10.5kv International Load Bank 2300kw load banks for Genset Testing
1. Product Introduction
High voltage load bank,the optional voltage range is 6.6KV~35KV,can be directly used for large high voltage generator,
need not to be equipped with conventional step-down transformer. We can also provide regular load bank for high voltage
equipment,need to use step-down transformer together.
2. 10.5kv International Load Bank 2300kw load banks for Genset Testing Application
Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection
test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
3. 10.5kv International Load Bank 2300kw load banks for Genset Testing
4. 10.5kV Vehicular Load Bank 2300KW Genset Testing Working Environment
Altitute:≤2500m
Temperature:-20°C~50°C
Humidity:≤95%RH
Working Mode:Continuous work(>6hours continuous long-term work per day)
5. 10.5kv International Load Bank 2300kw load banks for Genset Testing Technical Specifications
Technical Parameter
System Parameters (Single set) |
|
Rated Voltage/ Frequency |
AC10.5kV/50Hz, 3 phases 3 wire
|
Installer Capacity |
2300kW |
Step Load |
100KW, 200KW, 400KW, 800KW, 800KW 5steps |
Power Factor (PF) |
1 |
Load Tolerance |
±5% |
Display Precision |
0.5 grade |
Control Power Supply |
AC380V/50Hz, 3 phases 4 wire |
Insulation |
F |
Max Protection Grade |
IP54 |
Working Mode |
Continuous |
Cooling |
Forced air cooling, Horizontal inlet air, Vertical cooling |
Casing Structure |
Standard 20 feet container, with a ladder to top |
Transportation |
Hoisting, there are lifting lugs in top of casing |
Dimension |
6058mm×2438 mm×2591mm |
Weight |
About 8000kg |
Working Environment Parameters |
|
Ambient Temperature |
-20ºC~+55ºC |
Relative Humidity |
≤95% |
Altitude |
≤2500 meters |
Atmospheric Pressure |
86~106kPa |
Working Temperature |
Temperature inside container: less than 35ºC,forced-air cooling |
(1) Stable-state Test: load power in rated range, measure generator steady-state 3 phase voltage, current, active power, reactive power, apparent power, power factor, frequency, and running time.
(2) One-key load/unload: no mattery using software control or manual control, can set loading power first, then press master load switch, this avoid the load fluctuation.
(3) Setting Test: can catch the max and min setting value of voltage and frequency, and calculate the relative setting up and down range of voltage and frequency and adjustment rate within 100 seconds setting time.
(4) Fluctuation Test: catch the max and min fluctuating value of voltage and frequency, and calculate steady-state frequency band, steady-state voltage deviation, voltage modulation, fluctuation rate and frequency in 60 seconds fluctuation time.
(5) Transient Test (Instant Load Test): sample interval is 40μs,system catch the transient max and min value and recovery time of voltage, current, and frequency, and calculate instant load transient voltage deviation and instant load transient frequency deviation.
(6) Transient Test (Instant Unload Test): sample interval is 40μs,system catch the transient max and min value and recovery time of voltage, current and frequency, and calculate instant unload transient voltage deviation and instant unload transient frequency deviation.
(7) Harmonic Analysis: It can analysis 2~50 harmonic content and total harmonic content in voltage and current at same time.
(8) Record Wave Analysis: 5 patterns for recording voltage real-time waveform, and the record time is 4~ 280 seconds and accurately sampling at 128 points in a wave cycle at most.
6. 10.5kV Vehicular Load Bank 2300KW Genset Testing Overall Appearance