500kw Outdoor Load Bank for Generator Testing

Rated Voltage: 415VAC 3phase 4wire 50Hz
Rated Power: 500kw
PF: 1
Duty Cycle: Continuous
Cooling: Forced Air Cooling
Hot Air: Vertical
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC400-500kW
Dimension
1800mm*1300*1070mm
Trademark
Triumph Load
Origin
China
HS Code
9030339000
Production Capacity
10set/Month

Product Description

Load bank testing solutions include load banks that test the operation of an electrical system. Load banks control the total load, power factor and schedule during the test. Many of the devices in an electrical system use sensors that measure current to determine their function. Electrical load needs to be added during a system test to ensure all sensors have adequate current to perform as intended.

 

There are three main load bank testing solutions:  Resistive, Reactive and Resistive/Reactive:

 

Resistive Load Banks - The most common type, resistive load banks mimic the operational load that a power source will see in actual use. They convert electrical energy to heat using power resistors and dissipate the heat using air or water.

 

Reactive Load Banks - These solutions are used to simulate systems affected by electric motors or other electromagnetic devices on a power network. Typically, equipment that requires reactive power compensation are motor-driven devices, transformers and capacitors. Reactive Load banks can simulate either an inductive or capacitive load depending on the type of load expected on the power system

Resistive/Reactive Load Banks - These solutions combine both resistive and reactive elements in one load bank package. They may accommodate equipment up to 6250 kW. These load banks can also be used for integrated system testing of utility substation protection systems, particularly for more complex relays like distance, directional overcurrent, power directional and others.

AC415-500kW Automatic Load Bank
Rating Voltage/Frequency 415VAC, 3 phase 4wire 50HZ
Rated Load Power 500kW
Load Step 1,2,2,5,10,10,20,50,100,100,200kW, min step load: 1kW
PF(Power Factor) 1
Load Tolerance  (each step) ±5%
Load Tolerance(overall) ±3%
Display Precision 0.5 class
Fan & Control Power External 415VAC, 3 phase 4wire 50HZ  
Wire Connection Load power supply input--Copper bar (star coupling)
Control power supply input--Connector-bar
Insulation F
Duty Cycle Continuous  
Cooling Type Force air cooling, horizontal air inlet & air outlet, with louver and protection door
Transportation Hoisting, there are lifting lug on top
Protection IP55
Dimension About 1800mm*1300*1070mm(L×W×H)
Weight About 700kgs
Enclosure Color  As required
Operating Environment Parameter
Workplace Outdoor
Ambient Temperature -20ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤2500 meter
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Imported brand
Fuse Miro
PLC Siemens
Data processing software Kaixiang(self-developed)
Alloy Resistance Kaixiang(self-developed)
500kw Outdoor Load Bank for Generator Testing
500kw Outdoor Load Bank for Generator Testing
500kw Outdoor Load Bank for Generator Testing
500kw Outdoor Load Bank for Generator Testing
500kw Outdoor Load Bank for Generator Testing
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now