10.5kv 2000kw High Voltage Load Bank for Generator UPS Testing

Product Details
Customization: Available
Conditions
of Use:
Land Use
Usage: Common Units
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • 10.5kv 2000kw High Voltage Load Bank for Generator UPS Testing
  • 10.5kv 2000kw High Voltage Load Bank for Generator UPS Testing
  • 10.5kv 2000kw High Voltage Load Bank for Generator UPS Testing
  • 10.5kv 2000kw High Voltage Load Bank for Generator UPS Testing
  • 10.5kv 2000kw High Voltage Load Bank for Generator UPS Testing
  • 10.5kv 2000kw High Voltage Load Bank for Generator UPS Testing
Find Similar Products

Basic Info.

Model NO.
10.5KV 2000KW AC
Output Type
AC Three Phase
Cooling
Method
Air Cooled
Installation
Method
Container
Generator
Type
Generator Test
Voltage
AC10.5kv
Frequency
50Hz
Rated Power
2000W
Insulation Grade
F Class
Protection Grade
IP54
Transport Package
Container
Specification
6058mm*2438mm*2591mm (L* W* H)
Trademark
Triumph Load
Origin
Hebei, China
HS Code
903033900
Production Capacity
1000 Sets/Year

Product Description

10.5kv 2000kw High Voltage Load Bank for Generator Ups Testing
1.Product Introduction

AC10.5KV 2000KW High Voltage Load Bank For Generator Set Testing
High voltage load bank,the optional voltage range is 6.6KV~35KV,can be directly used for large high voltage 
generator,need not to be equipped with conventional step down transformer.We can also provide regular load
bank for high voltage equipment,need to use step-down transformer together.
2.AC10.5KV-2000KW High Voltage Load Bank Application
Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current 
protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading systemPeriodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
3.AC10.5KV-2000KW High Voltage Load Bank for Generator Set Working Environment
Altitute:≤2500m
Temperature:-10°C~50°C
Humidity:≤95%RH
Working Mode:Continuous work(>6hours continuous long-term work per day)
4. AC10.5KV-2000KW High Voltage Load Bank for Generator Set Technical  Specifications

Load a single set of system parameters

Rated voltage 
and frequency

AC 3 phase 4 wire, 10.5KV/50Hz

Maximum load power

Resistive Load: 2000KW

Load Resolution

100KW,200KW,200KW,500KW,500KW,500KW,6steps

Power Factor

1

Load accuracy (per file)

± 5%

Load accuracy (whole)

± 3%

Display accuracy

0.5

Control Power

External AC 3 phase 4 wire, 380V/50Hz

Wire Connection 

Load bank input--Copper bar (star coupling "Y")
Control power input--Connector-bar

Wiring port design

Allow sufficient space to ensure that users can easily access the load cables.
External load penetrating openings in the cables after the cables have sufficient 
waterproof capability, and sufficient mechanical strength.

Communication Interface

RS485, RS232

And machine methods

Computer software and machine

Insulation class

Class F

Protection class

IP55

Noise

3 m away from the outlet is less than 9 0 db

Way of Working

Continuous working

Cooling

Forced air cooling, horizontal inlet air, vertical exhaust cooling

Chassis construction

Container package, with up to the top of the ladder, with inlet and outlet 
grilles and door protection

Enclosure

Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door

Transportation

Hoisting, there are lifting lug in top of casing

Chassis Size

Approximately 5000mm × 2500mm × 2896mm (L × W × H)

Weight

Approximately 6000kg

Work environment parameters

Workplace

Coastal areas, outdoor work

Operating Temperature

- 25 ºC ~ + 6 0 ºC (lower limit of the instrument's temperature-10 ºC)

Relative Humidity

≤ 95%

Altitude

≤ 2500m

Atmospheric pressure

86 ~ 106kPa
10.5kv 2000kw High Voltage Load Bank for Generator UPS Testing
10.5kv 2000kw High Voltage Load Bank for Generator UPS Testing

5.Why choosing us
The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
The most patent technology and scientific research awards gainer in China.
Advanced detection method and strict inspection procedure build the qualified quality.
Customized production meet the individual requirement.
Prompt delivery & excellent after sales service.
Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.

10.5kv 2000kw High Voltage Load Bank for Generator UPS Testing10.5kv 2000kw High Voltage Load Bank for Generator UPS Testing
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier