200kw 3phase Resistive Load Bank for Data Center

Rated Voltage: 415/240V
Rated Power: 200kw
Power Factor: 1
Duty Cycle: Continuous
Cooling: Forced Air Cooling
Transportation: with Lifting Lug on Top and Castor
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Dimension
1200mm*850mm*1600mm
Ambient Temp
Ature: -10ºC~+50ºC
Trademark
Triumph Load
Origin
China
HS Code
9030339000
Production Capacity
25units/Month

Product Description

KX provide lot of load banks to data center in global every year. Which widely used in projects of Amazon, Equinix, Huawei, Alibaba, Tecent etc. KX customization production all kinds of load banks, such as Resistive Load Bank, Resistive Inductive Load Bank, High Voltage Load Bank, Rack Mount Load Bank. The dimension, power, voltage, function, cooling type, communication mode, control mode etc could be design according to requirement of each project.
Compact and Lightweight design that is ideal for moving from job site to job site or within your facility.
Portable Indoor Load Banks offers the most robust, high-capacity designs in the industry.  It is setting the standard with intelligent operator controls, safety indication layouts, adjustable load step resolution, and lightweight designs.  It is the perfect solution for regularly scheduled maintenance testing and commissioning of mission-critical standby emergency power systems.

 

Main features and advantages  

1.    Power consumption components adopt special alloy resistor, high-temperature resisting, small thermal drift, safe and reliable. Running temperature is 1/3 of design temperature.

2.    Industrial heavy duty blower, horizontal inlet, vertical exhaust, low noise.

3.    Weather-proof structure, suitable for abominable environment.

4.    Multiple control mode: (1)Local panel control, (2)Remote control box/cabinet(3) Intelligent control(by PC software)

5.    Multiple protection function: overvoltage, overcurrent, overheat, low over blowing rate, blower overheat, blower phase sequence reverse protection, smoke alarm etc.

6.    Integrated design, easy to installation.

Technical Parameter  

Technical Parameter
Rating Voltage/Frequency 415VAC, 3 phase 4wire, 50Hz/60Hz
Rated Load Power Resistive load: 200kW
Load Step
(AC400V/50Hz)
Resistive load: 9 steps
1kW, 2kW, 2kW, 5kW, 10kW, 10kW, 20kW, 50kW, 100kW
PF(Power Factor) 1
Load Tolerance  (each step) ±5%
Load Tolerance(overall) ±3%
Display Precision 0.5 class
Control Mode Manual
Control Power External 230VAC/50Hz, 1phase, 4kVA
Wire Connection Load power supply input--Copper bar (star coupling)
Control power supply input--Connector-bar.
Insulation F
Duty Cycle Continuous  
Cooling Type Force air cooling, horizontal air inlet and vertical air outlet
Transportation Hoisting, there are lifting lug on top and white castor wheel at the bottom of casing
Color Grey RAL7035 or as required
Dimension About 1200mm*850mm*1600mm(L×W×H)
Weight About 550kgs
Operating Environment Parameter
Ambient Temperature -20ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤2500 meter
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Schneider
Fuse Miro
Alloy Resistance Kaixiang(self-developed)
200kw 3phase Resistive Load Bank for Data Center
200kw 3phase Resistive Load Bank for Data Center200kw 3phase Resistive Load Bank for Data Center200kw 3phase Resistive Load Bank for Data Center





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now