Electrical Load Bank 500kw Resistive Load Bank Testing Generator

Product Details
Customization: Available
After-sales Service: 12 Months
Warranty: 1 Year
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Electrical Load Bank 500kw Resistive Load Bank Testing Generator
  • Electrical Load Bank 500kw Resistive Load Bank Testing Generator
  • Electrical Load Bank 500kw Resistive Load Bank Testing Generator
  • Electrical Load Bank 500kw Resistive Load Bank Testing Generator
  • Electrical Load Bank 500kw Resistive Load Bank Testing Generator
  • Electrical Load Bank 500kw Resistive Load Bank Testing Generator
Find Similar Products
  • Overview
  • Product Description
  • Specification sheet
  • Certifications
Overview

Basic Info.

Model NO.
Resistive Load Bank 500kw
Max Diameter of Workpiece
1000mm
Mass Scope of Workpiece
<900kg
Type
Testing Equipment
Maxcapacity
>1000KN
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Computer Control
Weight
100-500Kg
Power Source
AC380V
Oil Cylinder Position
No
Color
Variety
Dimension
About 900mm*1100mm*1200mm
Load Tolerance
5%
Function
for Generator Testing
Cooling Type
Fan
Transport Package
Plywood Cases
Specification
500kw
Trademark
triumph load
Origin
China
HS Code
90303390
Production Capacity
100/Month

Packaging & Delivery

Package Size
123.00cm * 102.00cm * 168.00cm
Package Gross Weight
500.000kg

Product Description

Product Description

Electrical Load Bank 500kw Resistive Load Bank Testing Generator
PRODUCT ADVANTAGE
1.WITH SOFTWARE CONTROL AND LOCAL PANEL CONTROL.
2.WITH CASTORS FORKLIFT AND LIFTING LUG LOAD BANK, EASY TO TRANSPORT AND MOVE
3.WITH FAMOUS COMPONENTS, WHICH CAN ENSURE LOAD BANK QUALITY BETTER THAN OTHERS
4.LOAD BANK HAS MANY PROTECTION MODES, SUCH AS OVER VOLTAGE PROTECTION,OVER CURRENT PROTECTION,OVER HEAT PROTECTION,SHORT CIRCUIT PROTECTION,FAN CAPACITY PROTECTION,ENCLOSURE GROUNDING PROTECTION,EMERGENCY STOP ETC

 

Specification sheet

 

Specification
Technical Parameters
Rating Voltage/Frequency AC 400V/50Hz, 3 phase 4 Line
Max Load Power Resistive Load: 500kW
Load Step Resistive Load:11 steps; 1,2,2,5,10,10,20,50,100,100,200kW
Power Factor 1
Load Tolerance(each step) ±5%
Load Tolerance(overall) ±3%
Display Precision 0.5 class
Control Power Supply External 380VAC, 3phase 4wire 50Hz,
Wire Connection Load Power Supply Input--Copper bar (star connection)
Control power supply input--connect bar
Communication Interface RS485, RS232
Insulation Class F
Working Mode Continuous Working
Cooling Forced air cooling,Horizontal inlet air,Horizontal outlet
Transportation Hoisting, there are lifting lug in top of case and wheel castors in bottom
Color Orange(RAL2008)
Dimension  About 900mm*1100mm*1200mm(L×W×H)
Operating Environment Parameter
Ambient Temperature -20ºC~+50ºC 
Relative Humidity ≤95%
Altitude ≤2500 meters
Atmospheric Pressure 86~106kPa
Electrical Load Bank 500kw Resistive Load Bank Testing GeneratorElectrical Load Bank 500kw Resistive Load Bank Testing Generator
Main 10 Technology Advantages
Kaixiang company is in leading position in generator set testing and maintenance industry, besides general functions, its load bank has following unique advantages:
1. Testing Function: The load bank can do stable test, some can do transient test, and realize functions, such as setting, fluctuation, instant load, and instant unload.
2. Super Power Load: high load power density, large capacity of single set, parallel  running to finish super power testing, and realize tens of megawatts of power loading.
3. Accurate Data: with high precision data collection module and measuring meter, related equipment has passed the certification by CMA (China Metrology Accreditation) qualification testing institution, and ensure the reliability of data.
4. Flexible Control Mode: based on different using habit, several control mode as following can be choosed, local panel operation, remote box controlling, and intelligent software. 
5. Intelligent Load: after setting generator rated power in software, system realize rapid loading through preset proportion, automatically and continuously load multiple power value and common tests, like stepping, full load, and over load, so that improve working efficiency.
6. High Efficiency Data Management: display real-time testing data, generate form,  curve graph or report automatically, also can put data into storage. According to generator set No. set up testing file, support to query at any time, and improve data management efficiency.
7. Comprehensive Protection Function: multiple protection, like Over-heat Protection. Emergency Stop,Over-voltage Protection,Short Circuit and Insulation Protection,Enclosure Ground Protection, When in danger, automatically terminate the test and give alarm to protect safety of personnel and equipment.
8. Stable Running: with the latest generation control module as the core, a sharp rise in system response speed and anti-interference performance, avoid function failure in complex electrical environment, and ensure system running stably and reliably. 
9. New Load Bank Technology: using the international advanced AC load bank technology, overcome the old water bank defects, such as bear bumpy, unable to use when go to sea, realize Mooring Trial and Sea Trail, and simulate the real working condition of generator running.  
10. Mature Manufacturing Technology: load element using excellent anti-corrosion materials, waterproof insulation container packaging, suitable for adverse environment such as ocean. Internal layout is reasonable, air channel is clear, rapid heat emission, and satisfy continuous working need.
Certifications

LOAD BANK CE CERTIFICATE

Electrical Load Bank 500kw Resistive Load Bank Testing GeneratorElectrical Load Bank 500kw Resistive Load Bank Testing GeneratorElectrical Load Bank 500kw Resistive Load Bank Testing Generator
Electrical Load Bank 500kw Resistive Load Bank Testing GeneratorElectrical Load Bank 500kw Resistive Load Bank Testing GeneratorElectrical Load Bank 500kw Resistive Load Bank Testing GeneratorElectrical Load Bank 500kw Resistive Load Bank Testing Generator
Electrical Load Bank 500kw Resistive Load Bank Testing Generator


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier