Rated Voltage: 400VAC, 3phase 4wire, 50Hz
Apparent Power: 2500kVA
Resistive Power: 2000kw
Inductive Power: 1500kvar
PF: 0.8
Cooling Type: Forced Air Cooling
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC400-2500KVA
Duty Cycle
Continuous
Dimension
6058*2350*2591mm
Trademark
Triumph Load
Origin
China
HS Code
9030339000
Production Capacity
5units/Month

Product Description

Rated Voltage: 400V, 3 phase 4 wire, 50HZ. Apparent Power: 2500KVA, Resistive Power: 2000KW, Inductive Power: 1500KVAR. Load Type:Resistive Inductive Integrated. PF: 0.8. Cooling: Forced air cooling. Duty Cycle: Continuous. Dimension: 6058*2350*2591mm. Protection: IP55. Load Resolution: 1kW/1KVAR. Control Mode: Manual/remote/PC. Display Parameters: voltage, current, power, PF, frequency. Guarantee: 1 year. 

Introduction of 2500KVA Resistive Inductive Load Bank(PF 0.8):

Resistance/inductance/capacity/Portable Intelligent load bank 

Intelligent AC load bank main used to test the capability and aging degree for high-power ups on-line, inverter, switch power and diesel generator set for electric power, telecom department and manufacturer. It can ensure the reliability of constant power charge that adopts uniformly stepped power input, energy consumption work model and forced air-cooling model. It is of high power density, no red hot phenomenon and automatic protection function overheated. It can't be overheated and broken when the fans stop working. The complete machine can be operated simply and maintain convenient that adopts module design. It can test voltage and current according to client's request, and provide scientific test measures for high-power AC equipment.

Main functions of 2500KVA Resistive Inductive Load Bank

1. Users can set adjustable discharge power according to capability parameter and test request.

2. Voltage and current value can be displayed with multi-functional digital meter.

3. AC load bank is of all kinds of specifications and series, and include resistance, inductive and capacitive load.

4. Two or more Intelligent AC Load Bank can operate in parallel.

5. It can make stable state test. 

6. Remote control by software.

7. Testing data can be saved or transferred by RS485, data can form curve, to be printed. 

Function options of 2500KVA Resistive Inductive Load Bank

Intelligent AC Load Bank has two control patterns: position machine software control and local panel control

Intelligent AC load bank (LED): multi-function digital special meter of 0.5 step can be test and display: AC voltage, current, active power, power factor and frequency. It can communicate with PC via RS485 interface.

Intelligent AC load bank (LCD): Special LCD meter display: AC voltage, current, active power, power factor and voltage frequency. It is of the harmonic analysis function of 1-40 times, and can communicate with PC via RS485 interface.
Technical Parameter

System Parameter
Rating voltage/frequency 400V, 3 phase 4 wire 50Hz
Max Load Power Apparent Power: 2500KVA 
Resistive Load: 2000kW
Inductive Load: 1500KVAR
Load Resolution Resistive Load: 18 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,200kW,200kW,200kW, 200kW,200kW,200kW,200kW,200kW,200kW  
Inductive Load: 16 steps  
1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR,100KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR,200KVAR
Power Factor 0.8(lag)
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External AC 3 phase 4 wire, 380V/50Hz  
Wire Connection Load bank input--Copper bar (star coupling "Y")
Control power input--Connector-bar
Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP54
Duty Cycle Continuous  
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions About 6058mm×2350mm×2591mm(L×W×H)
Operating Environment Parameter
Workplace  Outdoor  
Ambient Temperature -10ºC~+50ºC
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor   Schneider
Fuse  Miro
PLC  Siemens
Alloy Resistor   Kaixiang
Data Processing Software  Kaixiang

Pictures of 2500KVA Resistive Inductive Load Bank
2500kVA Resistive Inductive Load Bank
2500kVA Resistive Inductive Load Bank
2500kVA Resistive Inductive Load Bank
2500kVA Resistive Inductive Load Bank
2500kVA Resistive Inductive Load Bank
2500kVA Resistive Inductive Load Bank

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now