100kw Resistor Load Bank for Generator Testing

Product Details
Customization: Available
Conditions
of Use:
Land Use
Usage: Standby Unit
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • 100kw Resistor Load Bank for Generator Testing
  • 100kw Resistor Load Bank for Generator Testing
  • 100kw Resistor Load Bank for Generator Testing
  • 100kw Resistor Load Bank for Generator Testing
  • 100kw Resistor Load Bank for Generator Testing
  • 100kw Resistor Load Bank for Generator Testing
Find Similar Products

Basic Info.

Model NO.
AC400-100
Output Type
AC Three Phase
Cooling
Method
Wind Cooling
Installation
Method
Fixed
Generator
Type
Diesel Generator
Voltage
AC400V
Frequency
50Hz
Rated Power
100kw
Insulation Grade
F Class
Transport Package
Plastic Film
Specification
860mm*570mm*770mm
Trademark
Triumph
Origin
Hebei China
Production Capacity
100/Month

Product Description

100kW Resistor Load Bank For Generator Testing

1.Product Introduction
AC400-100KW Intelligent Generator Testing System,AC Load Bank
It is designed for AC power maintenance,could be used widely in communication base,power supply,power 
station etc.This machine is small,light weight digital table display,easy operation,high intelligence, set the parameters of constant current discharge process can be done automatically.

2.AC400-100KW Intelligent Generator Testing System,AC Load Bank Working Environment
Altitute:≤2500m
Temperature:-10°C~50°C
Humidity:≤95%RH
Working Mode:Continuous work(>6hours continuous long-term work per day)
 
3.AC400-100KW Intelligent Generator Testing System,AC Load Bank Technical Specifications
 
Rating voltage/frequency AC400V 3 phase 4 wire, 50/60Hz
Max Load Power 100kW
Load Resolution 1kw,2kw,2kw,5kw,10kw,10kw,20kw,50kw
 
Power Factor 1
Load Tolerance ±5%
Load Tolerance ±3%
Display Meter Multiple function meter /Generator tester
Control source 220v 50Hz 1 phase 
Wire Connection Load bank input--Connector bar
Control power input--3-pin socket
Communication Interface RS232, RS485
Insulation F
Cooling Forced air, horizontal air intake and upwards exhaust cooling
Transportation With lifting eyes and wheel castors
Color As customer's requirements or as our design
Dimensions About 860mm*570mm*770mm L×W×H
Weight About 140kgs
Ambient Temperature -10°C~+50°C
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
PLC Siemens
Alloy Resistor Kaixiang

100kw Resistor Load Bank for Generator Testing
4.
Quality Inspection
The company has 140 employees, including 50 technicians and 25 senior technicians.It is a research and development team and production team composed of elite professionals. Provide the best technical service for customers
 100kw Resistor Load Bank for Generator Testing
5.company information

Kaixiang Technology was established in 1994, long-term focus on smart power detection technology development and application in shipbuilding, petroleum, offshore platforms, data centers, communications, power, aviation, research institutes and other areas, and in strict accordance with the ISO9001 international quality standard management system for the design, manufacture and service.

The company's core technologies are independent research, has seven patents, 10 software copyrights, two corporate standards.Among them, Kaixiang "smart power marine generators AC load," Science and Technology Department of Hebei Province has been named the international advanced level scientific and technological achievements, the enterprise standard "dry AC load" to upgrade the industry standard by the Ministry of publicity.

100kw Resistor Load Bank for Generator Testing
6.workshop
100kw Resistor Load Bank for Generator Testing
7.exhibition
100kw Resistor Load Bank for Generator Testing79

8. Why choosing us

  1. The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
  2. The most patent technology and scientific research awards gainer in China.
  3. Advanced detection method and strict inspection procedure build the qualified quality.
  4. Customized production meet the individual requirement.
  5. Prompt delivery & excellent after sales service.
  6. Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
  7. Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
  8. Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.

9. Contact Information
Marisa Ren
KAIXIANG ELECTRICAL TECHNOLOGY CO.,LTD
FOREIGN TRADE DEPARTMENT
 
  
Web:kxload.en.made-in-china.com
Add:No.79,Wangshan Road,Luquan District,Shijiazhuang,Hebei,China

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier