• High and Low Voltage Load Bank Double Circuit
  • High and Low Voltage Load Bank Double Circuit
  • High and Low Voltage Load Bank Double Circuit
  • High and Low Voltage Load Bank Double Circuit
  • High and Low Voltage Load Bank Double Circuit
  • High and Low Voltage Load Bank Double Circuit

High and Low Voltage Load Bank Double Circuit

After-sales Service: 12 Months
Voltage: AC6.3kv/400V
Frequency: 50Hz
Resistive Power: 800W+250kw
Insulation Grade: F Class
Protection Grade: IP56
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC6.3KV-800KW/AC400V-250KW
Transport Package
Container
Trademark
Triumph Load
Origin
China

Product Description

High and Low Voltage Load Bank Double Circuit

1.Product Introduction

AC6.3KV 800KW+AC400V 250KW High and Low Voltage Load Bank Double Circuit

High voltage load bank,the optional voltage range is 6.6KV~35KV,can be directly used for large high voltage generator,

need not to be equipped with conventional step-down transformer.We can also provide regular load bank for high voltage 

equipment,need to use step-down transformer together.

The system consists of two separate circuits,AC6.3KV-800KW medium voltage load circuit and AC400-250KW low voltage load circuit. Two circuits can work individually at the same time,and  without interference.

Each circuit consists of measurement and control and load two parts, mainly including data acquisition system, automatically add and subtract load control system, heat dissipation device and auxiliary control part.

High and Low Voltage Load Bank Double CircuitHigh and Low Voltage Load Bank Double Circuit

2. AC6.3KV 800KW+AC400V 250KW High and Low Voltage Load Bank Double Circuit Application

Large generator system testing in ocean engineering, drilling facilities,ship construction etc field

Factory testing for generator, static voltage characteristic test, speed characteristic test;

Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test

Assist shipyard in mooring test,sea trial test

Assist with the acceptance of the vessel generator test

Eliminate the carbon deposition of generator

As the generator loading system

Periodic running test for standby generator

UPS inspection and maintenance

Ship battery charging/discharging system testing

The acceptance of new system and testing of servicing equipment

 

3. AC6.3KV 800KW+AC400V 250KW High and Low Voltage Load Bank Double Circuit System Chart
High and Low Voltage Load Bank Double Circuit


4. AC6.3KV 800KW+AC400V 250KW  High and Low Voltage Load Bank Double Circuit Technical  Specifications

 

Load System Parameters

Circuit 1   AC6.3KV 800KW

Rated Voltage 

and Frequency

AC 3 phase wire, 6.3KV/50Hz

MaximumLoad Power

Resistive Load: 800KW

Load Resolution

50KW,50KW,100KW,200KW,400KW 5Steps

Power Factor

1

Load Accuracy (per file)

± 5%

Load Accuracy (whole)

± 3%

Display Accuracy

0.5

Working Power

Around 10KW,the generator supply power

Wire Connection 

Connected by copper bar

Display Mode

LED multi-functional meter display voltage and current

Circuit 2   AC400V-250KW

Rated Voltage 

and Frequency

AC 3 phase wire, 400V/60Hz

Maximum Load Power

Resistive Load:250KW

Load Resolution

1,2,2,5,10,20,20,50,50,100KW 10Steps

Power Factor

1

Load Accuracy (per file)

± 5%

Load Accuracy (whole)

± 3%

Display Accuracy

0.5

Working Power

Around 5KW,the generator supply power

Wire Connection 

Connected by copper bar

Display Mode

LED multi-functional meter display voltage and current

Common Parameters

Insulation Class

F

Insulation Resistance to Earth

≥10MΩ

Protection Grade

IP56

Working Mode

Continuous working

Chassis Construction

Container package, with up to the top of the ladder, with inlet and 

outlet grilles and door protection

Enclosure

Container type,with a ladder, air inlet and outlet with mesh enclosure 

and protection door

Transportation

Hoisting, there are lifting lug in top of casing

Chassis Size

Approximately 6000mm × 2438mm × 2591mm (L × W × H)

Weight

Approximately 5500kg

Work environment parameters

Workplace

Coastal areas, outdoor work

Operating Temperature

- 25 ºC ~ + 6 0 ºC (lower limit of the instrument's temperature-10 ºC)

Relative Humidity

≤ 95%

Altitude

≤ 2500m

Atmospheric pressure

86 ~ 106kPa

 

5. AC6.3KV 800KW+AC400V 250KW High and Low Voltage Load Bank Double Circuit Overall Appearance
High and Low Voltage Load Bank Double Circuit
High and Low Voltage Load Bank Double Circuit

6.Why choosing us

  1. The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
  2. The most patent technology and scientific research awards gainer in China.
  3. Advanced detection method and strict inspection procedure build the qualified quality.
  4. Customized production meet the individual requirement.
  5. Prompt delivery & excellent after sales service.
  6. Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
  7. Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
  8. Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.

7.Contact Information
Kaixiang Electrical Technology Co., LTD.
Eric Zhang
ADD:79Wangshan Rd,Luquan District,Shijiazhuang,Hebei,050221,P.R.China
 
 
M.T.:+86 18937738282
Our service is beyond of products,but the feeling of customers

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.