• AC415 2000kw Dummy Load Bank for Genset
  • AC415 2000kw Dummy Load Bank for Genset
  • AC415 2000kw Dummy Load Bank for Genset
  • AC415 2000kw Dummy Load Bank for Genset
  • AC415 2000kw Dummy Load Bank for Genset
  • AC415 2000kw Dummy Load Bank for Genset

AC415 2000kw Dummy Load Bank for Genset

After-sales Service: 12 Months
Warranty: 12 Months
Type: Electrical Performance Testing
Maxcapacity: >1000KN
Accuracy Grade: 0.5
Load Way: Electronic Load
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC415-2000kW
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
>2000Kg
Power Source
AC380V
Oil Cylinder Position
No
Capacity
2000kw
Useage
Outdoor
Color
Ral7067
Cooling
Forced Air Cooling
Transport Package
Container
Specification
20 container
Trademark
TrumphLoad
Origin
China
HS Code
9030300900
Production Capacity
200 Sets Per Year

Product Description



AC 415V 2500KVA Resistive Inductive Dummy Load Bank
1.Product Introduction
AC415-2500KVA Resistive Inductive Dummy Load Bank
This machine is mainly used for the national grid, research institutes, national defense, electricity, telecommunications, railways, instrumentation, universities and other areas of diesel generator sets, power online UPS, inverters, switching power performance testing, aging and other occasions. This machine has a variety of control methods, either stand-alone operation, but also with the same series of load and machine. Optimized for power input segmented to adapt to different loads and different power factor requirements.
AC415 2000kw Dummy Load Bank for GensetAC415 2000kw Dummy Load Bank for Genset
2.AC415-4445KVA Resistive Inductive Dummy Load Bank Working Environment
Altitute:≤2500m
Temperature:-10°C~50°C
Humidity:≤95%RH
Working Mode:Continuous work(>6hours continuous long-term work per day)
 
3. AC415-4445KVA Resistive Inductive Dummy Load Bank Technical  Specifications 
 

Load a single set of system parameters

Rated voltage 
and frequency

AC three-phase four-wire 690V, 50Hz / 60Hz
AC three-phase three-wire 400V, 50Hz / 60Hz

Load rated power

Resistive load: 200 0kW, inductive load: 1939kvar, apparent power: 1800kVA
(When the input voltage is below the rated voltage, load the actual power by 
Ohm's law descending)

Maximum load power

690V/ 400V, when 50Hz, resistive load: 4010 kW, inductive load: 2410kvar

Load Binning

In 690V/400V, 60Hz calibration sub-file, sub-file as follows:
Resistive Load: point 28 stalls, 1, 2, 2, 5, 10, 20, 20, 50, 100,200 × 19 (Unit: kW)
Inductive load: min 21 files, 0 5, 1, 2, 2, 5, 10, 20, 20, 50, 100, 200 × 11. (Unit: kvar)
Other voltage and frequency corresponding to the power of the power See table 5.6

Power Factor

0.9 (0.1 ~ 1 adjustable)

Load accuracy (per file)

± 5%

Load accuracy (whole)

± 3%

Display accuracy

0.5

Control Power

External AC three-phase four-wire 380V/50Hz, 50kW

Wiring

Load Power Input - copper (Manual Star - Delta Connection conversion)
Control power input - terminal block

Wiring port design

Allow sufficient space to ensure that users can easily access the load cables.
External load penetrating openings in the cables after the cables have sufficient 
waterproof capability, and sufficient mechanical strength.

Communication Interface

RS485, RS232

And machine methods

Computer software and machine

Insulation class

Class F

Protection class

IP56 (save state)

Noise

3 m away from the outlet is less than 9 0 db

Work

Continuous work

Cooling

Forced air, side air intake on the wind

Chassis construction

Container package, with up to the top of the ladder, with inlet and outlet 
grilles and door protection

Transport

There bearing hanging hole, in line with lifting and transport conditions.

Chassis Size

Approximately 9000mm × 2 500 mm × 2 900mm (L × W × H)

Weight

Approximately 20 000kg

Work environment parameters

Workplace

Coastal areas, outdoor work

Operating Temperature

- 25 ºC ~ + 6 0 ºC (lower limit of the instrument's temperature-10 ºC)

Relative Humidity

≤ 95%

Altitude

≤ 2500m

Atmospheric pressure

86 ~ 106kPa
 


4.Why choosing us
The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
The most patent technology and scientific research awards gainer in China.
Advanced detection method and strict inspection procedure build the qualified quality.
Customized production meet the individual requirement.
Prompt delivery & excellent after sales service.
Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.
AC415 2000kw Dummy Load Bank for GensetAC415 2000kw Dummy Load Bank for GensetAC415 2000kw Dummy Load Bank for Genset

5 Contact Information


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now