Rlc Load Bank for Anti-Islanding Inverter Test

Product Details
Customization: Available
Voltage: 480V
R: 33.33kw
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Rlc Load Bank for Anti-Islanding Inverter Test
  • Rlc Load Bank for Anti-Islanding Inverter Test
  • Rlc Load Bank for Anti-Islanding Inverter Test
  • Rlc Load Bank for Anti-Islanding Inverter Test
  • Rlc Load Bank for Anti-Islanding Inverter Test
  • Rlc Load Bank for Anti-Islanding Inverter Test
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
AC480-33KVA
L
33.33kvar
C
33.33kvar
Frequency
50 or 60Hz
PF
0.8
Min Step
1W
Control
PC
Communication
Modbus
Warranty
1year
Transport Package
Wooden Box
Specification
300KGS
Trademark
Triumph Load
Origin
China
HS Code
903039000
Production Capacity
500

Product Description

Product Description

 

Programmable RLC Load Bank, this system include RLC load bank, data acquisition system, automatic load/unload control system, air cooling system, auxiliary control and PC software. It perfectly combines resistance, inductance and capacitance load bank with automatic measurement and control module, which can accurately detect the load capacity and working performance for various photovoltaic power source and inverter power source, effectively test the anti-islanding protection capability of grid-connected inverters, and provide scientific and efficient testing methods for grid-connected inverter power source.
 
Product Parameters

 

Technical Parameters
Rating Voltage AC380V 3 phase 4 wire /60Hz
or AC220V single phase /60Hz
Rating Frequency 60Hz
Wiring Mode 3 phase 4 wire system Y-connection,A,B,C,N four wiring ports
Single phase 2 wire system can be connected to A,N;B,N; C,N one of the three.
Rating Power
AC380V/60Hz
Resistive (R):33.33kW
Inductive(L):33.33kvar
Capacitive(C):33.33kvar
Load Step
AC380V/60Hz
Resistive:Split phase control:0.001,0.002,0.002,0.005,
0.01,0.02,0.02,0.05,0.1,0.2,0.2,0.5,1,2,2,5kW,
Minimum step: 0.001kW.Per phase power:11.11 kW,
three phase total power: 33.33 kW.

Inductive:Split phase control:0.001,0.002,0.002,0.005,
0.01,0.02,0.02,0.05,0.1,0.2,0.2,0.5,1,2,2,5kvar,
Minimum step:0.001kva.Per phase power:11.11kvar
three phase total power:33.33kvar.

Capacitive:Split phase control:0.001,0.002,0.002,0.005,
0.01,0.02,0.02,0.05,0.1,0.2,0.2,0.5,1,2,2,5kvar,
Minimum step:0.001kvar.Per phase power:11.11kvar,
three phase total power:33.33 kvar. 
When input voltage is lower than rated value, gears power changes according to Ohm's law.
Power Factor Adjustment range:±0.3-1, Fully load:±0.7-1
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Voltage Measurement Range 0-300V (phase voltage)
Current Measurement Range 0-100A;
Frequency Measurement Range 45-65Hz
Voltage Accuracy ±0.5%, Resolution :1V
Current Accuracy ±0.25%, Resolution :1A
Power Accuracy ±0.5%,Resolution :0.001 kW
Frequency Accuracy Resolution :0.1Hz
Control Power Supply External AC220V single phase /60Hz,about 2kW
Wire Connection Load Power Supply Input--Busbar
Control power supply input--Terminal block
Communication Interface RS485, RS232
Insulation Class F
Working noise 1 meter away from equipment:≤85dB;
Working Mode Continuous Working
Cooling Forced air cooling,front inlet and backwards outlet
Chassis Structure With lifting eyes and wheel castors and forklift at bottom.
Chassis Color Grey(RAL7035)
Dimension About 900mm*1250mm*1650mm(W*L*H)
Weight About 350kg
Operating Environment Parameter
Work Temperature -10ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤2500M
Atmospheric Pressure 86~106kPa
 
Detailed Photos

 


Rlc Load Bank for Anti-Islanding Inverter Test

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier