• Dummy Load Bank for Generator Testing
  • Dummy Load Bank for Generator Testing
  • Dummy Load Bank for Generator Testing
  • Dummy Load Bank for Generator Testing
  • Dummy Load Bank for Generator Testing

Dummy Load Bank for Generator Testing

Conditions
of Use:
Trailer Type, Marine, Land Use
Output Type: AC Three Phase
Cooling
Method:
Air Cooled
Installation
Method:
Portable
Generator
Type:
Steam Turbine Generator
Rating Voltage: AC 11kv 3 Phase 3 Wire
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC11kV-21MW
Frequency
50Hz
Load Step
6 Steps
Power Factor
1
Ambient Temperature
-10ºC~+50ºC
Relative Humidity
≤95%
Transport Package
Container
Specification
6058 mm*2438mm*2591mm
Trademark
Triumph Load
Origin
Hebei, China (Mainland)
Production Capacity
200 Set/Sets Per Year

Product Description

Introduction

The load bank includes 3 sets of 20'FT container type load banks, the steps are 4MW (500kW+500kW+1000kW+2000kW),4MW and 4MW. Each step connect outgoing copper bar to connect customer's high voltage cable. Alarm signal and fan control are outgoing by dry touch point terminal block.

Technical Parameters

 System Parameters

Rating voltage/frequency

AC 11KV 3 phase 3 wire, 50Hz

Max Load Power

Resistive Load: 12MW

Load Step

Resistive Load: 6 steps, 500,500,1000,2000,4000,4000kW

Power Factor

1

Load Tolerance  (each step)

±5%

Load Tolerance  (overall)

±3%

Fan Control Power

External input 380VAC 3 phase 4 wire, 50Hz /80KVA

Wiring

Load bank input--Copper bar (star coupling "Y")

Control power input--Connector-bar

Insulation Grade

F grade

Way of Working

Continuous Working

Cooling

Forced air cooling, horizontal inlet air and upwards exhaust cooling, install rainproof shelter

Transportation

Hoisting, there are lifting eyes in top of case

Case Color

Grey RAL7035

Dimensions

About 6058 mm*2438mm*2591mm (L×W×H)

Weight

About 7000kg

 Operating Environment Parameter

Ambient Temperature

-10ºC~+50ºC

Relative Humidity

≤95%

Altitude

≤2500 meters

Atmospheric Pressure

86~106kPa

Brands of Main Components

low voltage contactor

SCHNEIDER or SIEMENS

Low voltage fuse

DELIXI

Alloy Resistor

(self-developing)

Spare Parts

Alloy Resistor

5 for each type

Temperature Control Switch

***

Main Functions

1.Loading test: User could load any power within rated power to test the output capabilites of generator set.

2.Control mode: Copper bars are reserved, user can control through the switch.

3.Fan start: Dry touch point terminal block are reserved, the loading signal will be given before loading to dissipation heating in time.

4.Temperature protection: When load bank temperature is over threshold limited values, it alarms and notify customer through dry touch point.

5.Fan Protection: If insufficient air volume occurs, system will alarm automatically andnotify customer through dry touch point.

6.If any fan can't work in good condition, it alarms and notify customer through dry touch point.

 7.When control power cable in wrong connections, 3 phase fans can also work in good conditions.

 8.Protection button: there are some protection buttons can be switched off when false alarm or for special requirements.
Dummy Load Bank for Generator Testing
Dummy Load Bank for Generator Testing

Why choosing us
Dummy Load Bank for Generator Testing
Dummy Load Bank for Generator Testing
Dummy Load Bank for Generator Testing
Dummy Load Bank for Generator Testing
Tontact us

Kaixiang Electrical Technology Co., LTD.
Eric Zhang
  
ADD:33Wangshan Rd,Luquan District,Shijiazhuang,Hebei,050221,P.R.China
TEL:+86 311 85138355
FAX:+86 311 85138383
M.T.:+86 18937738282
Our service is beyond of products,but the feeling of customers

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now