11kv 4MW Generator Test Load Bank

Product Details
Customization: Available
Conditions
of Use:
Trailer Type, Marine, Land Use
Usage: Standby Unit, Common Units
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • 11kv 4MW Generator Test Load Bank
  • 11kv 4MW Generator Test Load Bank
  • 11kv 4MW Generator Test Load Bank
  • 11kv 4MW Generator Test Load Bank
  • 11kv 4MW Generator Test Load Bank
  • 11kv 4MW Generator Test Load Bank
Find Similar Products

Basic Info.

Model NO.
AC11-4000KW
Output Type
AC Three Phase
Cooling
Method
Air Cooled
Installation
Method
Fixed
Generator
Type
Diesel Generator
Voltage
11kv
Power
4000kw
Frequency
50Hz, 60Hz
PF
1
IP
54
Cooling
Air Cooled
Resistor
Metal Alloy
Control
Local and Remote
Warranty
12months
Transport Package
Container
Specification
ISO
Trademark
Triumph Load
Origin
China
HS Code
90303900
Production Capacity
400units

Product Description

11KV 4000kW  Load Bank for Gas Turbine Testing:

The ability to test critical power systems at voltages of 1.2KV to 80kV using direct-connect, High Voltage Load Bank offers engineers flexibility, time savings, cost savings, space savings and simplicity. It mainly used to commission utility, oil & gas, and industrial power systems without the need for additional transformers and cabling.

Application of 11KV 4000kW  Load Bank for Gas Turbine Testing:

Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
11kv 4MW Generator Test Load Bank11kv 4MW Generator Test Load Bank11kv 4MW Generator Test Load Bank
11kv 4MW Generator Test Load Bank
 

System Parameter

Rating voltage/frequency

11KV, 3 phase 3wire 50Hz

Max Load Power

 Resistive Load: 4000kW

Load Steps

Total 6 steps:500kw,500kw,500kw,500kw,1000kw,1000kw

Power Factor

1

Load Tolerance (each step)

±5%

Load Tolerance (overall)

±3%

Fan &Control Voltage

External AC 3 phase 4 line, 380V/50Hz

Wire Connection

Load bank input--Copper bar (star coupling "Y")

Control power input--Connector-bar

Communication Interface

RS485,RS232

Insulation

F

Max Protection Grade

IP54

Duty Cycle

Continuous  

Cooling

Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling

Enclosure

Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door

Internal Lighting

Adequate internal lighting will be provided

Transportation

Hoisting, there are lifting lug in top of casing

Color

Grey RAL7035 or as required

Dimensions

About 9150mm×2350mm×2591mm(L×W×H)

Operating Environment Parameter

Ambient Temperature

-10ºC~+50ºC

Relative Humidity

≤95%

Atmospheric Pressure

86~106kPa

 