415V 3500kVA Resistive Reactive Load Bank

Product Details
Customization: Available
Apparent Power: 3500kVA
Resistive Power: 2800kw
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • 415V 3500kVA Resistive Reactive Load Bank
  • 415V 3500kVA Resistive Reactive Load Bank
  • 415V 3500kVA Resistive Reactive Load Bank
  • 415V 3500kVA Resistive Reactive Load Bank
  • 415V 3500kVA Resistive Reactive Load Bank
  • 415V 3500kVA Resistive Reactive Load Bank
Find Similar Products

Basic Info.

Model NO.
AC415-3500KVA
Inductive Power
2100kvar
Power Factor
0.8
Rated Voltage
415VAC, 3phase, 50Hz
Protection
IP55
Enclosure
Weatherproof
Dimension
6058*2438*2591mm
Contactor
Schneider
Display Precision
0.5 Grade
Transport Package
Inner: Plastic Film, Outer: Wooden Case
Specification
ISO9001: 2008
Trademark
Triumph Load
Origin
Hebei, China
HS Code
90303900
Production Capacity
20sets/Month

Product Description

Technical Parameters

 
System Parameter
Rating voltage/frequency 415V, 3 phase 4 wire 50Hz
Max Load Power Apparent Power: 3500KVA
Resistive Load: 2800kW
Inductive Load: 2100KVAR
Load Resolution Resistive Load: 22 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW 
Inductive Load: 19 steps 
1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR, 100KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR,200KVAR,200KVAR,200KVAR,200KVAR,200KVAR
Power Factor 0.8(lag)
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External AC 3 phase 4 wire, 415V/50Hz 
Wire Connection Load bank input--Copper bar (star coupling "Y")
Control power input--Connector-bar
Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP55
Duty Cycle Continuous  
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions About 6058mm×2438mm×2591mm(L×W×H)
Operating Environment Parameter
Workplace  Outdoor 
Ambient Temperature -10ºC~+50ºC
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor   Schneider
Fuse  Miro
PLC  Siemens
Alloy Resistor   Kaixiang
Data Processing Software  Kaixiang
 

Test Function

(1) Steady-state test: can be loaded within the appropriate power rating, measure and display generators steady phase voltage, current, active power, reactive power, apparent power, power factor, frequency, running time and other parameters.

(2) One-key load/unload: Whether load/unload by local control panel or by PC software control, user can pre-set the power then press the master load button.

(3) Control mode: user can choose local control, remote control or intelligent control (PC control)

(4) Local manual control: there is local control panel in load bank, with multi load steps, min load steps 1kW, controlled by buttons.

(5)  Remote control: With remote controller box connected to load bank by control cable.

(6) Intelligent control: user can control load bank by data processing software of PC to make automatic load/unload, display, record and manager the test data, form curve, graph and can be printed.

(7) Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.

(8) Local meter display data: 3 phase voltage, current, active power, reactive power, apparent power, power factor, frequency etc.

Protection

(1) Emergency stop: User can press the emergency stop button in the panel to unload immediately when the load bank is abnormal while working.

(2) Over-voltage protection: Automatic load dump and give alarm when voltage is over safety thresholds.

(3) Short Circuit Protection: Fuse could avoids damage to equipment when short circuit or current overload.

(4) Over-heat protection: Automatic load dump and give alarm when temperature is over safety thresholds.

(5) Smoke Fog Protection: If there is smoke fog in the container, system unload automatically and give an alarm.

(6) Fan interlock protection: Machine could not do load testing before working power of fan is on.

(7) Fan air volume protection: When fan air volume Insufficient, auto unload and send a alarm.

(8) Fan phase sequence auto transfer protection: when control power is not connect with correct order, 3 phase fan also can operate normally.

(9) Protection switch: there are some protection buttons can be switched off when false alarm or for special requirements.

 415V 3500kVA Resistive Reactive Load Bank
415V 3500kVA Resistive Reactive Load Bank
415V 3500kVA Resistive Reactive Load Bank
415V 3500kVA Resistive Reactive Load Bank
415V 3500kVA Resistive Reactive Load Bank


415V 3500kVA Resistive Reactive Load Bank
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier