The load bank includes 3 sets of 20'FT container type load banks, the steps are 4MW (500kW+500kW+1000kW+2000kW),4MW and 4MW. Each step connect outgoing copper bar to connect customer's high voltage cable. Alarm signal and fan control are outgoing by dry touch point terminal block.
System Parameters |
||
Rating voltage/frequency |
AC 11KV 3 phase 3 wire, 50Hz |
|
Max Load Power |
Resistive Load: 12MW |
|
Load Step |
Resistive Load: 6 steps, 500,500,1000,2000,4000,4000kW |
|
Power Factor |
1 |
|
Load Tolerance (each step) |
±5% |
|
Load Tolerance (overall) |
±3% |
|
Fan Control Power |
External input 380VAC 3 phase 4 wire, 50Hz /80KVA |
|
Wiring |
Load bank input--Copper bar (star coupling "Y") Control power input--Connector-bar |
|
Insulation Grade |
F grade |
|
Way of Working |
Continuous Working |
|
Cooling |
Forced air cooling, horizontal inlet air and upwards exhaust cooling, install rainproof shelter |
|
Transportation |
Hoisting, there are lifting eyes in top of case |
|
Case Color |
Grey RAL7035 |
|
Dimensions |
About 6058 mm*2438mm*2591mm (L×W×H) |
|
Weight |
About 7000kg |
|
Operating Environment Parameter |
||
Ambient Temperature |
-10ºC~+50ºC |
|
Relative Humidity |
≤95% |
|
Altitude |
≤2500 meters |
|
Atmospheric Pressure |
86~106kPa |
|
Brands of Main Components |
||
low voltage contactor |
SCHNEIDER or SIEMENS |
|
Low voltage fuse |
DELIXI |
|
Alloy Resistor |
(self-developing) |
|
Spare Parts |
||
Alloy Resistor |
5 for each type |
|
Temperature Control Switch |
*** |
1.Loading test: User could load any power within rated power to test the output capabilites of generator set.
2.Control mode: Copper bars are reserved, user can control through the switch.
3.Fan start: Dry touch point terminal block are reserved, the loading signal will be given before loading to dissipation heating in time.
4.Temperature protection: When load bank temperature is over threshold limited values, it alarms and notify customer through dry touch point.
5.Fan Protection: If insufficient air volume occurs, system will alarm automatically andnotify customer through dry touch point.
6.If any fan can't work in good condition, it alarms and notify customer through dry touch point.
7.When control power cable in wrong connections, 3 phase fans can also work in good conditions.
8.Protection button: there are some protection buttons can be switched off when false alarm or for special requirements.