• Resistive and Inductive Load Bank 4000kVA AC Load Banks for Generator UPS Testing
  • Resistive and Inductive Load Bank 4000kVA AC Load Banks for Generator UPS Testing
  • Resistive and Inductive Load Bank 4000kVA AC Load Banks for Generator UPS Testing
  • Resistive and Inductive Load Bank 4000kVA AC Load Banks for Generator UPS Testing
  • Resistive and Inductive Load Bank 4000kVA AC Load Banks for Generator UPS Testing
  • Resistive and Inductive Load Bank 4000kVA AC Load Banks for Generator UPS Testing

Resistive and Inductive Load Bank 4000kVA AC Load Banks for Generator UPS Testing

After-sales Service: Forever
Warranty: 1 Year
Max Diameter of Workpiece: 300mm
Mass Scope of Workpiece: <900kg
Type: Electrical Performance Testing
Maxcapacity: >1000KN
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC400-4000KVA
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
>2000Kg
Power Source
AC380V
Oil Cylinder Position
No
Voltage
AC400V
Frequency
50/60Hz
Resistive Power
3200kw
Inductive Power
2400kvar
Rated Capacity
4000kVA
Insulation Grade
F Class
Cooling
Forced Air Cooling, Horizontal Inlet Air, Upward C
Protection Class
IP54
Transport Package
Container
Specification
6058*2438*2750mm
Trademark
Triumph Load
Origin
Hebei, China
HS Code
9030339000
Production Capacity
10000 Sets/ Year

Product Description

Resistive and Inductive Load Bank 4000kVA AC Load Banks for Generator UPS Testing
1.Product Introduction
AC 400V Resistive and Inductive Combined Loadbank 4000kVA
High Power Dry Type Load Bank is composed of outdoor resistive and inductive combined load bank,data collection system,electric control module,thermal module,control part etc.It can accurately detect Marine generator output power and load capacity,and assist shipyard in acceptance of vessel,mooring test,sea trial,load test,static voltage characteristic test, speed characteristic test,overload protection test,reverse power and reverse current protection test,and parallel operation test etc.

2. AC 400V Resistive and Inductive Combined Loadbank 4000kVA System Chart

Resistive and Inductive Load Bank 4000kVA AC Load Banks for Generator UPS Testing

3. AC 400V Resistive and Inductive Combined Loadbank 4000kVA Working Environment
Altitute:≤2500m
Temperature:-10°C~50°C
Humidity:≤95%RH
Working Mode:Continuous work(>6hours continuous long-term work per day)
4.Resistive and Inductive Load Bank 4000kVA load banks for generator UPS testing

Technical parameter

AC400-4000KVA-RL

Rated voltage /Frequency

Three-phase three-wire 400V, 50/60Hz

Rated Capacity

4000KVA

Load Distribution

 When 400V/60Hz: Resistive load: 3200kW,Inductive load: 2400Kvar

 

Stepping Value

Resistive load: 1KW    Inductive load: 1Kvar

 

Resistor divider file

1KW, 2KW, 2KW, 5KW, 10KW, 20KW, 20KW, 50KW, 100KW, 200KW*15steps

Reactance file

1Kvar, 2Kvar, 2Kvar, 5Kvar, 10Kvar, 20Kvar, 20Kvar, 50Kvar, 100Kvar,  200Kvar*11steps

Power factor

0.8-1

Load Tolerance(each step)

±5%

Load Tolerance(overall)

±3%

Display Precision

0.5 class

Control Power Supply

External AC three phase connection 380V/50Hz 

Wire Connection

Load power supply input--Copper bar (star coupling)

Control power supply input--Connector-bar

Insulation grade

F class

Duty cycle

Continuous

Cooling

Forced air cooling, Horizontal inlet air, Vertical cooling 

Transportation

Hoisting, there are lifting lug in top of casing and casters in bottom of load bank

Casing Color

Grey(RAL7035)

Dimension

About 6058mm*2438mm*2750mm(length*width*height)

Weight

About 18000kg

Operating Environment Parameter

Ambient Temperature

-10ºC~+50ºC

Relative Humidity

≤95%

Altitude

≤2500 meters

Atmospheric Pressure

86~106kPa

Main components brand

 

 

Circuit Breaker

Siemens

Fuse

Delixi

SCM

Infineon

Alloy Resistor

Kaixiang

Data Management Software

Kaixiang

Testing Function  
(1) Stable-state Test:
 load power in rated range, measure generator steady-state 3 phase voltage, current, active power, reactive power, apparent power, power factor, frequency, and running time.
(2) One-key load/unload: no mattery using software control or manual control, can set loading power first, then press master load switch, this avoid the load fluctuation.
(3) Setting Test: can catch the max and min setting value of voltage and frequency, and calculate the relative setting up and down range of voltage and frequency and adjustment rate within 100 seconds setting time.
(4) Fluctuation Test: catch the max and min fluctuating value of voltage and frequency, and calculate steady-state frequency band, steady-state voltage deviation, voltage modulation, fluctuation rate and frequency in 60 seconds fluctuation time.
(5) Transient Test (Instant Load Test): sample interval is 40μs,system catch the transient max and min value and recovery time of voltage, current, and frequency, and calculate instant load transient voltage deviation and instant load transient frequency deviation.
(6) Transient Test (Instant Unload Test): sample interval is 40μs,system catch the transient max and min value and recovery time of voltage, current and frequency,  and calculate instant unload transient voltage deviation and instant unload transient frequency deviation.
(7) Harmonic Analysis: It can analysis 2~50 harmonic content and total harmonic content in voltage and current at same time.
(8) Record Wave Analysis: 5 patterns for recording voltage real-time waveform, and the record time is 4~ 280 seconds and accurately sampling at 128 points in a wave cycle at most.

5. Resistive and Inductive Load Bank 4000kVA load banks for generator UPS testing
Overall Apperance
Resistive and Inductive Load Bank 4000kVA AC Load Banks for Generator UPS Testing
Resistive and Inductive Load Bank 4000kVA AC Load Banks for Generator UPS TestingResistive and Inductive Load Bank 4000kVA AC Load Banks for Generator UPS Testing
    



 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now