Dual Voltage Act220 440V-100kw Resistive Load Bank for Generator UPS Testing

Product Details
Customization: Available
Conditions
of Use:
Land Use
Usage: Common Units
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Dual Voltage Act220 440V-100kw Resistive Load Bank for Generator UPS Testing
  • Dual Voltage Act220 440V-100kw Resistive Load Bank for Generator UPS Testing
  • Dual Voltage Act220 440V-100kw Resistive Load Bank for Generator UPS Testing
  • Dual Voltage Act220 440V-100kw Resistive Load Bank for Generator UPS Testing
  • Dual Voltage Act220 440V-100kw Resistive Load Bank for Generator UPS Testing
  • Dual Voltage Act220 440V-100kw Resistive Load Bank for Generator UPS Testing
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Our Advantages
  • exhibition photoes
Overview

Basic Info.

Model NO.
With quick connections 100kw
Output Type
AC Three Phase
Cooling
Method
Air Cooled
Installation
Method
Portable
Generator
Type
Load Bank
Voltage
AC 220V 440V 240V 480V
Frequency
50Hz
Rated Power
100kw
Insulation Grade
F Class
Fan Working Voltage
AC110-240V 1-Phase/50Hz/60Hz
Weight
35kg
Transport Package
Wooden Case
Specification
SGS
Trademark
Triumph Load
Origin
Shijiazhuang, Hebei, China
HS Code
9030339000
Production Capacity
10000sets/Year

Packaging & Delivery

Package Size
67.00cm * 29.00cm * 60.00cm
Package Gross Weight
35.000kg

Product Description

Product Description

 

ACT240 480V Dual Voltage Load Bank 100kW 240V/480V Portable Generator & UPS Tester with Digital Display

Key Features & Benefits:  
Dual Voltage Operation - Test both 240V and 480V power sources with a single unit.  
100kW High Load Capacity - Ideal for industrial generators, data centers, and marine power systems.  
Adjustable Load Steps- Fine-tune resistance for accurate kW/kVA testing.  
Advanced Digital Display - Real-time monitoring of voltage, current, power, and temperature.  
Forced Air Cooling - Ensures stable operation under continuous 100kW load testing.  
Portable & Durable - Heavy-duty steel enclosure with easy-transport wheels.  
Safety Protections - Overload, short-circuit, and overheating protection for safe operation.  

 

Product Parameters

Convenient and light aluminium frame 100kw load Banks for Generator UPS Testing

ACT220V/440V-100kW Portable Load Bank
Rating Voltage/Frequency 220/440VAC 3 phase 3 wire, 50Hz/60Hz
Rated Power Resistive load: 100kW
Load Step Total 4 load steps:
5kW,10kW, 20 kW, 25 kW, 40kW. Min. step from 5kW .
PF(Power Factor) 1
Load Tolerance ±3%
Display Precision 0.5 class
Control Power External 110~240VAC/50~60Hz
Wire Connection Load power supply input--Quick plug
Control power supply input--3 pin socket
Communication Interface RS485
Insulation F
Duty cycle Continuous
Cooling Forced air cooling, horizontal air inlet & outlet
Transportation  Suitcase
Color  White /Dark /As customer required
Dimension About 666mm×292mm×597mm(L/W/H)
Weight    About 35kgs
Operating Environment Parameter
Workplace Indoor
Ambient Temperature -20ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤2500 meter
Atmospheric Pressure 86~106kPa
Brands of Main Components
   
PLC Siemens
Data processing software Kaixiang(self-developed)
Resistor Kaixiang(self-developed)

Detailed Photos

Pictures of Customized 100kW Load Bank AC for Generator Testing
Protection

  1. User can press the emergency stop button in the panel to unload immediately when the load bank is abnormal while working.
  2. Over-voltage Protection: Automatic load dump and give alarm when voltage is over safety thresholds.
  3. Over-current Protection: Automatic load dump and give alarm when current is over safety thresholds.
  4. Over-heat protection: Automatic load dump and give alarm when temperature is over safety thresholds.
  5. Protection button: there are some protection buttons can be switched off when false alarm or for special requirements.  
  6. Enclosure Ground Protection: the load bank with special ground protection terminal to avoid user under risk of electric shock hazard.

Dual Voltage Act220 440V-100kw Resistive Load Bank for Generator UPS TestingDual Voltage Act220 440V-100kw Resistive Load Bank for Generator UPS TestingDual Voltage Act220 440V-100kw Resistive Load Bank for Generator UPS TestingDual Voltage Act220 440V-100kw Resistive Load Bank for Generator UPS TestingDual Voltage Act220 440V-100kw Resistive Load Bank for Generator UPS Testing
 

Our Advantages

Why choosing us

  1. The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
  2. The most patent technology and scientific research awards gainer in China.
  3. Advanced detection method and strict inspection procedure build the qualified quality.
  4. Customized production meet the individual requirement.
  5. Prompt delivery & excellent after sales service.
  6. Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
  7. Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
  8. Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.

Data Processing Software Functions:
Communication type: through RS485 or USB interface.
Load mode: manual load or automatic load.
Manual load: input power and power factor.
Automatic load: User can set several periods of power and time, and in turn of 0%→25%→50%→75%→100% etc or other preset order (33%→66%→99%) to make automatic load testing.
Parallel testing: when several load banks parallel working, parameters of each load bank can be displayed and recorded, so do the final parameters of paralleling working.
Real-time parameter: Current, voltage, power, power factor, frequency, time, etc could be displayed by software.
Safety monitoring: User can know the working conditions of load bank through software indicating light. When in abnormal stop protection, software will indicate the reasons of stopping.
Data collection interval: the min saving interval is 2 seconds.
Data saving and in query: testing data could be saved in software, user can query at any time.
 Data display: it could display real-time data and history data; user can print voltage, current, frequency, power graphs and charts.
6.Applications:
- Generator load testing (diesel, gas, turbine)  
- UPS system validation(data centers, hospitals)  
-  marine power assurance  
- Renewable energy storage testing

 

exhibition photoes

 