500kVA Load Bank to Test Generator

Voltage: 400V,415V,480V,690V
Power: 500kw
Frequency: 50Hz, 60Hz
PF: 1
Min Step: 1kw
Communication: RS485, RS232
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC400-500KVA
Control
Local and Remote
Warranty
12 Months
Transport Package
Wooden Case
Specification
ISO, CE
Trademark
Triumph Load
Origin
China
HS Code
90303900
Production Capacity
500units

Product Description

500kW Load Bank
 
Main functions:
1. Users can set adjustable load power within rated power.
2. Current, voltage, frequency, power factor, and active power, reactive power, and apparent power can be displayed.
3. With software programmable control, graphs of current, voltage, frequency, power factor, power can be displayed, saved and printed.
Control mode: manual control (control panel) with remote controller box or PC control.
Display meters: multi-function digital meter or generator tester.
Protection: Over load protection, over heat protection, short circuit protection, Emergency stops switch, etc
 
Technical Parameter
Rating voltage/frequency 400VAC power 500kW; 3 phase 4 wire, 50Hz
Max Load Power 500kW
Load Resolution Resistive 100kW: 1, 2, 2, 5, 10, 10, 20, 50, 100, 100, 200kW
Power Factor 1
Load Tolerance  (each step) ±5%
Load Tolerance (overall) ±3%
Display Meter Multiple function meter /Generator tester
Fan Control Power External power 400VAC 3 phase 4 wire 50Hz
Wire Connection Load bank input--busbar (star coupling "Y")
Control power input--terminal block
Communication Interface RS232, RS485
Insulation F
Cooling Forced air, horizontal air intake and upwards exhaust cooling
Transportation With lifting eyes and wheel castors
Color As customer's requirements or as our design
Dimensions About 1250*1550*1680mm L×W×H
Weight About 700kg
Operating Environment Parameter
Ambient Temperature -10°C~+50°C
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa

500kVA Load Bank to Test Generator
500kVA Load Bank to Test Generator500kVA Load Bank to Test Generator

500kVA Load Bank to Test Generator
 