Lead Acid Battery Charger Discharger Capacity Tester

Type: Storage Battery Tester
Test Region: All
Application: Lead-acid Battery
Customized: Customized
Brand: Triumph Load
Nominal Voltage: DC220V
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
C/F220-40
Charge Voltage
30-275V
Charge Current
4-40A
Discharge Voltage
30-275V
Discharge Current
1-40A
Charge Discharge Capacity
10-400ah
Discharge Time
1m---99h59m
Accuracy
Current--0.1A, Voltage --0.1V
Control Precision
±(0.3%+0.2A)
Transport Package
Wooden Case
Specification
0.5cbm
Trademark
Triumph Load
Origin
Hebei, China
HS Code
9030339000
Production Capacity
10000sets/Year

Product Description

Lead Acid Battery Charger Discharger Capacity Tester
1.Lead Acid Battery Charger Discharger Capacity Tester Introduction

Automatic charger/discharger can active any disabled single cell battery of 2V/6V/12V or activate the disabled battery of 1-24 section.It can increase disabled single cell capacity and battery life so that prevent broken battery 
hurt normal battery. Integrating charge and discharge in one, it can automatically achieve charge and discharge
process constant-voltage and constant-current after setting parameter.
2.Lead Acid Battery Charger Discharger Capacity Tester Features&Function
1).Display mode: LED display all parameters and test data in real-time with English menu. Display testing data: voltage, current, capacity charging time, discharging time etc.
2).Control pattern: Keyboard set all parameters: even charging voltage, under voltage protection, charging/discharging 
current, charging/discharging capacity charging /discharging time.
3).Operating mode: (1) Constant current discharging achieve the capacity test and load capacity test of the 
battery. (2) Intelligent three stages charging: Constant current-fixed voltage, reducing current-floating charging.
4).Automatic stop: It can stop testing automatically meet following conditions: test time out, testing capacity out, 
Over-current protection value and protective voltage out.
5).Automatic alarm function: When meet high temperature, opposing connection, battery wire disconnect, undervoltage, overvoltage, overcurrent, it will give a alarm.
6).Calibration correction function: Calibrate the charging/discharging voltage, charging/discharging current.
7).Modular design: Small size, convenient to carry, forced air cooling.
 3.Lead Acid Battery Charger Discharger Capacity Tester Technical Parameter

Model

C/F220-40

Charging voltage

30-275V

Charging current

4~40A

Discharging voltage

30-275V

Discharging current

1~40A

Load regulation

<1%

Voltage regulation

<0.1%

Ripple voltage

<1%

Timing range

1minutes-99hour59minutes

Overheat protection threshhold

80ºC~85ºC

Protection

Input overvoltage, under voltage; Output over voltage, over current, short circuit; overheat

Insulation resistor

≥20M

Working voltage

AC220V±5%;50HZ±5%

Size mm(L×H×D)

426×172×505mm

Weight(kg)

20
Lead Acid Battery Charger Discharger Capacity Tester
Lead Acid Battery Charger Discharger Capacity Tester

4.Why choosing us

The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
The most patent technology and scientific research awards gainer in China.
Advanced detection method and strict inspection procedure build the qualified quality.
Customized production meet the individual requirement.
Prompt delivery & excellent after sales service.
Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.
5.Contact Information



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.