Measuring Control Function
--Load testing: load power that not beyond the rated power, testing and display stable state 3 phases voltage, current, active power, frequency, working time, etc of generator sets.
--Load/unload with one key: Whether manual control, remote control or software control, user can preset the power, then press load master button. Load bank loaded according to preset power to avoid load fluctuation during the power changing.
--Control Pattern: user can choose local control, remote control and intelligent control.
--Local Control: There is local control panel with several power steps; user can load/unload by button.
--Remote Control: Control through remote control box.
--Intelligent Control: Through data processing software in PC, user can make automatic load, to display, record and manage the testing data, to form curves, tables, also to print them.
--Control Pattern interlock, there is control pattern switch, when choose one control pattern, operation of other pattern is invalid, avoid the clash.
--Local meter display data: local meter can display 3 phases voltage, current, active power, frequency and so on.
Software Function
--Communication pattern: Intelligent control use photoelectric isolated RS485 interface connect to PC, with great anti-interference performance to make system control stable. Also user can use USB or RS232 through converter.
--Load pattern: Manual Load or Automatic Load.
--Manual Load: Input power, system will load according to preset power.
--Automatic load: user can preset power and length of working time of several load periods, as per 0%→25%→50%→75%→100% or 110% to make testing.
--Parallel testing: when several load bank work in parallel, use can make parallel testing via software, can display, record parameters of every load bank and whole system parameter of parallel operation.
--Real-time parameter: through software to display voltage, current, power, power factor, frequency and time, etc.
--Security monitoring and control: monitor working state of the load bank by watching software light, when abnormally stop and protect, it can show the reason.
--Data collection interval: the minimum data storage interval is two seconds.
--Data save and query: all the test data is saved in the software, easy to query in the history testing data.
--Graphical display: show real-time or history testing data, and support to print curve and graph as follows:
1) Graphs of real-time voltage, current, frequency and power; 2) Voltage graph
3) Current graph; 4) Power graph; 5) Frequency graph; 6) Power factor graph
--Data format: all the curves and graphs can be outputted as".doc"format, testing data can be outputted as ".xls" format, and can be printed.
Protection
--Emergency stop: you can press the Emergency Stop switch in the panel, when the load bank is locked in this state, it cannot add any load.
--Overvoltage protection: when input voltage is over the safe value, it can unload automatically and give an alarm.
--Short circuit protection: when short circuit, fuses in the load bank can insure to unload automatically.
--Overheating protection: when temperature is over the safe value, it can unload automatically and give an alarm.
--Fan interlock protection: load bank cannot add any load when working power of fan is off.
--Protection Buttons: There are buttons for some protection, when misinformation occurs or user has special needs, user can temporarily turn off the corresponding protection function.
--When control power cable is in incorrect phase sequence, fans of three phases will also work in right directions.
Technical Parameters
Technical Parameters |
Rating Voltage/Frequency |
AC 400V/50Hz, 3 phase 4 wire |
Max Load Power |
Resistive Load: 1250kW |
Load Step |
Resistive Load. 9 steps; 50,50,50,100,200,200,200,200,200kW |
Power Factor |
1 |
Load Tolerance(each step) |
±5% |
Load Tolerance(overall) |
±3% |
Display Precision |
0.5 class |
Control Power Supply |
AC380V/50Hz 3 phase 4 wire |
Wire Connection |
Load Power Supply Input--Copper bar (star connection)
Control power supply input--Connector bar |
Communication Interface |
RS485, RS232 |
Insulation Class |
F |
Working Mode |
Continuous Working |
Cooling |
Forced air cooling,Horizontal inlet air,Horizontal outlet |
Transportation |
Hoisting, there are lifting lug in top of casing |
Size |
Approximately; 1460*2800*2100
(Width *Length *Height) |
Weight |
Approximately; 1700kg |
Operating Environment Parameter |
Ambient Temperature |
-10ºC~+50ºC (14ºF~122ºF) |
Relative Humidity |
≤95% |
Altitude |
≤2500 meters |
Atmospheric Pressure |
86~106kPa |
Who we are
Hebei Kaixiang Electrical Technology Co., Ltd is a leading manufacturer in emergency power supply test & maintenance industry. Specialized in the design, R&D, manufacture of the high capacity AC & DC load bank, it owns the largest intelligent power supply testing equipment R & D centre in China. We offer one-stop solutions to generator set & battery & UPS power manufacturers. Our products are widely used in data centre, shipbuilding, offshore platform, state grid, nuclear power, hospital, communication, railway, war industry etc filed. We are strategy partner of many famous company, such as Cummins, Caterpillar, Kohler, Jiangnan Shipyard, CSSC,CSIC, State grid, China mobile, Tecent, Baidu, Sinopec, CETC etc. Some of our products have been exported to Singapore, Japan, United Kingdom, Saudi Arabia, Australia, South Korea, Thailand, Angola etc. Through years of development, "Triumph Load" already the first brand in power supply detection industry in China.
Why choosing us
The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
The most patent technology and scientific research awards gainer in China.
Advanced detection method and strict inspection procedure build the qualified quality.
Customized production meet the individual requirement.
Prompt delivery & excellent after sales service.
Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.