First Class Load Bank 2000kw ac load banks with ISO Ce Certificate
1.Product Introduction
6.6KV Generator Resistive Load Bank 2000KW Triumph Load
High voltage load bank,the optional voltage range is 6.6KV~35KV,can be directly used for large high
voltage generator, need not to be equipped with conventional step down transformer.
We can also provide regular load bank for high voltage equipment,need to use step-down transformer together.
2. 6.6KV Generator Resistive Load Bank 2000KW Triumph Load Application
Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current
protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
3. 6.6KV Generator Resistive Load Bank 2000KW Triumph Load Working EnvironmentAltitute:≤1500m
Temperature:-10°C~50°C
Humidity:≤95%RH
Working Mode:Continuous work(>6hours continuous long-term work per day)
4. 6.6KV Generator Resistive Load Bank 2000KW Triumph Load Technical Specifications
System Parameters (Single set) |
|
Rated Voltage/ Frequency |
AC6.6KV/50Hz, 3 phases 4 wire
|
Installer Capacity |
2000KW |
Step Load |
400KW,400KW,800KW, 3 steps |
Power Factor (PF) |
1 |
Load Tolerance |
5% |
Display Precision |
0.5 grade |
Control Power Supply |
AC380V/50Hz, 3 phases 4 wire |
Insulation |
F |
Max Protection Grade |
IP54 |
Working Mode |
Continuous |
Cooling |
Forced air cooling, Horizontal inlet air, Vertical cooling |
Casing Structure |
Standard 20 feet container, with a ladder to top |
Transportation |
Hoisting, there are lifting lugs in top of casing |
Dimension |
4000mm×2438 mm×2896mm |
Weight |
About 15000kg |
Working Environment Parameters |
|
Ambient Temperature |
-20ºC~+55ºC |
Relative Humidity |
≤95% |
Altitude |
≤2500 meters |
Atmospheric Pressure |
86~106kPa |
Working Temperature |
Temperature inside container: less than 35ºC,forced-air cooling |
Functions
User could load any power within rated power, can test stable state three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency, running time of generating set.
Whether load/unload by local control panel or by PC software control, user can pre-set the power then press the master load button.
Control mode: user can choose local control or intelligent control (PC control).
Local manual control: there is local control panel in load bank, with multi load steps, min load steps 1kW, controlled by buttons.
Intelligent control: user can control load bank by data processing software of PC to make automatic load/unload, display, record and manager the test data, form curve, graph and can be printed.
Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.
With data processing software, could form curve of current, active power, reactive power, apparent power, power factor, frequency and can be printed.
One-key load/unload: user can load or unload with one key easy to control.
3 line LED multi-function meter display.
Data Processing Software Functions
Communication type: through RS232, RS485 or USB interface.
Load mode: manual load or automatic load.
Manual load: input power and power factor.
Automatic load: User can set several periods of power and time, and in turn of 0%→25%→50%→75%→100%, etc or other preset order to make automatic load testing.
Parallel testing: when several load banks parallel working, parameters of each load bank can be displayed and recorded, so do the final parameters of paralleling working.
Real-time parameter: Current, voltage, power, power factor, frequency, time, etc could be displayed by software.
Safety monitoring: User can know the working conditions of load bank through software indicating light. When in abnormal stop protection, software will indicate the reasons of stopping.
Data collection interval: the min saving interval is 2 seconds.
Data saving and in query: testing data could be saved in software, user can query at any time.
Data display: it could display real-time data and history data; user can print voltage, current, frequency, power graphs and charts.
Charts and graphs are output in format of JPG while testing data output in Excel format, and all can be printed.
Protection
(1) User can press the emergency stop button in the panel to unload immediately when the load bank is abnormal while working.
(2) Over-load: Automatic load dump and give alarm when voltage is over safety thresholds.
(3) Over-heat protection: Automatic load dump and give alarm when temperature is over safety thresholds.
(4) Short Circuit Protection: Fuse could avoids damage to equipment when short circuit or current overload.
(5) Fan protection: Machine could not do load testing before working power of fan is on.
(6) The machine will unload and give alarm when any fan is abnormal or with insufficient air volume, etc.
(7) When control power cable in wrong connections, 3 phase fans can also work in good conditions.
(8) Protection button: there are some protection buttons can be switched off when false alarm or for special requirements.