• 400V 3300kVA Resistive Reactive Load Bank for Generator Commissioning
  • 400V 3300kVA Resistive Reactive Load Bank for Generator Commissioning
  • 400V 3300kVA Resistive Reactive Load Bank for Generator Commissioning
  • 400V 3300kVA Resistive Reactive Load Bank for Generator Commissioning

400V 3300kVA Resistive Reactive Load Bank for Generator Commissioning

Conditions
of Use:
Trailer Type, Marine, Land Use
Usage: Standby Unit, Common Units
Output Type: AC Three Phase
Cooling
Method:
Air Cooled
Installation
Method:
Fixed
Generator
Type:
Diesel Generator
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AC400-3300KVA
Voltage
380V,400V,415V,440V,480V,690V
Apparent Power
3300kVA
Resistive
2640kw
Reactive
1980kvar
Power Factor
0.8, 1
Frequency
50Hz or 60Hz
Min Step
1kw
Cooling
Air Cooled
Control
Local and Remote
Dimension
20FT Container
Weight
15tons
Warranty
12months
Transport Package
Container
Specification
ISO
Trademark
Triumph Load
Origin
Shijiazhuang, China
HS Code
903033900
Production Capacity
1000 Sets/ Year

Product Description

3300KVA Resistive Reactive Load Bank:

The ability to test critical power systems at voltages of 380V to 20kV using direct-connect, High Voltage Load Bank offers engineers flexibility, time savings, cost savings, space savings and simplicity. It mainly used to commission utility, oil & gas, and industrial power systems without the need for additional transformers and cabling.

Application of Resistive Reactive Load Bank

Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment

Technical Parameter

System Parameter

Rating voltage/frequency

400V, 3 phase 4 wire 50Hz

Max Load Power

Apparent Power: 3300KVA 

Resistive Load: 2640kW

Inductive Load: 1980KVAR

Load Resolution

Resistive Load: 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,200kW..... 

Reactive Load: 1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR,50KVAR, 100KVAR, 100KVAR, 200KVAR.....

Power Factor

0.8(lag)

Load Tolerance (each step)

±5%

Load Tolerance (overall)

±3%

Fan &Control Voltage

External 400VAC 3 phase 4 wire/50Hz  

Wire Connection

Load bank input--Copper bar (star coupling "Y")

Control power input--Connector-bar

Communication Interface

RS485,RS232

Insulation

F

Max Protection Grade

IP54

Duty Cycle

Continuous  

Cooling

Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling

Enclosure

Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door

Internal Lighting

Adequate internal lighting will be provided

Transportation

Hoisting, there are lifting lug in top of casing

Color

Grey RAL7035 or as required

Dimensions

About 6058mm×2350mm×2591mm(L×W×H)

Operating Environment Parameter

Workplace

 Outdoor  

Ambient Temperature

-10ºC~+50ºC

Relative Humidity

≤95%

Atmospheric Pressure

86~106kPa

 

400V 3300kVA Resistive Reactive Load Bank for Generator Commissioning
400V 3300kVA Resistive Reactive Load Bank for Generator Commissioning
400V 3300kVA Resistive Reactive Load Bank for Generator Commissioning
 

Send your message to this supplier