• 2000kVA Resistive Reactive Load Bank for Generator Testing
  • 2000kVA Resistive Reactive Load Bank for Generator Testing
  • 2000kVA Resistive Reactive Load Bank for Generator Testing
  • 2000kVA Resistive Reactive Load Bank for Generator Testing
  • 2000kVA Resistive Reactive Load Bank for Generator Testing
  • 2000kVA Resistive Reactive Load Bank for Generator Testing

2000kVA Resistive Reactive Load Bank for Generator Testing

Type: Self-Starting Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Air Cooled
Output Type: AC Three Phase
Speed: Speed
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
2000KVA-RL
Conditions of Use
Marine
Usage
Standby Unit
Landuse Type of Unit
Automation Type
Excitation Mode
AC Rotating Exciter
Name
2000kVA Resistive Reactive Load Bank for Generator
Atmospheric Pressure
86~106kpa
Insulation Grade
F
Load Tolerance(Each Step)
±5%
Load Tolerance(Overall)
±3%
Display Precision
0.5 Class
Ambient Temperature
-10°c~+50°c (14°f~122°f)
Communication Interface
RS-485, RS-232
Duty Cycle
Continuous
Cooling
Forced Air Cooling
Transport Package
Container Type
Specification
ISO9001: 2008
Trademark
Triumph load
Origin
Hebei, China
HS Code
90303390
Production Capacity
110units/Year

Product Description

The RL Series Resistive-Reactive Load Banks offers a 0.80 power factor load and is designed for testing large generators, switchgear, transformers and UPS systems. The structural skid with fork lift pockets allows for portability and is ideal for shipyards, power plants, OEMs and data centers. The RL Series is the perfect solution for regularly scheduled maintenance testing and commissioning of mission-critical standby emergency power systems where rated kVA, rated power factor and rated current testing is required.
Application
Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
 

Rating Voltage/Frequency

AC 400V,50Hz

Compatible voltage

Resistive Load: 1600kW, Inductive load: 1200KVAR

Load Step

Resistive Load:
1   pcs Selector Switch :0.5-5kW,
18 pcs Button   Switch :
5, 10, 10, 10, 20, 20, 20, 50, 50, 100, 100, 100, 100, 200, 200, 200, 200, 200kW;

Inductive Load:
1   pcs Selector Switch :0.5-5kVAR,
15 pcs Button   Switch :
5, 10, 10, 10, 20, 20, 20, 50, 50, 100, 100, 200, 200, 200, 200kVAR;

Power Factor

0.8

Load Tolerance(each step)

±5%

Load Tolerance(overall)

±3%

Display Precision

0.5 class

Control Power Supply

AC380V/50Hz Three Phase  Four Wire

Wire Connection

Three-phase four-wire

Communication Interface

RS-485, RS-232

Duty Cycle
Continuous

Cooling

Forced air cooling, Vertical airflow, Horizontal inlet air, Upward cooling

Dimension

About  6058mmx2438mmx2591mm(Length *Width*Height)

Weight

About 13000kgs

Ambient Temperature

-10ºC~+50ºC  (14°F~122°F)

Relative Humidity

≤95%

Altitude

≤2500 meters

Atmospheric Pressure

86~106kPa

 2000kVA Resistive Reactive Load Bank for Generator Testing

2000kVA Resistive Reactive Load Bank for Generator Testing
2000kVA Resistive Reactive Load Bank for Generator Testing
2000kVA Resistive Reactive Load Bank for Generator Testing
2000kVA Resistive Reactive Load Bank for Generator Testing

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now