  • 500kw Resistive Backup Generator Load Bank
  • 500kw Resistive Backup Generator Load Bank
  • 500kw Resistive Backup Generator Load Bank
  • 500kw Resistive Backup Generator Load Bank
  • 500kw Resistive Backup Generator Load Bank
  • 500kw Resistive Backup Generator Load Bank
Find Similar Products

Basic Info.

Model NO.
AC440-500kW
Working Mode
Continuously
Power Factor
1.0
Certification
ISO CE
Altitude
No More Than 2500 M
Transport Package
Plywood Case
Specification
3 cmb
Trademark
TriumphLoad
Origin
China
HS Code
9030339000
Production Capacity
2000 Sets/ Per Year

Product Description

 500kW Generator  Load Bank 

 

Compact and Lightweight design that is ideal for moving from job site to job site or within your facility.

 

Introduction:

It offers the most robust, high-capacity designs in the industry.  It is setting the standard with intelligent operator controls, safety indication layouts, adjustable load step resolution, and lightweight designs.  It is the perfect solution for regularly scheduled maintenance testing and commissioning of mission-critical standby emergency power systems.

500kw Resistive Backup Generator Load Bank500kw Resistive Backup Generator Load Bank

Main features

1. Multiple control mode: (1) manual panel control (2) remote control (3)software control

2. Multiple display function: voltage, current, frequency, power factor, active power, reactive power, apparent power etc.  

3. Multiple protection function: overvoltage, overcurrent, overheat, over low blowing rate, blower overheat, blower phase sequence reverse protection, smoke alarm etc.

4. Forced air cooling: industrial heavy duty fan, horizon air intake, upwards outlet, low noise.

5. Power consumption components: made by special alloy resistance, high temperature resisting, high heat dissipation capability, high heat stability, no naked light, safety and reliability. Running temperature is 1/3 of rating.

6. Weather-proof structure: containerized structure provides ultra protection, protection grade higher than IP55.

7. Material and coating: the body adopt cold-rolled steel plate that processed by galvanizing corrosion protection, powder coated and spray paint.

8. Integrated & modularization design: compact structure, easy to installation, maintenance and transportation.

9. Software control: it can test and display voltage, current, frequency, power factor, active power, reactive power, apparent power etc, the test result can be store & print and form all kinds of curve, chart and test report.

500kw Resistive Backup Generator Load Bank500kw Resistive Backup Generator Load Bank500kw Resistive Backup Generator Load Bank

Technical Parameters

AC Automatic Load Bank

Rating Voltage/Frequency

440VAC/50Hz, 3 phase 4 wire,  phase voltage 250V

Rated Power

Resistive load: 500kW

Installed Capacity

Resistive load: 500kW

Load Step

1,2,2,5,10,10,20,50,100,100,200,kW, min step load: 1kW

PF(Power Factor)

1

Load Tolerance  (each step)

±5%

Load Tolerance(overall)

±3%

Display Precision

0.5 class

Control Power

380VAC/50Hz 3 phase 4 wire (line voltage 380V, phase voltage 220V )

Wire Connection

Load power supply input--Copper bar (star coupling)

Control power supply input--Connector-bar

Insulation

F

Way of Working

Continuous Working

Casing Dimensions and Cooling

about 1600*2600*2000mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling

Weight

About 1700kgs/set                        

Transportation

Hoisting, there are lifting lug in top of casing and wheel casters in bottom

Casing Color

Grey(RAL7035)or as you required

Operating Environment Parameter

Workplace

Outdoor

Ambient Temperature

-10ºC~+50ºC

Relative Humidity

≤95%

Altitude

≤2500 meter

Atmospheric Pressure

86~106kPa

Brands of Main Components

Contactor

CHINT

Fuse

DELIXI

MCU

INFINEON

Data processing software

Kaixiang(self-developed)

Alloy Resistance

Kaixiang(self-developed)

 

The Main Application Of The Load Bank

Factory testing of engines generator sets

To reduce "wet stacking" problems

Periodic exercising of stand-by engine generator sets

Load testing of AC power source

On-site acceptance testing

UPS system testing and maintenance

New projects inspection and battery system maintenance

Load optimization in prime power applications

Contact us

Hebei Kaixiang Electrical Technology Co., Ltd       
          James Lee
        Sales   Manager
 
No 79 Wangshan Road, Shijiazhuang City, 
Hebei Province, China
 
 
kxload.en.made-in-china.com  

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier