96V 20A DC Load Bank, Programmable DC Electronic Load, UPS Load Bank manufacturer / supplier in China, offering DC240V-100A Load Bank, 200kw Generator Test Load Bank, 5000kVA Load Bank for Generator Test and so on.

Gold Member Since 2014
Audited Supplier

DC240V-100A Load Bank

Get Latest Price
Min. Order / Reference FOB Price
1 Set US $1,000-3,000/ Set
Port: Tianjin, China
Production Capacity: 500 Sets/Year
Payment Terms: L/C, T/T, Western Union
Type: Storage Battery Tester
Test Region: All
Application: Ordinary Battery
Customized: Non-Customized
Voltage: 240VDC
Discharge Current: 1-100A

You Might Also Like


Basic Info

Model NO.: DC240V-100A
Contactor: 240V
Applicable Battery: 1.2V 2V 4V 6V 12V
Control Precision: 0.1 V 0.1A
Nominal Voltage: 240V
Trademark: Triumph Load
Transport Package: Wooden Boxes, or as Required
Origin: China
HS Code: 90303390

Product Description

DC240V-100A Load Bank
Voltage: 240V, Max current 100A.

1. DC Load Bank is the instrument that can maintain and test capacity of battery, DC power and UPS backup battery. Battery and DC capability can be seen clearly.
2. Supply List
The following form presents the accessories provided when we make shipment.
DC240-100 Automatic Load Bank1 
Power Cord13 meter
Operation Manual2 
Warranty Card112 months
Packing List1 
Receiving Apron1 
Test Report1 
3. Main features and functions:
1). Display: LED display all parameters and test data in real-time with English menu. Display testing data: voltage, current, capacity, discharging time, temperature, etc.
2). Automatic stop: It can stop testing automatically meet following conditions: test time out, testing capacity out and protective voltage out.
3). Protection: Perfect automatic protection and alarm function: When high temperature, opposing connection, automatic protection power-off and sending alarm sound.
4). Real-time monitor function: display real-time all setting parameter (for example voltage, current and time, etc.)
5). Discharger can correct the displayed voltage and current, especially the group voltage and current.
6). Power-consuming is special alloy resistor with small temperature drift, patent technology design, high power density, and safe.
4. Technical Parameters Sheet
Battery Nominal Voltage240VDC
Discharging Voltage80-300V can discharge. Voltage 240V±10% reach the highest current 100A, can discharge for long time
Protective Voltage0-300V
Discharging Current0 -100A
Discharging Time1 minute-99 hours and 59 minutes
Discharging Capacity1-9999Ah
Group Voltage Tolerance±1%
Current Tolerance±1%
Constant-current Discharge Control Tolerance ±(0.3%+0.2A)
Power Supply220VAC 50Hz Single phase
CoolingForced air cooling
Environment temperature-10ºC - +40ºC
Volume(mm)About 480*330*572 (width*depth*height)