing Color Grey(RAL7035)or as per customer's requirement
Dimension About 6058 mm×2438mm×2591mm(length*width*height)
Weight About 11000kg
Operating Environment Parameter
Workplace Outdoor
Ambient Temperature -10ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤2500 meter
Atmospheric Pressure 86~106kPa
Space Required About 14.77 square meter
Ground load-bearing requirements About 406kg/square meter
Aeration Distance 3-5meters no obstacle from air inlet, more than 3meters no obstacle from air outlet
Safe Working Distance There must be isolation lairage 1 meter from load bank, and when load bank is working, no person allowed in 3-5 meter from load bank
Brands of Main Components
Contactor Schneider
Fuse DELIXI
Alloy Resistance Kaixiang(self-developed)
Data Processing Software Kaixiang(self-developed)
Application
Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test
400V 5MW Genset Test Dummy Load Bank400V 5MW Genset Test Dummy Load Bank

  
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier