AC13.8kv/6.6kv-2500kw High Voltage Load Bank for Generator, Power Plant Testing

Product Details
Customization: Available
Conditions
of Use:
Land Use
Usage: Common Units
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • AC13.8kv/6.6kv-2500kw High Voltage Load Bank for Generator, Power Plant Testing
  • AC13.8kv/6.6kv-2500kw High Voltage Load Bank for Generator, Power Plant Testing
  • AC13.8kv/6.6kv-2500kw High Voltage Load Bank for Generator, Power Plant Testing
  • AC13.8kv/6.6kv-2500kw High Voltage Load Bank for Generator, Power Plant Testing
  • AC13.8kv/6.6kv-2500kw High Voltage Load Bank for Generator, Power Plant Testing
  • AC13.8kv/6.6kv-2500kw High Voltage Load Bank for Generator, Power Plant Testing
Find Similar Products

Basic Info.

Model NO.
AC13.8kv/6.6kv-2500kW
Output Type
AC Three Phase
Cooling
Method
Air Cooled
Installation
Method
Container
Generator
Type
for Generator Set
Voltage
AC13.8kv/6.6kv
Frequency
50Hz/60Hz
Resistive Load
2500kw
Insulation Grade
F Class
Transport Package
Container
Specification
2500KW
Trademark
triumph load
Origin
China
HS Code
9030339000
Production Capacity
10000set/Year

Product Description

AC13.8kv/6.6kv-2500kW high voltage Load Bank for Generator, power plant Testing
Feature:
Medium voltage load banks
1.Voltages up to 33kv
2.50-60Hz
3.Resistive & resistive-reactive
4.20,40ft conainer sizes
5.1000kva-6000kva
6.IP55 standard protection
7.Multiple 1kva/1kw load steps
8.stainless steel finned elements
9.Choice of control system for all units-suited to application&operators
1.Product Introduction

Load bank consists of 1 sets of 2.5MW load bank. The system is made up of two parts of measurement & control and load, mainly
including the high voltage dry type AC load bank, automatic data acquisition system, automatically loading and unloading control
system, the cooling device, auxiliary control, remote control box and PC software and so on.
AC13.8kv/6.6kv-2500kw High Voltage Load Bank for Generator, Power Plant TestingAC13.8kv/6.6kv-2500kw High Voltage Load Bank for Generator, Power Plant Testing

2.Adjustable AC Load Bank Generator Set Intelligent Testing System Working Environment
Altitute:≤2500m
Temperature:-20°C~50°C
Humidity:≤95%RH
Working Mode:Continuous work(>6hours continuous long-term work per day)
3.Adjustable AC Load Bank Generator Set Intelligent Testing System Technical Specifications
System Parameter 
Rating voltage/frequency AC13.8KV/6.6KV, 3 phase 3wire, 60Hz
Max Load Power 13.8KV Resistive Load: 2500kW
6.6KV Resistive Load: 2500kW
(We added extra two high voltage contactors for the star-angle conversion and both voltage can be to 2500kw,you can choose it through control panel or software) 
Load Steps Resistive Load: 6steps,
100/200/200/500/500/1000 
Power Factor 1
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External AC 400V, 3 phase 4wire, 60Hz
Wire Connection  Load bank input--Copper bar 
Control power input--Connector-bar
Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP54
Duty Cycle Continuous  
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions About 9150mm*2350mm*2591mm(L×W×H)
Operating Environment Parameter
Ambient Temperature -20ºC~+50ºC
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
PLC Siemens
Fuse Chuantai
Alloy Resistor (self-developing)
Data Processing Software  (self-developing)

 AC13.8kv/6.6kv-2500kw High Voltage Load Bank for Generator, Power Plant Testing
AC13.8kv/6.6kv-2500kw High Voltage Load Bank for Generator, Power Plant TestingAC13.8kv/6.6kv-2500kw High Voltage Load Bank for Generator, Power Plant Testing


4.Why choosing us

The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
The most patent technology and scientific research awards gainer in China.
Advanced detection method and strict inspection procedure build the qualified quality.
Customized production meet the individual requirement.
Prompt delivery & excellent after sales service.
Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.
 

 