1250kw Resistive Load Bank for Generator UPS Testing

Rated Voltage: 400V 3phase 4wire 50Hz
Rated Power: 1250kw
Duty Cycle: Continuous
Dimension: 2660mm*1600mm*2100mm
PF: 1
Cooling: Air Cooled
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC400-1250kW
Trademark
Triumph Load
Origin
China
HS Code
9030339000
Production Capacity
10set/Month

Product Description

2.3 Test Function

(1) Steady-state Test: load power in rated range, measure generator steady-state 3 phase voltage, current, active power, reactive power, apparent power, power factor, frequency, and running time.
(2) Setting Test: acquisition the max and min setting value of voltage and frequency, calculate the relative setting up and down range of voltage and frequency, adjustment rate within 100 seconds setting time.
(3) Fluctuation Test: catch the max and min fluctuating value of voltage and frequency, and calculate steady-state frequency band, steady-state voltage deviation, voltage modulation, fluctuation rate and frequency in 60 seconds fluctuation time.
(4) Transient Test(Instant Load Test): sample interval is 40μs,system catch the transient max and min value and recovery time of voltage, current, and frequency, and calculate instant load transient voltage deviation and instant load transient frequency deviation.
(5) Transient Test(Instant Unload Test): sample interval is 40μs,system catch the transient max and min value and recovery time of voltage, current and frequency,  and calculate instant unload transient voltage deviation and instant unload transient frequency deviation.
(6) Harmonic Analysis: Analysis 2~50 harmonic content and total harmonic content in voltage and current at same time.
(7) Record Wave Analysis: 5 patterns for recording voltage real-time waveform, and the record time is 4~280 seconds, and accurately sampling at 128 points in a wave cycle at most.

 

2.4 Control and Display

(1) Control mode: user can choose local control, remote control or intelligent control (PC control)
(2) Local control:The load bank is equipped with a local panel, including power-on instructions, fan operation instructions, loading instructions, fault instructions, and emergency stop. You can select the control mode, internal and external working power through other selection switches, the touch screen displays data (three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency, temperature) and control power gear, touch screen data U disk can be exported via USB for viewing by computer.
(3) Remote control:Load bank can be controlled by remote handheld control box.
(4) Intelligent control: user can control load bank by data processing software of PC to make automatic load/unload, display, record and manager the test data, form curve, graph, also can be printed.
(5) Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.
(6) One-touch load increase and decrease: No matter when using manual switch or software control, you can set the power value first, and then start the total load switch, the load bank will be loaded according to the preset value, thereby avoiding load fluctuation during power adjustment.
(7) Local meter display data: 3 phase voltage, current, active power, reactive power, apparent power, power factor, frequency etc.
(8) Load bank temperature detection function: the temperature of the air outlet in the load bank power consumption component warehouse can be displayed through the temperature meter (the meter is not placed on the panel).
(9) Phase loss test function: During the user phase loss protection function test, the disassembly of the fuse with a base with an additional high current is completed, and the fuses of each gear level are retained.
System Parameters
Rated Voltage/
Frequency
3phase 4wire, 400VAC/50Hz
MAX Power (AC440V) Resistive:1250kW
Steps
(AC440V)
Resistive load: 15 steps,
1,2,2,5,10,10,20,50,50,100,200,200,200,200,200kW.
Noted:
When the input voltage is lower than the rated voltage, the load bank gear power decreases according to Ohm's law.
PF 1
Precision  (each step) ±5%
Precision     (Overall) ±3%
Display Precision 0.5 class
Auxiliary Power Internal and external connection (local control panel with internal/external switch)
AC 3phase 4wire AC400V/50Hz,About15kW.
Wiring Load input--Copper Bar(Star)
Auxiliary Power--Line Bank
Communication RS485
Insulation F
Working Continuity
Cooling Air cooled,horizontal air intake,vertical air outlet
Container packaging,ladder at the front side, window with mesh
Transport hoist,lifting eye on the top
Container Color Grey (RAL7035)
Dimension 2660mm×1600mm×2100mm(L×W×H)
Weight Around 1500KG
Environment
Working environment Outdoor

1250kw Resistive Load Bank for Generator UPS Testing
1250kw Resistive Load Bank for Generator UPS Testing
1250kw Resistive Load Bank for Generator UPS Testing
1250kw Resistive Load Bank for Generator UPS Testing
1250kw Resistive Load Bank for Generator UPS Testing
1250kw Resistive Load Bank for Generator UPS Testing
1250kw Resistive Load Bank for Generator UPS Testing
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now