• Lb-24/135/270/480-750 Constant Current DC Dummy Load Bank
  • Lb-24/135/270/480-750 Constant Current DC Dummy Load Bank
  • Lb-24/135/270/480-750 Constant Current DC Dummy Load Bank
  • Lb-24/135/270/480-750 Constant Current DC Dummy Load Bank
  • Lb-24/135/270/480-750 Constant Current DC Dummy Load Bank
  • Lb-24/135/270/480-750 Constant Current DC Dummy Load Bank

Lb-24/135/270/480-750 Constant Current DC Dummy Load Bank

After-sales Service: 12 Months
Rating Voltage/Frequency: 3 Phase 4 Wire AC200V/400Hz, Phase Voltage 115V
Load Installed Power: Resistive Load: 50.22kw
Power Factor: 1
Control Power Supply: External Connection Single Phase AC220V/50Hz/Appro
Cooling: Forced Air Cooling, Horizontal Air Inlet, Wind out
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
LB-24/135/270/480-750
Transport Package
Wooden Case
Trademark
Triumph Load
Origin
Hebei, China (Mainland)
HS Code
9030339000
Production Capacity
500 Set/Sets Per Year

Product Description

Multi-circuit AC/DC Load Bank
Technical Parameters 
 
Rating Voltage/Frequency 3 phase 4 wire AC200V/400Hz, phase voltage 115V
Load installed power Resistive load: 50.22kW
Load Step Resistive load: there are 5 independent three-phase four-wire circuits
Circuit 1: 15A, 2 steps5A, 10A;
Circuit 2: 15A, 2 steps5A, 10A;
Circuit 3: 15A, 2 steps5A, 10A;
Circuit 4: 50A, 4 steps5A, 10A,15A, 20A;
Circuit 5: 50A, 4 steps5A, 10A, 15A, 20A.
Power Facto 1
Load Tolerance(each step) ±5%
Load Tolerance(overall) ±3%
Display Precision 0.5 class
Control Power Supply External connection single phase AC220V/50Hz/approximately 3kW
Wire Connection Load power supply input--5 binding post (Star connection), center line of each load is individually derived and then connected in parallel
Control power supply input--line bank 
Insulation Class F
Working Mode Continuous 
Cooling Forced air cooling, horizontal air inlet, wind outlet from back.
Transportation There are four casters on the bottom of load bank
Chassis color (RAL7035)
Size Approximately 1250*900*1630mm (Width *Depth *Height)
Weight 100kg
 
Rating Voltage DC 28V
Load installed power Resistive load: 5.6kW
Load Step Resistive load: There are four independent circuits
Circuit 1: 50A, 4 steps5A, 10A, 15A, 20A;
Circuit 2: 50A, 4 steps5A, 10A, 15A, 20A;
Circuit 3: 50A, 4 steps5A, 10A, 15A, 20A;
Circuit 4: 50A, 4 steps5A, 10A, 15A, 20A.

Load Tolerance(each step)
±5%

Load Tolerance(overall)
±3%

Display Precision

0.5 class

Wire Connection

Load power supply input--binding post, The negative pole is elicitation separately and then connected in paralle
Chassis structure .
Installed in one cabinet with AC load 

Working Environment  
Working place
Indoor

Ambient Temperature
-10ºC~+50ºC

Relative Humidity
≤95%

Altitude
≤1500 meters

Atmospheric Pressure
86~106kPa

Measuring Control Function

(1)Load control: Load any current value within the rated value, measure and display the voltage and current parameters of each circuit.
(2)Manual control: The load is equipped with a local control panel and is divided into several power gears that can be loaded by switch control. 
(3)Control pattern interlock: There is control pattern switch, when choose one control pattern, operation of the other pattern is invalid, avoid the clash.

Protection

(1)Emergency stop: User can press Emergency Stop switch in panel, when the load bank is locked in this state, it can't add any load. 
(2)Overvoltage protection: When input voltage is over the safety value, it will unload automatically and give an alarm.
(3)Short circuit protection: Fuse could avoids damage to equipment when short circuit or current overload.
(4)Overheating protection: When temperature is over the safety threshold, it will unload automatically and give an alarm.
(5)Fan interlock protection: Load bank can't add any load before working power on.
(6)Protection Buttons: There are buttons for some protection, when misinformation occurs or user has special needs, user can temporarily turn off the corresponding protection function.
(7)Chassis Ground Protection: in order to avoid the danger of electric shock when operating, the load bank is equipped with special ground protection termi
Thanks for use Multi-circuit AC/DC Load Bank. According to the special requirements of the user's use site, this agreement proposes the technical standards of the functions, performance, usage, structure, installation and test of Multi-circuit AC/DC Load Bank (hereinafter referred to as load bank), which is an efficient and reliable choice for client to meet the needs of the generator set. The load bank consists of two parts: AC load and DC load. It mainly includes dry AC load, dry DC load, data acquisition system, control part, heat sink and auxiliary control.

Lb-24/135/270/480-750 Constant Current DC Dummy Load Bank
Lb-24/135/270/480-750 Constant Current DC Dummy Load Bank

Contact Information

Kaixiang Electrical Technology Co., LTD.
Eric Zhang
ADD:79Wangshan Rd,Luquan District,Shijiazhuang,Hebei,050221,P.R.China
 
 
M.T.:+86 18937738282
Our service is beyond of products,but the feeling of customers

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now