3 Phase 2000kw AC Programmable Load Banks for Genset Testing

Product Details
Customization: Available
Rated Load Power: Resistive Load: 2000kw
Rating Voltage: 400VAC/50Hz
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • 3 Phase 2000kw AC Programmable Load Banks for Genset Testing
  • 3 Phase 2000kw AC Programmable Load Banks for Genset Testing
  • 3 Phase 2000kw AC Programmable Load Banks for Genset Testing
  • 3 Phase 2000kw AC Programmable Load Banks for Genset Testing
  • 3 Phase 2000kw AC Programmable Load Banks for Genset Testing
  • 3 Phase 2000kw AC Programmable Load Banks for Genset Testing
Find Similar Products

Basic Info.

Model NO.
AC load bank
Power Factor
1
Control Power
3 Phase 4 Wire 380VAC/50Hz
Duty Cycle
Continuous
Control Mode
Manual, Remote, Software
Cooling
Forced Air Cooling by Fan
Transport Package
Container Structure
Specification
ISO9001: 2008
Trademark
Triumph load
Origin
Shijiazhuang, Hebei, China
HS Code
9030390000
Production Capacity
150sets/Year

Product Description

Introduction:

Resistance/inductance/capacity/Portable Intelligent load bank
Intelligent AC load bank main used to test the capability and aging degree for high-power ups on-line, inverter, switch power and diesel generator set for electric power, telecom department and manufacturer. It can ensure the reliability of constant power charge that adopts uniformly stepped power input, energy consumption work model and forced air-cooling model. It is of high power density, no red hot phenomenon and automatic protection function overheated. It can't be overheated and broken when the fans stop working. The complete machine can be operated simply and maintain convenient that adopts module design. It can test voltage and current according to client's request, and provide scientific test measures for high-power AC equipment.

Main functions

1. Users can set adjustable discharge power according to capability parameter and test request.
2. Voltage and current value can be displayed with multi-functional digital meter.
3. AC load bank is of all kinds of specifications and series, and include resistance, inductive and capacitive load.
4. Two or more Intelligent AC Load Bank can operate in parallel.
5. It can make stable state test.
6. Remote control by software.
7. Testing data can be saved or transferred by RS485, data can form curve, to be printed.

Function options

Intelligent AC Load Bank has two control patterns: position machine software control and local panel control
Intelligent AC load bank (LED): multi-function digital special meter of 0.5 step can be test and display: AC voltage, current, active power, power factor and frequency. It can communicate with PC via RS485 interface.
Intelligent AC load bank (LCD): Special LCD meter display: AC voltage, current, active power, power factor and voltage frequency. It is of the harmonic analysis function of 1-40 times, and can communicate with PC via RS485 interface.

Technical Parameter
 
AC400-2000kW Automatic Load Bank
Rating Voltage/Frequency 400VAC/50Hz, 3 phase 4 wire, line voltage 400V, phase voltage 230V
Rated Load Power Resistive load: 2000kW
Installed Capacity Resistive load: 2000kW
Load Step 1,2,2,5,10,10,20,50,100,200kW*9, total 18 steps, min step load: 1kW for each set of 2000kW load bank.
PF(Power Factor) 1
Load Tolerance  (each step) ±5%
Load Tolerance(overall) ±3%
Display Precision 0.5 class
Control Power 3 phase 4 wire 380VAC/50Hz
Wire Connection Load power supply input--Copper bar (star coupling)
Control power supply input--Connector-bar
Insulation F
Way of Working Continuous Working
Casing Dimensions and Cooling Forced air cooling,Horizontal inlet air,Vertical cooling
about 6058*2438*2591mm (L*W*H) for 1 set of 2000kW load bank
Weight About 4000kgs
Transportation Hoisting, there are lifting lug in top of casing
Casing Color Grey(RAL7035)
Operating Environment Parameter
Workplace Outdoor
Ambient Temperature -10ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤2500 meter
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor CHINT
Fuse DELIXI
Alloy Resistance Kaixiang(self-developed)

Who we are
 
Hebei Kaixiang Electrical Technology Co., Ltd is a leading manufacturer in emergency power supply test & maintenance industry. Specialized in the design, R&D, manufacture of the high capacity AC & DC load bank, it owns the largest intelligent power supply testing equipment R & D centre in China. We offer one-stop solutions to generator set & battery & UPS power manufacturers. Our products are widely used in data centre, shipbuilding, offshore platform, state grid, nuclear power, hospital, communication, railway, war industry etc filed. We are strategy partner of many famous company, such as Cummins, Caterpillar, Kohler, Jiangnan Shipyard, CSSC,CSIC, State grid, China mobile, Tecent, Baidu, Sinopec, CETC etc. Some of our products have been exported to Singapore, Japan, United Kingdom, Saudi Arabia, Australia, South Korea, Thailand, Angola etc. Through years of development, "Triumph Load" already the first brand in power supply detection industry in China.
 
What we can do
 
1. Professional technical team with more than 20 years design experience.
2. Customized technical solutions meet customer's individual requirements.
3. Skilled workman insure the reliable assembly technology.
4. Strict inspection procedures throughout the whole production flow.
5. Prompt delivery make sure the customers receive the goods on time.
6. Perfect after sales service create good user experience.
7. Reliable quality & competitive price maximize profits for customers.
8. Timely feedback save valued time for the customer.
9. Humanized management system build homelike work atmosphere.
10. Certified with CCS and ISO9001:2008 Quality Certificate.
 
3 Phase 2000kw AC Programmable Load Banks for Genset Testing
3 Phase 2000kw AC Programmable Load Banks for Genset Testing
3 Phase 2000kw AC Programmable Load Banks for Genset Testing
3 Phase 2000kw AC Programmable Load Banks for Genset Testing
3 Phase 2000kw AC Programmable Load Banks for Genset Testing
3 Phase 2000kw AC Programmable Load Banks for Genset Testing
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier