• AC440-600kw Intelligent Alloy Resistive Load Bank
  • AC440-600kw Intelligent Alloy Resistive Load Bank
  • AC440-600kw Intelligent Alloy Resistive Load Bank
  • AC440-600kw Intelligent Alloy Resistive Load Bank
  • AC440-600kw Intelligent Alloy Resistive Load Bank

AC440-600kw Intelligent Alloy Resistive Load Bank

Accuracy Grade: 0.5
Display: Digital
Control: Computer Control
Weight: 1000-2000Kg
Power Source: AC440
Rated Voltage: AC440V
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC440-600kW
Cooling
Forced Air Cooling
Working Mode
Continuous
Ambient Temperature
-10ºC~+50ºC
Transport Package
Wooden Case
Specification
1650*1350*1680mm
Trademark
TriumphLoad
Origin
China
HS Code
9030390000
Production Capacity
1000sets/Year

Product Description

AC440-600kW Intelligent Alloy Resistive Load Bank
 

Introduction

Thank you for using AC440-600kW Intelligent Load Bank. The system accurately test output power and load capacity of all kinds of generators, main electrical parameters including the dynamic parameters tested.

 

Technical Parameters

 

Technical Parameters

Rating Voltage/Frequency

AC 3phase 4wire 440V 50Hz

Max Load Power

Resistive Load: 600kW

Load Step

Resistive Load:11 steps; 1,2,2,5,10,10,20,50,100,200,200kW

Power Factor

1

Load Tolerance(each step)

±5%

Load Tolerance(overall)

±3%

Display Precision

0.5 class

Control Power Supply

3 phase 4 wire 415V/50Hz

Wire Connection

Load Power Supply Input--Copper bar (star connection)

Control power supply input--Wiring row

Communication Interface

RS485, RS232

Insulation Class

F

Working Mode

Continuous Working

Cooling

Forced air cooling,Horizontal inlet air,Horizontal outlet

Transportation

Hoisting, there are lifting lug in top of case and wheel castors in bottom

Casing Color

Grey(RAL7035)

Dimension

Approximately; 1650*1350*1680

(Width *Length *Height)

Weight

About 900kg

Operating Environment Parameter

Ambient Temperature

-10ºC~+50ºC

Relative Humidity

≤95%

Altitude

≤2500 meters

Atmospheric Pressure

86~106kPa

 

Measuring Control Function

--Load testing: load power that not beyond the rated power, testing and display stable state 3 phases voltage, current, active power, frequency, working time, etc of generator sets.

--Load/unload with one key: Whether manual control, remote control or software control, user can preset the power, then press load master button. Load bank loaded according to preset power to avoid load fluctuation during the power changing.

--Control Pattern: user can choose local control and intelligent control.

--Local Control: There is local control panel with several power steps; user can load/unload by button.

--Intelligent Control: Through data processing software in PC, user can make automatic load, to display, record and manage the testing data, to form curves, tables, also to print them.

--Control Pattern interlock, there is control pattern switch, when choose one control pattern, operation of other pattern is invalid, avoid the clash.

--Local meter display data: local meter can display 3 phases voltage, current, active power, frequency and so on.

 

Software Function

--Communication pattern: Intelligent control use photoelectric isolated RS485 interface connect to PC, with great anti-interference performance to make system control stable. Also user can use USB or RS232 through converter.  

--Load pattern: Manual Load or Automatic Load.

--Manual Load: Input power, system will load according to preset power.

--Automatic load: user can preset power and length of working time of several load periods, as per 0%→25%→50%→75%→100% or 110% to make testing.

--Parallel testing: when several load bank work in parallel, use can make parallel testing via software, can display, record parameters of every load bank and whole system parameter of parallel operation.

--Real-time parameter: through software to display voltage, current, power, power factor, frequency and time, etc.

--Security monitoring and control: monitor working state of the load bank by watching software light, when abnormally stop and protect, it can show the reason.

--Data save and query: all the test data is saved in the software, easy to query in the history testing data.

--Data Collection Interval: the minimum steady-state data resolving time is 1 seconds.

--Graphical display: show real-time or history testing data, and support to print curve and graph as follows:

1) Graphs of real-time voltage, current, frequency and power; 2) Voltage graph

3) Current graph; 4) Power graph; 5) Frequency graph; 6) Power factor graph

--Data format: all the curves and graphs can be outputted as".doc"format, testing data can be outputted as ".xls" format, and can be printed.

 

Protection

--Emergency stop: you can press the Emergency Stop switch in the panel, when the load bank is locked in this state, it cannot add any load.  

--Overvoltage protection: when input voltage is over the safe value, it can unload automatically and give an alarm.

--Short circuit protection: when short circuit, fuses in the load bank can insure to unload automatically.

--Overheating protection: when temperature is over the safe value, it can unload automatically and give an alarm.

--Fan interlock protection: load bank cannot add any load when working power of fan is off.

--Overload Protection With Fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.

--Phase sequence protection of fans: 3phase fans still running although there is a wrong phase connect of control power.

--Protection Buttons: There are buttons for some protection, when misinformation occurs or user has special needs, user can temporarily turn off the corresponding protection function.

--Chassis Ground Protection: in order to avoid the danger of electric shock when operating, the load bank is equipped with special ground protection terminal.

 

Why choosing us

The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
The most patent technology and scientific research awards gainer in China.
Advanced detection method and strict inspection procedure build the qualified quality.
Customized production meet the individual requirement.
Prompt delivery & excellent after sales service.
Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.

Contact us

Kaixiang Electrical Technology Co., Ltd       
          James Lee
        Sales   Manager
 
No 33 Wangshan Road, Shijiazhuang City, 
Hebei Province, China
Tel: 0086-311-85138355 Fax: 0086-311-85138383
Cell phone: 86-18332007067
kxload.en.made-in-china.com  

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now