• Variable Resistive Load Bank 50kw Sizing a Load Bank Cabinet Power Testing Bank
  • Variable Resistive Load Bank 50kw Sizing a Load Bank Cabinet Power Testing Bank
  • Variable Resistive Load Bank 50kw Sizing a Load Bank Cabinet Power Testing Bank
  • Variable Resistive Load Bank 50kw Sizing a Load Bank Cabinet Power Testing Bank
  • Variable Resistive Load Bank 50kw Sizing a Load Bank Cabinet Power Testing Bank
  • Variable Resistive Load Bank 50kw Sizing a Load Bank Cabinet Power Testing Bank

Variable Resistive Load Bank 50kw Sizing a Load Bank Cabinet Power Testing Bank

Conditions
of Use:
Land Use
Usage: Common Units
Output Type: AC Three Phase
Cooling
Method:
Oil Cooling
Installation
Method:
Portable
Generator
Type:
Testing Electrical Equipment
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
50kw sizing a load bank
Voltage
400V
Frequency
50Hz
Rated Power
50kw
Insulation Grade
F Class
Cooling
Forced Air Cooling, Horizontal Inlet Air, Upward C
Fan Working Voltage
Internal Wiring 380VAC, 3p4w
Dimension
500*600*700mm
Weight
70kg
Transport Package
Wooden Case
Specification
SGS
Trademark
Triumph Load
Origin
Shijiazhuang, Hebei, China
HS Code
9030339000
Production Capacity
10000sets/Year

Product Description

Variable Resistive Load Bank 50kw sizing a load bank cabinet power testing bank
1. Variable Resistive Load Bank 50kw sizing a load bank cabinet power testing bank
Portable AC Load Bank offers the most robust, high-capacity designs in the industry.   Portable AC Load Bank is setting the standard with intelligent operator controls, safety indication layouts, adjustable load step resolution, and lightweight designs.  Portable AC Load Bank is the perfect solution for regularly scheduled maintenance testing and commissioning of mission-critical standby emergency power systems.
2. AC 400V Variable Resistive Load Bank 50kW Measuring Control Function
Load testing
: Load power that not beyond the rated power, testing and display stable state 3 phases voltage, current, active power, frequency, working time, etc of generator sets.
Load/unload with one key: Whether manual control, remote control or software control, user can preset the power, then press load master button. Load bank loaded according to preset power to avoid load fluctuation during the power changing.
Control Pattern: User can choose local control and intelligent control.
Local Control: There is local control panel with several power steps; user can load/unload by button.
Intelligent Control: Through data processing software in PC, user can make automatic load, to display, record and manage the testing data, to form curves, tables, also to print them.
Control Pattern interlock: There is control pattern switch, when choose one control pattern, operation of other pattern is invalid, avoid the clash.
Local meter display data: local meter can display 3 phases voltage, current, active power, frequency and so on.
Software Function
Communication pattern: 
Intelligent control use photoelectric isolated RS485 interface connect to PC, with great anti-interference performance to make system control stable. Also user can use USB or RS232 through converter.  
Load pattern: Manual Load or Automatic Load.
Manual Load: Input power, system will load according to preset power.
Automatic load: user can preset power and length of working time of several load periods, as per 0%→25%→50%→75%→100% or 110% to make testing.
Parallel testing: when several load bank work in parallel, use can make parallel testing via software, can display, record parameters of every load bank and whole system parameter of parallel operation.
Real-time parameter: through software to display voltage, current, power, power factor, frequency and time, etc.
Security monitoring and control: monitor working state of the load bank by watching software light, when abnormally stop and protect, it can show the reason.
Data collection interval: The minimum data storage interval is 2 seconds.
Data save and query: all the test data is saved in the software, easy to query in the history testing data.
Graphical display: show real-time or history testing data, and support to print curve and graph as follows:
1) Graphs of real-time voltage, current, frequency and power; 2) Voltage graph
3) Current graph; 4) Power graph; 5) Frequency graph; 6) Power factor graph
Data format: all the curves and graphs can be outputted as".doc"format, testing data can be outputted as ".xls" format, and can be printed.
Protection
Emergency stop: 
you can press the Emergency Stop switch in the panel, when the load bank is locked in this state, it cannot add any load.  
Overvoltage protection: when input voltage is over the safe value, it can unload automatically and give an alarm.
Short circuit protection: when short circuit, fuses in the load bank can insure to unload automatically.
Overheating protection: when temperature is over the safe value, it can unload automatically and give an alarm.
Fan interlock protection: load bank cannot add any load when working power of fan is off.
Protection Buttons: There are buttons for some protection, when misinformation occurs or user has special needs, user can temporarily turn off the corresponding protection function.

3. Variable Resistive Load Bank 50kw sizing a load bank cabinet power testing bank

Technical parameter

AC400-50kW

Rated voltage /Frequency

400V/50Hz

Max load power

Resistor load: 50kW

Load step

Resistive load: 5 steps, 1,2,2,5,10,10, 20kW

Power factor

1

Load Tolerance(each step)

±5%

Load Tolerance(overall)

±3%

Display Precision

0.5 class

Control Power Supply

Internal AC380V/50Hz three phase

Wire Connection

Load power supply input--Connector bar (star coupling)

Control power supply input--3core socket

Insulation grade

F class

Duty cycle

Continuous

Cooling

Forced air cooling, Horizontal inlet air, horizontal cooling

Transportation

Hoisting, there are lifting lug in top of casing and casters in bottom of load bank

Casing Color

Grey(RAL7035)

Operating Environment Parameter

Ambient Temperature

-10ºC~+50ºC

Relative Humidity

≤95%

Altitude

≤1500 meters

Atmospheric Pressure

86~106kPa

Main components brand

Contactor

Schneider

Fuse

Delixi

SCM

Infineon

Alloy resistor

Kaixiang

Data management software

Kaixiang

Variable Resistive Load Bank 50kw Sizing a Load Bank Cabinet Power Testing Bank
Variable Resistive Load Bank 50kw Sizing a Load Bank Cabinet Power Testing Bank
 

4. Pictures of AC 400V Variable Resistive Load Bank 50kW


Variable Resistive Load Bank 50kw Sizing a Load Bank Cabinet Power Testing Bank
Variable Resistive Load Bank 50kw Sizing a Load Bank Cabinet Power Testing Bank


5. Why choosing us
The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for       more than 20 years.
The most patent technology and scientific research awards gainer in China.
Advanced detection method and strict inspection procedure build the qualified quality.
Customized production meet the individual requirement.
Prompt delivery & excellent after sales service.
Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.
Contact Information

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now